摘要
In this paper, we present two new numerical observers (NO) based on machine learning for image quality assessment. The proposed NOs aim to predict human observer performance in a cardiac perfusion-defect detection task for single-photon emission computed tomography (SPECT) images. Human observer (HumO) studies are now considered to be the gold standard for task-based evaluation of medical images. However such studies are impractical for use in early stages of development for imaging devices and algorithms, because they require extensive involvement of trained human observers who must evaluate a large number of images. To address this problem, numerical observers (also called model observers) have been developed as a surrogate for human observers. The channelized Hotelling observer (CHO), with or without internal noise model, is currently the most widely used NO of this kind. In our previous work we argued that development of a NO model to predict human observers' performance can be viewed as a machine learning (or system identification) problem. This consideration led us to develop a channelized support vector machine (CSVM) observer, a kernel-based regression model that greatly outperformed the popular and widely used CHO. This was especially evident when the numerical observers were evaluated in terms of generalization performance. To evaluate generalization we used a typical situation for the practical use of a numerical observer: after optimizing the NO (which for a CHO might consist of adjusting the internal noise model) based upon a broad set of reconstructed images, we tested it on a broad (but different) set of images obtained by a different reconstruction method. In this manuscript we aim to evaluate two new regression models that achieve accuracy higher than the CHO and comparable to our earlier CSVM method, while dramatically reducing model complexity and computation time. The new models are defined in a Bayesian machine-learning framework: a channelized relevance vector machine (CRVM) and a multi-kernel CRVM (MKCRVM).
引用
收藏
页码:1609 / 1618
页数:10
相关论文
共 50 条
  • [1] Learning a Channelized Observer for Image Quality Assessment
    Brankov, Jovan G.
    Yang, Yongyi
    Wei, Liyang
    El Naqa, Issam
    Wernick, Miles N.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (07) : 991 - 999
  • [2] On Efficient Assessment of Image-Quality Metrics Based on Linear Model Observers
    Wunderlich, Adam
    Noo, Frederic
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (03) : 568 - 578
  • [3] MACHINE LEARNING, COMPRESSION, AND IMAGE QUALITY
    Israel, Steven A.
    Irvine, John M.
    Tate, Steven
    2020 IEEE APPLIED IMAGERY PATTERN RECOGNITION WORKSHOP (AIPR): TRUSTED COMPUTING, PRIVACY, AND SECURING MULTIMEDIA, 2020,
  • [4] NMF-Based Image Quality Assessment Using Extreme Learning Machine
    Wang, Shuigen
    Deng, Chenwei
    Lin, Weisi
    Huang, Guang-Bin
    Zhao, Baojun
    IEEE TRANSACTIONS ON CYBERNETICS, 2017, 47 (01) : 232 - 243
  • [5] Machine Learning and Deep Learning Methods for Fast and Accurate Assessment of Transthoracic Echocardiogram Image Quality
    Nazar, Wojciech
    Nazar, Krzysztof
    Danilowicz-Szymanowicz, Ludmila
    LIFE-BASEL, 2024, 14 (06):
  • [6] A color image quality assessment using a reduced-reference image machine learning expert
    Charrier, Christophe
    Lebrun, Gilles
    Lezoray, Olivier
    IMAGE QUALITY AND SYSTEM PERFORMANCE V, 2008, 6808
  • [7] Wound image evaluation with machine learning
    Veredas, Francisco J.
    Luque-Baena, Rafael M.
    Martin-Santos, Francisco J.
    Morilla-Herrera, Juan C.
    Morente, Laura
    NEUROCOMPUTING, 2015, 164 : 112 - 122
  • [8] Practical issues and methodology in assessment of image quality using model observers
    Abbey, CK
    Barrett, HH
    Eckstein, MP
    PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 182 - 194
  • [9] An Exploration of NIIRS, Image Quality, and Machine Learning
    Irvine, John M.
    Israel, Steven A.
    GEOSPATIAL INFORMATICS X, 2020, 11398
  • [10] MAFIA-CT: MAchine Learning Tool for Image Quality Assessment in Computed Tomography
    Lima, Thiago V. M.
    Melchior, Silvan
    Oezden, Ismail
    Nitzsche, Egbert
    Binder, Joerg
    Lutters, Gerd
    MEDICAL IMAGE UNDERSTANDING AND ANALYSIS (MIUA 2021), 2021, 12722 : 472 - 487