Meta-analysis of the outcomes of intramedullary nailing and plate fixation of humeral shaft fractures

被引:44
作者
Liu, Guo-dong [1 ]
Zhang, Qing-gang [2 ]
Ou, Shan [3 ]
Zhou, Le-shun [3 ]
Fei, Jun [4 ]
Chen, Hong-wei [5 ]
Nan, Guo-xin [6 ]
Gu, Jian-wen [7 ]
机构
[1] Third Mil Med Univ, Daping Hosp, Inst Surg Res, Dept 8, Chongqing 400042, Peoples R China
[2] Tongji Univ, Sch Med, Peoples Hosp Shanghai 10, Dept Orthoped, Shanghai 200072, Peoples R China
[3] Chengdu Mil Command, Gen Hosp, Dept Anesthesiol, Chengdu 610083, Sichuan, Peoples R China
[4] Third Mil Med Univ, Daping Hosp, Inst Surg Res, Traumat Ctr, Chongqing 400042, Peoples R China
[5] Cent Hosp Yiwu City, Dept Orthoped, Yiwu 322000, Zhejiang, Peoples R China
[6] Chongqing Med Univ, Childrens Hosp, Dept Orthoped 2, Chongqing 400014, Peoples R China
[7] Chengdu Mil Command, Gen Hosp, Dept Neurosurg, Chengdu 610083, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Humeral shaft fracture; Intramedullary nailing; Steel plate; Meta-analysis; DYNAMIC COMPRESSION PLATE;
D O I
10.1016/j.ijsu.2013.08.002
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: The purpose of this study is to compare the outcomes of intramedullary nailing and plate fixation in the treatment of humeral shaft fractures using meta-analysis. Methods: PubMed, MEDLINE, EMBASE, the Cochrane Controlled Clinical Trials Register (CCTR) databases were searched for studies that investigated the efficacy of intramedullary nailing and plate fixation in the management of humeral shaft fractures. Delayed healing rate, nonunion, postoperative infection and radial nerve paralysis were key outcomes of interest. Data were searched within the time period of July 1990 through September 2012. The statistical software RevMan 5.0 was used to analyze the statistical significance of the results. Results: Total 459 cases of patients in 10 literature, including 231 cases of plate group and 228 cases of the intramedullary nailing groups were collected. The results of meta-analysis showed that delayed healing rate of humeral shaft fractures was lower in plate fixation compared with intramedullary nailing (RR = 2.64, 95% CI (1.08, 6.49), P < 0.05). No statistically significant difference in nonunion, postoperative infections, radial nerve paralysis and other complications was identified between nailing and plate fixation groups (P > 0.05). Conclusions: In general, the effect size of intramedullary nailing may be comparable to that of plate fixation in the terms of nonunion, postoperative infections, radial nerve paralysis. The only slightly difference was identified in the event of delayed healing rate. (C) 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:864 / 868
页数:5
相关论文
共 23 条
[21]   Nailing versus plating in humerus shaft fractures: A prospective comparative study [J].
Singisetti, Kiran ;
Ambedkar, M. .
INTERNATIONAL ORTHOPAEDICS, 2010, 34 (04) :571-576
[22]  
Tsai CH, 2009, Int Orthop, V33, P463, DOI [10.1007/s00264-008-0537-8, DOI 10.1007/S00264-008-0537-8]
[23]  
张应鹏, 2005, [第一军医大学学报, Journal of First Military Medical University], V25, P906