Fifty Years of Technological Innovation Potential and Limitations of Current Technologies in Abdominal Magnetic Resonance Imaging and Computed Tomography

被引:25
作者
Attenberger, Ulrike I. [1 ]
Morelli, John [2 ]
Budjan, Johannes [1 ]
Henzler, Thomas [1 ]
Sourbron, Steven [3 ]
Bock, Michael [4 ]
Riffel, Philipp [1 ]
Hernando, Diego [5 ]
Ong, Melissa M. [1 ]
Schoenberg, Stefan O. [1 ]
机构
[1] Heidelberg Univ, Univ Med Ctr Mannheim, Inst Clin Radiol & Nucl Med, Med Fac Mannheim, D-68167 Mannheim, Germany
[2] St Johns Med Ctr, Tulsa, OK USA
[3] Univ Leeds, Fac Med & Hlth, Div Biomed Imaging, Leeds, W Yorkshire, England
[4] Univ Freiburg, Med Ctr, Med Phys Dept Radiol, Freiburg, Germany
[5] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
关键词
abdominal imaging; review; potentials and limitations; FATTY LIVER-DISEASE; GLOMERULAR-FILTRATION-RATE; RENAL-CELL CARCINOMA; DUAL-ENERGY CT; DIFFUSION-WEIGHTED MRI; CONTRAST-ENHANCED MRI; PATLAK PLOT TECHNIQUE; LEVEL-DEPENDENT MRI; COMPUTED-TOMOGRAPHY; BOLD-MRI;
D O I
10.1097/RLI.0000000000000173
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance imaging (MRI) has become an important modality for the diagnosis of intra-abdominal pathology. Hardware and pulse sequence developments have made it possible to derive not only morphologic but also functional information related to organ perfusion (dynamic contrast-enhanced MRI), oxygen saturation (blood oxygen level dependent), tissue cellularity (diffusion-weighted imaging), and tissue composition (spectroscopy). These techniques enable a more specific assessment of pathologic lesions and organ functionality. Magnetic resonance imaging has thus transitioned from a purely morphologic examination to a modality from which image-based disease biomarkers can be derived. This fits well with several emerging trends in radiology, such as the need to accurately assess response to costly treatment strategies and the need to improve lesion characterization to potentially avoid biopsy. Meanwhile, the cost-effectiveness, availability, and robustness of computed tomography (CT) ensure its place as the current workhorse for clinical imaging. Although the lower soft tissue contrast of CT relative to MRI is a long-standing limitation, other disadvantages such as ionizing radiation exposure have become a matter of public concern. Nevertheless, recent technical developments such as dual-energy CT or dynamic volume perfusion CT also provide more functional imaging beyond morphology. The aim of this article was to review and discuss the most important recent technical developments in abdominal MRI and state-of-the-art CT, with an eye toward the future, providing examples of their clinical utility for the evaluation of hepatic and renal pathologies.
引用
收藏
页码:584 / 593
页数:10
相关论文
共 119 条
  • [1] Assessment of Chronic Pancreatitis: Utility of Diffusion-weighted MR Imaging with Secretin Enhancement
    Akisik, M. Fatih
    Aisen, Alex M.
    Sandrasegaran, Kumar
    Jennings, S. Gregory
    Lin, Chen
    Sherman, Stuart
    Lin, John A.
    Rydberg, Magnus
    [J]. RADIOLOGY, 2009, 250 (01) : 103 - 109
  • [2] Glomerular filtration rate: Assessment with dynamic contrast-enhanced MRI and a cortical-compartment model in the rabbit kidney
    Annet, L
    Hermoye, L
    Peeters, F
    Jamar, F
    Dehoux, JP
    Van Beers, BE
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (05) : 843 - 849
  • [3] Barral M, 2013, Diagn Interv Imaging, V94, P619, DOI 10.1016/j.diii.2013.02.011
  • [4] Quantitative assessment of rat kidney function by measuring the clearance of the contrast agent Gd(DOTA) using dynamic MRI
    Baumann, D
    Rudin, M
    [J]. MAGNETIC RESONANCE IMAGING, 2000, 18 (05) : 587 - 595
  • [5] Prevalence of and risk factors for nonalcoholic fatty liver disease: The Dionysos Nutrition and Liver Study
    Bedogni, G
    Miglioli, L
    Masutti, F
    Tiribelli, C
    Marchesini, G
    Bellentani, S
    [J]. HEPATOLOGY, 2005, 42 (01) : 44 - 52
  • [6] Estimates of Glomerular Filtration Rate From MR Renography and Tracer Kinetic Models
    Bokacheva, Louisa
    Rusinek, Henry
    Zhang, Jeff L.
    Chen, Qun
    Lee, Vivian S.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (02) : 371 - 382
  • [7] Relaxation effects in the quantification of fat using gradient echo imaging
    Bydder, Mark
    Yokoo, Takeshi
    Hamilton, Gavin
    Middleton, Michael S.
    Chavez, Alyssa D.
    Schwimmer, Jeffrey B.
    Lavine, Joel E.
    Sirlin, Claude B.
    [J]. MAGNETIC RESONANCE IMAGING, 2008, 26 (03) : 347 - 359
  • [8] Charles-Edwards Elizabeth M, 2006, Cancer Imaging, V6, P135, DOI 10.1102/1470-7330.2006.0021
  • [9] Study of 320-Slice Dynamic Volume CT Perfusion in Different Pathologic Types of Kidney Tumor: Preliminary Results
    Chen, Chao
    Liu, Qi
    Hao, Qiang
    Xu, Bing
    Ma, Chao
    Zhang, Huojun
    Shen, Qianjin
    Lu, Jianping
    [J]. PLOS ONE, 2014, 9 (01):
  • [10] Subtype Differentiation of Renal Cell Carcinoma Using Diffusion-Weighted and Blood Oxygenation Level-Dependent MRI
    Choi, Youn Ah
    Kim, Chan Kyo
    Park, Sung Yoon
    Cho, Seong Whi
    Park, Byung Kwan
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (01) : W78 - W84