Measuring anesthesia in children using the EEG

被引:43
作者
Davidson, AJ
机构
[1] Royal Childrens Hosp, Dept Anaesthesia & Pain Management, Parkville, Vic 3052, Australia
[2] Univ Melbourne, Dept Pharmacol, Melbourne, Vic, Australia
[3] Murdoch Childrens Res Inst, Melbourne, Vic, Australia
关键词
anesthesia; arousal; electroencephalograph;
D O I
10.1111/j.1460-9592.2006.01877.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Advances in electroencephalogram (EEG) processing have produced new interest in measuring anesthesia using the EEG. There are a number of EEG-based anesthesia 'depth' monitors now available and their use in pediatric anesthesia is increasing. Although these monitors have been extensively studied in adults, there are relatively few studies examining their validity or use in children. To some extent we must rely on adult data. However, extrapolation of data from adults to children requires an in depth understanding of the physiology behind the data. The first question is what is being measured. What is anesthesia? A model of anesthesia has several components with arousal as a core component. Arousal can be linked to clinical observations, and correlates with anatomical and physiological studies. The EEG has characteristics that fairly consistently change with arousal during anesthesia, but the relationship between arousal and the EEG is imprecise and drug dependent. This relationship is the basis for using the EEG to measure anesthesia and provides only an indirect measure of consciousness and memory formation. A good understanding of how the EEG is related to anesthesia is essential when interpreting the EEG during anesthesia, and especially when extending the use of the EEG to measure anesthesia in children. Physiological studies in adults and children indicate that EEG-derived anesthesia depth monitors can provide an imprecise and drug-dependent measure of arousal. Although the outputs from these monitors do not closely represent any true physiological entity, they can be used as guides for anesthesia and in so doing have improved outcomes in adults. In older children the physiology, anatomy and clinical observations indicate the performance of the monitors may be similar to that in adults, although the clinical relevance of outcomes may be different. In infants their use cannot yet be supported in theory or in practice.
引用
收藏
页码:374 / 387
页数:14
相关论文
共 100 条
[61]   Synaptic mechanisms of thiopental-induced alterations in synchronized cortical activity [J].
Lukatch, HS ;
MacIver, MB .
ANESTHESIOLOGY, 1996, 84 (06) :1425-1434
[62]   Thiopental uncouples hippocampal and cortical synchronized electroencephalographic activity [J].
MacIver, MB ;
Mandema, JW ;
Stanski, DR ;
Bland, BH .
ANESTHESIOLOGY, 1996, 84 (06) :1411-1424
[63]   ELECTROENCEPHALOGRAPHY IN ANESTHESIOLOGY [J].
MARTIN, JT ;
FAULCONER, A ;
BICKFORD, RG .
ANESTHESIOLOGY, 1959, 20 (03) :359-376
[64]   The correlation of bispectral index with endtidal sevoflurane concentration and haemodynamic parameters in preschoolers [J].
McCann, ME ;
Bacsik, J ;
Davidson, A ;
Auble, S ;
Sullivan, L ;
Laussen, P .
PAEDIATRIC ANAESTHESIA, 2002, 12 (06) :519-525
[65]   Validation of the bispectral index monitor during conscious and deep sedation in children [J].
McDermott, NB ;
VanSickle, T ;
Motas, D ;
Friesen, RH .
ANESTHESIA AND ANALGESIA, 2003, 97 (01) :39-43
[66]   Memory for unconsciously perceived events: Evidence from anesthetized patients [J].
Merikle, PM ;
Daneman, M .
CONSCIOUSNESS AND COGNITION, 1996, 5 (04) :525-541
[67]  
Mi W. D., 1999, European Journal of Anaesthesiology, V16, P47, DOI 10.1046/j.1365-2346.1999.00421.x
[68]   Does bispectral analysis of the electroencephalogram add anything but complexity? [J].
Miller, A ;
Sleigh, JW ;
Barnard, J ;
Steyn-Ross, DA .
BRITISH JOURNAL OF ANAESTHESIA, 2004, 92 (01) :8-13
[69]   Depth of consciousness and deep sedation attained in children as administered by nonanaesthesiologists in a children's hospital [J].
Motas, D ;
Mcdermott, NB ;
Vansickle, T ;
Friesen, RH .
PEDIATRIC ANESTHESIA, 2004, 14 (03) :256-260
[70]   Bispectral index in pediatrics: fashion or a new tool? [J].
Murat, I ;
Constant, I .
PEDIATRIC ANESTHESIA, 2005, 15 (03) :177-180