Biological fixation of comminuted subtrochanteric fractures with proximal femur locking compression plate

被引:38
作者
Saini, Pramod [1 ]
Kumar, Rakesh [1 ]
Shekhawat, Vishal [2 ]
Joshi, Narendra [2 ]
Bansal, Mahesh [2 ]
Kumar, Senthil [1 ]
机构
[1] All India Inst Med Sci, Dept Orthopaed, New Delhi 110029, India
[2] Sawai Man Singh Med Coll & Hosp, Dept Orthopaed, Jaipur 302004, Rajasthan, India
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2013年 / 44卷 / 02期
关键词
Proximal femur-locking compression plate; Subtrochanteric fractures; Biological fixation; ANGLED BLADE PLATE; DYNAMIC CONDYLAR SCREW; FEMORAL NAIL PFN; LONG-GAMMA-NAIL; INTRAMEDULLARY FIXATION; INDIRECT REDUCTION; INTERNAL-FIXATION; HIP SCREW; OSTEOSYNTHESIS; EXTRAMEDULLARY;
D O I
10.1016/j.injury.2012.10.037
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Subtrochanteric fractures are difficult fractures associated with high incidence of complications and various implants, both intramedullary and extramedullary, are available for their fixation. Traditional extramedullary implants are associated with higher rate of implant failure and varus collapse while the biomechanically better intramedullary nails are technically demanding and are associated with higher re-operation rates. This study was done to evaluate the outcome following biological (indirect) fixation of unstable comminuted subtrochanteric fractures with proximal femur-locking compression plate (PF-LCP). Methods: Thirty-five consecutive patients with comminuted subtrochanteric fractures were operated upon with PF-LCP by using an indirect reduction technique. Seinsheimer types 3-5 fractures were included in the study. Operating time, blood loss and any technical difficulty with the implant were recorded. Patients were followed clinically and radiologically for union at fracture site and implant-related complications. The Harris Hip Score was used to document hip function at final follow-up. Results: Thirty-two patients with average age of 44.7 years were available for final evaluation. The mean operating time was 79.5 min and total blood loss averaged 233.13 ml. Union was achieved in all cases with an average time of 15.62 weeks. Complications included two cases of delayed union and two cases of infection. Two cases had a shortening of 1 cm and one case had malunion with external rotation. No instances of implant failure or nonunion were recorded. Conclusion: Biological fixation of comminuted subtrochanteric fractures with PF-LCP provides stable fixation with high union rate and fewer complications. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:226 / 231
页数:6
相关论文
共 50 条
  • [41] Outcomes of locking plate fixation with fibular allograft augmentation for proximal humeral fractures in osteoporotic patients COMPARISON WITH LOCKING PLATE FIXATION ALONE
    Lee, S. H.
    Han, S. S.
    Yoo, B. M.
    Kim, J. W.
    BONE & JOINT JOURNAL, 2019, 101B (03) : 260 - 265
  • [42] Intuitive and Minimally Invasive Surgical Technique for Comminuted Mid-Shaft Clavicle Fractures: Fixation with an Anterior Mini Plate and Superior Locking Compression Plate
    Ok, Seungwoo
    Yoon, Seong-Meen
    Choi, Sungwook
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (03)
  • [43] Predictive Indicators for Complications of Proximal Humerus Fractures Treated with Locking Plate or Intramedullary Nail Fixation
    Wang, Hanzhou
    Liu, Yang
    Wang, Dong
    He, Yuanming
    Yao, Peifeng
    Lu, Tianchao
    Zhou, Junlin
    ORTHOPAEDIC SURGERY, 2022, 14 (09) : 2109 - 2118
  • [44] Functional Outcomes Following Locking Plate Fixation of Complex Proximal Humeral Fractures
    Ye, Tingjun
    Wang, Lei
    Zhuang, Chengyu
    Wang, Yazi
    Zhang, Weibin
    Qiu, Shijing
    ORTHOPEDICS, 2013, 36 (06) : E715 - E722
  • [45] Clinical Longer-Term Results After Internal Fixation of Proximal Humerus Fractures With a Locking Compression Plate (PHILOS)
    Hirschmann, Michael Tobias
    Fallegger, Basil
    Amsler, Felix
    Regazzoni, Pietro
    Gross, Thomas
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (05) : 286 - 293
  • [46] Analysis of early failure of the locking compression plate in osteoporotic proximal humerus fractures
    Micic, Ivan D.
    Kim, Kyung-Chun
    Shin, Dong-Ju
    Shin, Sang-Jin
    Kim, Poong-Taek
    Park, Il-Hyung
    Jeon, In-Ho
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2009, 14 (05) : 596 - 601
  • [47] A Biomechanical Analysis of Locking Plate Fixation With Minimally Invasive Plate Osteosynthesis in a Subtrochanteric Fracture Model
    Kim, Joon-Woo
    Oh, Chang-Wug
    Byun, Young-Soo
    Oh, Jong-Keon
    Kim, Hee-June
    Min, Woo-Kie
    Park, Sung-Ki
    Park, Byung-Chul
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 70 (01): : E19 - E23
  • [48] Titanium elastic nailing versus locking compression plating in school-aged pediatric subtrochanteric femur fractures
    Xu, Yunlan
    Bian, Jingxia
    Shen, Kaiying
    Xue, Bin
    MEDICINE, 2018, 97 (29)
  • [49] Helical plate fixation for treatment of comminuted fractures of the proximal and middle one-third of the humerus
    Yang, KH
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2005, 36 (01): : 75 - 80
  • [50] Displaced medial clavicle fractures: operative treatment with locking compression plate fixation
    Herman Frima
    Roderick M. Houwert
    Christoph Sommer
    European Journal of Trauma and Emergency Surgery, 2020, 46 : 207 - 213