Validity of Guatemalan Mother's Self-Reported Breast-Feeding Practices of 3-Month-Old Infants

被引:15
|
作者
Mazariegos, Monica [1 ]
Slater, Christine [2 ]
Ramirez-Zea, Manuel [1 ]
机构
[1] Inst Nutr Cent America & Panama INCAP, IINCAPs Res Ctr Prevent Chron Dis, Guatemala City, Guatemala
[2] IAEA, Div Human Hlth, Vienna, Austria
基金
美国国家卫生研究院;
关键词
Guatemala; infant and young children feeding; nutrition policy; breast-feeding; DEUTERIUM-OXIDE; MILK INTAKE; MATERNAL RECALL; DURATION; ENERGY; BIRTH;
D O I
10.1177/0379572116654644
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Introduction: Breast-feeding practices (BFPs) can be assessed by interviewing the mother about current feeding practices and with a 24-hour recall. It is crucial to establish the accuracy of these methods, which are commonly used by public health decision makers to design health policies aimed at increasing exclusive breast-feeding rates. Objective: We aimed to validate 2 self-report BFP instruments using the dose-to-mother deuterium oxide turnover technique (DMDOT) as the reference method. Methods: Breast-feeding practices were assessed by interviewing the mother about current feeding practices and with a 24-hour recall in 36 Guatemalan mother-infant pairs. The validity of these instruments was assessed using DMDOT as the reference method. Results: Both self-report instruments overestimated exclusively breast-fed (EBF) infants. Infants classified as EBF were 50% by the reported current feeding practice, 61% by the 24-hour recall, and only 36% using DMDOT. Sensitivity to detect EBF infants from the mother's self-report was 92% (95% CI: 62%-99%) while from the 24-hour recall was 100% (95% CI: 72%-100%, P < .01). However, specificity for both instruments was low, at 74% (95% CI: 51%-89%) for reported current feeding practice and at 61% (95% CI: 39%-79%) for the 24-hour recall (P < .01). Conclusion: Both reported current feeding practice and the 24-hour recall instruments overestimated exclusive breast-feeding. Nevertheless, the use of reported current feeding practice provided more accurate data to assess BFPs in a public health setting. Furthermore, population-based surveys should consider the overestimation of exclusive breast-feeding caused when using these BFP instruments.
引用
收藏
页码:494 / 503
页数:10
相关论文
共 1 条
  • [1] Evaluation of the Traditional Practices of Breastfeeding, Complementary Feeding and Increasing Breast Milk in Mothers with 0-24 Month-Old Infants: A Cross-Sectional Study
    Kaner, Gulsah
    Calik, Gamze
    Yurtdas, Gamze
    Baltali, Oya Halicioglu
    REVISTA ESPANOLA DE NUTRICION HUMANA Y DIETETICA, 2022, 26