Fifty Years of Technological Innovation Potential and Limitations of Current Technologies in Abdominal Magnetic Resonance Imaging and Computed Tomography

被引:25
作者
Attenberger, Ulrike I. [1 ]
Morelli, John [2 ]
Budjan, Johannes [1 ]
Henzler, Thomas [1 ]
Sourbron, Steven [3 ]
Bock, Michael [4 ]
Riffel, Philipp [1 ]
Hernando, Diego [5 ]
Ong, Melissa M. [1 ]
Schoenberg, Stefan O. [1 ]
机构
[1] Heidelberg Univ, Univ Med Ctr Mannheim, Inst Clin Radiol & Nucl Med, Med Fac Mannheim, D-68167 Mannheim, Germany
[2] St Johns Med Ctr, Tulsa, OK USA
[3] Univ Leeds, Fac Med & Hlth, Div Biomed Imaging, Leeds, W Yorkshire, England
[4] Univ Freiburg, Med Ctr, Med Phys Dept Radiol, Freiburg, Germany
[5] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
关键词
abdominal imaging; review; potentials and limitations; FATTY LIVER-DISEASE; GLOMERULAR-FILTRATION-RATE; RENAL-CELL CARCINOMA; DUAL-ENERGY CT; DIFFUSION-WEIGHTED MRI; CONTRAST-ENHANCED MRI; PATLAK PLOT TECHNIQUE; LEVEL-DEPENDENT MRI; COMPUTED-TOMOGRAPHY; BOLD-MRI;
D O I
10.1097/RLI.0000000000000173
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance imaging (MRI) has become an important modality for the diagnosis of intra-abdominal pathology. Hardware and pulse sequence developments have made it possible to derive not only morphologic but also functional information related to organ perfusion (dynamic contrast-enhanced MRI), oxygen saturation (blood oxygen level dependent), tissue cellularity (diffusion-weighted imaging), and tissue composition (spectroscopy). These techniques enable a more specific assessment of pathologic lesions and organ functionality. Magnetic resonance imaging has thus transitioned from a purely morphologic examination to a modality from which image-based disease biomarkers can be derived. This fits well with several emerging trends in radiology, such as the need to accurately assess response to costly treatment strategies and the need to improve lesion characterization to potentially avoid biopsy. Meanwhile, the cost-effectiveness, availability, and robustness of computed tomography (CT) ensure its place as the current workhorse for clinical imaging. Although the lower soft tissue contrast of CT relative to MRI is a long-standing limitation, other disadvantages such as ionizing radiation exposure have become a matter of public concern. Nevertheless, recent technical developments such as dual-energy CT or dynamic volume perfusion CT also provide more functional imaging beyond morphology. The aim of this article was to review and discuss the most important recent technical developments in abdominal MRI and state-of-the-art CT, with an eye toward the future, providing examples of their clinical utility for the evaluation of hepatic and renal pathologies.
引用
收藏
页码:584 / 593
页数:10
相关论文
共 119 条
  • [21] Comparison of 1.5 and 3 T BOLD MR to Study Oxygenation of Kidney Cortex and Medulla in Human Renovascular Disease
    Gloviczki, Monika L.
    Glockner, James
    Gomez, Sabas I.
    Romero, Juan C.
    Lerman, Lilach O.
    McKusick, Michael
    Textor, Stephen C.
    [J]. INVESTIGATIVE RADIOLOGY, 2009, 44 (09) : 566 - 571
  • [22] Computed Tomography Perfusion Imaging for Therapeutic Assessment Has It Come of Age as a Biomarker in Oncology?
    Goh, Vicky
    Ng, Quan Sing
    Miles, Ken
    [J]. INVESTIGATIVE RADIOLOGY, 2012, 47 (01) : 2 - 4
  • [23] Diffusion-weighted MRI in inflammatory renal lesions: all that glitters is not RCC!
    Goyal, Ankur
    Sharma, Raju
    Bhalla, Ashu S.
    Gamanagatti, Shivanand
    Seth, Amlesh
    [J]. EUROPEAN RADIOLOGY, 2013, 23 (01) : 272 - 279
  • [24] Single-Phase Dual- Energy CT Allows for Characterization of Renal Masses as Benign or Malignant
    Graser, Anno
    Becker, Christoph R.
    Staehler, Michael
    Clevert, Dirk A.
    Macari, Michael
    Arndt, Niko
    Nikolaou, Konstantin
    Sommer, Wieland
    Stief, Christian
    Reiser, Maximilian F.
    Johnson, Thorsten R. C.
    [J]. INVESTIGATIVE RADIOLOGY, 2010, 45 (07) : 399 - 405
  • [25] Dual-Energy CT in Patients Suspected of Having Renal Masses: Can Virtual Nonenhanced Images Replace True Nonenhanced Images?
    Graser, Anno
    Johnson, Thorsten R. C.
    Hecht, Elizabeth M.
    Becker, Christoph R.
    Leidecker, Christianne
    Staehler, Michael
    Stief, Christian G.
    Hildebrandt, Henriette
    Godoy, Myrna C. B.
    Finn, Myra E.
    Stepansky, Flora
    Reiser, Maximilian F.
    Macari, Michael
    [J]. RADIOLOGY, 2009, 252 (02) : 433 - 440
  • [26] Dual energy CT: preliminary observations and potential clinical applications in the abdomen
    Graser, Anno
    Johnson, Thorsten R. C.
    Chandarana, Hersh
    Macari, Michael
    [J]. EUROPEAN RADIOLOGY, 2009, 19 (01) : 13 - 23
  • [27] Measurement of single-kidney glomerular filtration rate using a contrast-enhanced dynamic gradient-echo sequence and the Rutland-Patlak plot technique
    Hackstein, N
    Heckrodt, J
    Rau, WS
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (06) : 714 - 725
  • [28] Measuring single-kidney glomerular filtration rate on single-detector helical CT using a two-point Patlak plot technique in patients with increased interstitial space
    Hackstein, N
    Bauer, J
    Hauck, EW
    Ludwig, M
    Krämer, HJ
    Rau, WS
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (01) : 147 - 156
  • [29] In vivo characterization of the liver fat 1H MR spectrum
    Hamilton, Gavin
    Yokoo, Takeshi
    Bydder, Mark
    Cruite, Irene
    Schroeder, Michael E.
    Sirlin, Claude B.
    Middleton, Michael S.
    [J]. NMR IN BIOMEDICINE, 2011, 24 (07) : 784 - 790
  • [30] Effect of PRESS and STEAM Sequences on Magnetic Resonance Spectroscopic Liver Fat Quantification
    Hamilton, Gavin
    Middleton, Michael S.
    Bydder, Mark
    Yokoo, Takeshi
    Schwimmer, Jeffrey B.
    Kono, Yuko
    Patton, Heather M.
    Lavine, Joel E.
    Sirlin, Claude B.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (01) : 145 - 152