Long-term kinematic analysis of cervical spine after single-level implantation of Bryan cervical disc prosthesis

被引:39
|
作者
Ryu, Won Hyung A. [1 ]
Kowalczyk, Izabela [2 ,3 ]
Duggal, Neil [1 ,2 ,3 ,4 ]
机构
[1] Univ Western Ontario, Schulich Sch Med & Dent, London, ON, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[3] Univ Western Ontario, Ctr Funct & Metab Mapping, Robarts Res Inst, London, ON, Canada
[4] Univ Western Ontario, Univ Hosp, London Hlth Sci Ctr, Dept Clin Neurol Sci,Div Neurosurg, London, ON N6A 5A5, Canada
关键词
Cervical arthroplasty; Kinematics; Total disc replacement; Bryan disc; Cervical disc replacement; INTERMEDIATE FOLLOW-UP; CLINICAL-TRIAL; SEGMENTAL MALALIGNMENT; INTERVERTEBRAL MOTION; ANTERIOR DISKECTOMY; ARTHROPLASTY; FUSION; DISEASE; REPLACEMENT; MULTICENTER;
D O I
10.1016/j.spinee.2013.02.046
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Cervical arthroplasty theoretically reduces the risk of adjacent level disc degeneration and segmental instability that may be seen after a cervical fusion. An essential argument in confirming the utility of cervical arthroplasty is long-term confirmation that cervical disc replacements can maintain physiological kinematics at the index and adjacent levels. PURPOSE: The purpose of this in vivo prospective study was to characterize the long-term segmental kinematic outcomes after cervical arthroplasty. STUDY DESIGN/SETTING: Prospective cohort study. PATIENT SAMPLE: Twenty patients with a 5-year clinical follow-up who underwent anterior cervical discectomy with insertion of the Bryan cervical disc. OUTCOME MEASURES: Physiological measures (kinematic analysis of lateral neutral, flexion, and extension radiographic imaging). METHODS: Twenty consecutive patients with degenerative disc disease were followed with regular radiographic imaging after implantation of the Bryan cervical disc prosthesis. Lateral neutral, flexion, and extension radiographs (n=240) were analyzed using Quantitative Motion Analysis software (Medical Metrics, Inc., Houston, TX, USA) to measure the biomechanical profile at the index level and adjacent levels up to 5 years after surgery. Parameters collected included range of motion (ROM), functional spinal unit (FSU) angle, anterior and posterior disc heights, sagittal translation, and center of rotation (COR). RESULTS: Biomechanics of the implanted artificial cervical disc was maintained up to 5 years with no significant changes in ROM, FSU angle, disc height, sagittal translation, and COR values when compared with early postoperative performance. Artificial discs were able to adequately restore and maintain preoperative kinematics. Early differences seen in disc height and FSU angle did not change during the duration of follow-up. No significant kyphotic changes or decrease in ROM were seen at the adjacent spinal levels. CONCLUSIONS: The Bryan cervical disc prosthesis provides for a durable solution for functional spinal motion at the operated level and maintained the preoperative kinematics at adjacent levels at the 5-year follow-up. Crown Copyright (C) 2013 Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:628 / 634
页数:7
相关论文
共 50 条
  • [21] Comparing the postoperative results of single-level anterior cervical discectomy and fusion, cervical disc prosthesis and minimal invasive posterior cervical disc surgery
    Sertbas, Idris
    Karatay, Mete
    BRITISH JOURNAL OF NEUROSURGERY, 2020, 34 (06) : 704 - 709
  • [22] Anterior Surgical Management of Single-Level Cervical Disc Disease
    Lewis, Daniel J.
    Attiah, Mark A.
    Malhotra, Neil R.
    Burnett, Mark G.
    Stein, Sherman C.
    SPINE, 2014, 39 (25) : 2084 - 2092
  • [23] Cervical spine biomechanics following implantation of a disc prosthesis
    Galbusera, Fabio
    Bellini, Chiara M.
    Raimondi, Manuela T.
    Fornari, Maurizio
    Assietti, Roberto
    MEDICAL ENGINEERING & PHYSICS, 2008, 30 (09) : 1127 - 1133
  • [24] Local and global subaxial cervical spine biomechanics after single-level fusion or cervical arthroplasty
    Michael A. Finn
    Darrel S. Brodke
    Michael Daubs
    Alpesh Patel
    Kent N. Bachus
    European Spine Journal, 2009, 18 : 1520 - 1527
  • [25] Cervical spine kinematics after anterior cervical discectomy with or without implantation of a mobile cervical disc prosthesis; an RCT
    Boselie, Toon F. M.
    van Mameren, Henk
    de Bie, Rob A.
    van Santbrink, Henk
    BMC MUSCULOSKELETAL DISORDERS, 2015, 16
  • [26] Cervical spine kinematics after anterior cervical discectomy with or without implantation of a mobile cervical disc prosthesis; an RCT
    Toon FM Boselie
    Henk van Mameren
    Rob A de Bie
    Henk van Santbrink
    BMC Musculoskeletal Disorders, 16
  • [27] In vivo analysis of cervical kinematics after implantation of a minimally constrained cervical artificial disc replacement
    Koller, Heiko
    Meier, Oliver
    Zenner, Juliane
    Mayer, Michael
    Hitzl, Wolfgang
    EUROPEAN SPINE JOURNAL, 2013, 22 (04) : 747 - 758
  • [28] Single-level cervical disc arthroplasty in the spine with reversible kyphosis: A finite element study
    Hu, Xu
    Jiang, Majiao
    Hong, Ying
    Rong, Xin
    Huang, Kangkang
    Liu, Hao
    Pu, Dan
    Wang, Beiyu
    JOR SPINE, 2022, 5 (02):
  • [29] Vertebral body split fracture after a single-level cervical total disc replacement Case report
    Tu, Tsung-Hsi
    Wu, Jau-Ching
    Fay, Li-Yu
    Ko, Chin-Chu
    Huang, Wen-Cheng
    Cheng, Henrich
    JOURNAL OF NEUROSURGERY-SPINE, 2012, 16 (03) : 231 - 235
  • [30] Investigating the 7-Year Cost-Effectiveness of Single-Level Cervical Disc Replacement Compared to Anterior Cervical Discectomy and Fusion
    McAnany, Steven J.
    Merrill, Robert K.
    Overley, Samuel C.
    Kim, Jun S.
    Brochin, Robert L.
    Qureshi, Sheeraz A.
    GLOBAL SPINE JOURNAL, 2018, 8 (01) : 32 - 39