A versatile gas-flow proportional counter for Mossbauer spectroscopy

被引:8
|
作者
Bibicu, I. [1 ]
Nicolescu, G. [2 ]
Cretu, C. [3 ]
机构
[1] Natl Inst Mat Phys, Bucharest 077125, Romania
[2] IFIN HH, Natl Inst Phys & Nucl Engn, Bucharest 077125, Romania
[3] Transylvania Univ, Dept Phys, Brasov 500036, Romania
来源
HYPERFINE INTERACTIONS | 2009年 / 192卷 / 1-3期
关键词
Detector; Conversion electron spectroscopy; Conversion X-ray spectroscopy; Fe-57; Sn-119; Eu-151; CONVERSION X-RAY; DETECTOR; CRITERIA;
D O I
10.1007/s10751-009-9950-7
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
This article presents a versatile gas-flow proportional counter for surface and transmission Mossbauer spectroscopy, suitable for studies with Fe-57, Sn-119 and Eu-151 isotopes. The main advantages obtained by new design are: (1) the height of the detection volume can be changed in large limits from 0 to 38 mm, (2) the detection volume can be choose symmetrical or not in respect with anode plan, (3) the anode replacement is easily (4) and different anode configuration can be used. The characteristics of the detector, operating at room temperature, are reported.
引用
收藏
页码:85 / 91
页数:7
相关论文
共 50 条
  • [1] A versatile gas-flow proportional counter for Mossbauer spectroscopy
    Bibicu, I.
    Nicolescu, G.
    Cretu, C.
    ISIAME 2008, 2009, : 587 - +
  • [2] A versatile gas-flow proportional counter for Mössbauer spectroscopy
    I. Bibicu
    G. Nicolescu
    C. Cretu
    Hyperfine Interactions, 2009, 192 : 85 - 91
  • [3] GAS-FLOW PROPORTIONAL COUNTER FOR LOW-TEMPERATURE CONVERSION ELECTRON MOSSBAUER-SPECTROSCOPY
    COOK, DC
    AGYEKUM, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1985, 12 (04): : 515 - 520
  • [4] A SIMPLE GAS-FLOW PROPORTIONAL COUNTER
    MALCOLME.DJ
    URCH, DS
    RADIOCHIMICA ACTA, 1970, 13 (02) : 114 - &
  • [5] OPTIMIZATION OF A CONVERSION ELECTRON MOSSBAUER-SPECTROSCOPY GAS-FLOW HE/CH4 PROPORTIONAL COUNTER
    HANZEL, D
    GRIESBACH, P
    MEISEL, W
    GUTLICH, P
    HYPERFINE INTERACTIONS, 1992, 71 (1-4): : 1441 - 1444
  • [6] NEW DESIGN FOR A GAS-FLOW PROPORTIONAL COUNTER
    BEHNRIGG.F
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1963, 34 (04): : 392 - &
  • [7] WORKING CHARACTERISTICS OF GAS-FLOW PROPORTIONAL COUNTER DESIGNED FOR X-RAY MOSSBAUER SPECTROMETRY
    NOMURA, K
    UJIHIRA, Y
    BUNSEKI KAGAKU, 1985, 34 (01) : T5 - T11
  • [8] A SPURIOUS PULSE PROBLEM IN A GAS-FLOW PROPORTIONAL COUNTER
    GRADY, DJ
    ROBERTSON, JC
    NUCLEAR INSTRUMENTS & METHODS, 1981, 179 (02): : 317 - 319
  • [9] GAS-FLOW PROPORTIONAL COUNTER FOR NA KALPHAX RADIATION
    MCHARDY, WJ
    BIRNIE, AC
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1974, 7 (04): : 318 - 318
  • [10] DETERMINATION OF THE COUNTING EFFICIENCY OF A GAS-FLOW PROPORTIONAL COUNTER
    KAHN, B
    PHYSICAL REVIEW, 1952, 87 (01): : 175 - 175