Development of a paper microfluidic surface enhanced Raman scattering assay for cardiac troponin I

被引:0
|
作者
Tu, Dandan [1 ,4 ]
Dean, John [1 ,4 ]
Holderby, Allison [2 ,4 ]
Schechinger, Monika [1 ,4 ]
Cote, Gerard L. [1 ,3 ,4 ]
机构
[1] Texas A&M Univ, Dept Biomed Engn, College Stn, TX 77843 USA
[2] Texas A&M Univ, Dept Chem, College Stn, TX 77843 USA
[3] Texas A&M Univ, Texas A&M Engn Expt Stn Ctr Remote Hlth Technol &, Dept Biomed Engn, College Stn, TX 77843 USA
[4] Engn Res Ctr ERC Precise Adv Technol & Hlth Syst, College Stn, TX 77843 USA
来源
OPTICAL DIAGNOSTICS AND SENSING XX: TOWARD POINT-OF-CARE DIAGNOSTICS | 2020年 / 11247卷
关键词
Point-of-care (POC) testing; Surface-enhanced Raman spectroscopy; Cardiovascular disease; Paper microfluidic device; IMMUNOASSAY; GROWTH;
D O I
10.1117/12.2544558
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The accurate and rapid diagnosis of myocardial infarction (MI) is essential to implement timely and definitive treatment to the patient. Cardiac Troponin I (cTnI) has been widely used as a biomarker for early diagnosis of MI. Point-of-care (POC) testing is favored because it can provide timely results when the patient is first encountered (e.g. ambulance, clinic, or emergency department). However, the clinical cut-off of cTnI for diagnosis of MI is in the pico- to femto-molar range (i.e. 0.01-0.1 ng/ml). Thus, a sensitive sensing system is needed to quantitively measure cTnI at the POC. Surface-enhanced Raman spectroscopy (SERS) is a sensitive optical technique that can be used to measure trace analytes in a sample. Moreover, paper-based sensing systems have demonstrated potential as a platform to implement assays, especially at the POC. This research describes the development of a paper-based SERS assay for detection of cTnI in the physiological relevant range. Aptamer is used in the assay for recognizing the cTnI in a sample. SERS is used to sensitively transduce the sensing signal from the assay. A handheld Raman spectrometer is used to measure the SERS signal. By measuring the change in the SERS signal, the concentration of target molecule is quantitatively determined. Moreover, spectral processing techniques are used to evaluate their effect on signal-to-noise ratio as well as sensitivity of the assay. Results showed the designed sensing system can be used to measure cTnI (0-0.5 ng/mL) in standard buffer solutions.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Aptamer-based surface-enhanced resonance Raman scattering assay on a paper fluidic platform for detection of cardiac troponin I
    Tu, Dandan
    Holderby, Allison
    Cote, Gerard L.
    JOURNAL OF BIOMEDICAL OPTICS, 2020, 25 (09)
  • [2] Development of a miRNA surface-enhanced Raman scattering assay using benchtop and handheld Raman systems
    Schechinger, Monika
    Marks, Haley
    Locke, Andrea
    Choudhury, Mahua
    Cote, Gerard
    JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (01)
  • [3] Antibiotic Susceptibility Test with Surface-Enhanced Raman Scattering in a Microfluidic System
    Chang, Kai-Wei
    Cheng, Ho-Wen
    Shiue, Jessie
    Wang, Juen-Kai
    Wang, Yuh-Lin
    Huang, Nien-Tsu
    ANALYTICAL CHEMISTRY, 2019, 91 (17) : 10988 - 10995
  • [4] Postmortem Analysis of Cardiac Troponin I by High-Sensitivity Troponin I Assay
    Hafiz, W. R. Wan Mohammad
    Aliaa, B. izzatul
    Swarhib, S. mohamed
    Faridah, M. N.
    MEDICINE AND HEALTH, 2025, 20 (01): : 328 - 339
  • [5] Surface plasmon-enhanced fluorescence immunosensor for monitoring cardiac troponin I
    Toma, Koji
    Oishi, Koki
    Iitani, Kenta
    Arakawa, Takahiro
    Mitsubayashi, Kohji
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 368
  • [6] Surface-enhanced Raman scattering studies on immunoassay
    Xu, SP
    Ji, XH
    Xu, WQ
    Zhao, B
    Dou, XM
    Bai, YB
    Ozaki, Y
    JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (03)
  • [7] Skeletal troponin I cross-reactivity in different cardiac troponin I assay versions
    Hyytia, Heidi
    Heikkila, Taina
    Hedberg, Pirjo
    Puolakanaho, Tarja
    Pettersson, Kim
    CLINICAL BIOCHEMISTRY, 2015, 48 (4-5) : 313 - 317
  • [8] Multiplexed microfluidic surface-enhanced Raman spectroscopy
    Abu-Hatab, Nahla A.
    John, Joshy F.
    Oran, Jenny M.
    Sepaniak, Michael J.
    APPLIED SPECTROSCOPY, 2007, 61 (10) : 1116 - 1122
  • [9] Recent Development of Cardiac Troponin I Detection
    Han, Xu
    Li, Shanghao
    Peng, Zhili
    Othman, Abdelhameed M.
    Leblanc, Roger
    ACS SENSORS, 2016, 1 (02): : 106 - 114
  • [10] Paper based point of care immunosensor for the impedimetric detection of cardiac troponin I biomarker
    Vasantham, Shreyas
    Alhans, Ruby
    Singhal, Chaitali
    Nagabooshanam, Shalini
    Nissar, Sumaya
    Basu, Tinku
    Ray, Sekhar C.
    Wadhwa, Shikha
    Narang, Jagriti
    Mathur, Ashish
    BIOMEDICAL MICRODEVICES, 2019, 22 (01)