Feature extraction; Monitoring; Indexes; Quality assessment; Detectors; Noise measurement; False alarm reduction; Internet-of-Things (IoT) medical devices and smartphone health monitoring; motion artifact detector; photoplethysmography (PPG); PPG signal quality assessment (SQA); MOTION ARTIFACT; PHOTOPLETHYSMOGRAPHIC SIGNALS; REDUCTION; ALGORITHM; INDEXES;
D O I
10.1109/TIM.2020.2971132
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this article, we propose a new on-device photoplethysmography (PPG) signal quality assessment (SQA) system based on the first-order (FO) predictor coefficient (PC) of differenced sensor (DS) signal that is capable of significantly reducing false alarms and timely notifying sensor disconnection and saturation in unsupervised health monitoring. The proposed system consists of the DS signal computation, random noise addition, PC estimation, and hierarchical decision rules. The proposed system is evaluated by using varieties of sensor signals taken from standard databases and the PPG signals recorded using three PPG sensing modules available at our Biomedical System Laboratory. Results show that the proposed method achieves correct detection rates of 98.22%, 80.09%, and 99.79% for noise-free PPG segments, motion artifacts corrupted segments, and pulse-free segments, respectively, and also outperforms other SQA methods. The proposed method had a false alarm reduction rate of 90.71% and a missed acceptable quality rate of 1.78%. Real-time implementation on the Arduino Due computing platform with a 32-bit Cortex-M3 processor, 512-kB flash memory, and 96-kB data memory demonstrates that the proposed on-device SQA system consumes 0.141 mJ with an overall accuracy of 93.21%, whereas the kurtosis and Shannon entropy (KSE) and the fiducial and template (FT)-based methods consume 109.08 and 6.71 mJ with overall accuracies of 39.24% and 74.13%, respectively. The proposed system has great potential for developing energy-efficient accurate and reliable Internet of Things (IoT) and smartphone-based health monitoring systems.
引用
收藏
页码:6351 / 6361
页数:11
相关论文
共 8 条
  • [1] Evaluation of Objective Distortion Measures for Automatic Quality Assessment of Processed PPG Signals for Real-Time Health Monitoring Devices
    Reddy, Gangireddy Narendra Kumar
    Manikandan, M. Sabarimalai
    Murty, N. V. L. Narasimha
    IEEE ACCESS, 2022, 10 : 15707 - 15745
  • [2] Integrated intelligent system for water quality monitoring and theft detection
    Karthikeyan, V
    Visu, Y. Palin
    Raja, E.
    WATER PRACTICE AND TECHNOLOGY, 2023, 18 (12) : 3035 - 3047
  • [3] Lightweight Photoplethysmography Quality Assessment for Real-time IoT-based Health Monitoring using Unsupervised Anomaly Detection
    Mahmoudzadeh, Aysan
    Azimi, Iman
    Rahmani, Amir M.
    Liljeberg, Pasi
    12TH INTERNATIONAL CONFERENCE ON AMBIENT SYSTEMS, NETWORKS AND TECHNOLOGIES (ANT) / THE 4TH INTERNATIONAL CONFERENCE ON EMERGING DATA AND INDUSTRY 4.0 (EDI40) / AFFILIATED WORKSHOPS, 2021, 184 : 140 - 147
  • [4] Real-Time Signal Quality-Aware ECG Telemetry System for IoT-Based Health Care Monitoring
    Satija, Udit
    Ramkumar, Barathram
    Manikandan, M. Sabarimalai
    IEEE INTERNET OF THINGS JOURNAL, 2017, 4 (03): : 815 - 823
  • [5] IoT-based real-time monitoring system for fall detection of the elderly with passive RFID sensor tags
    Takatou, Koichi
    Shinomiya, Norihiko
    35TH INTERNATIONAL TECHNICAL CONFERENCE ON CIRCUITS/SYSTEMS, COMPUTERS AND COMMUNICATIONS (ITC-CSCC 2020), 2020, : 193 - 196
  • [6] An Intelligent LoRaWAN-Based IoT Device for Monitoring and Control Solutions in Smart Farming Through Anomaly Detection Integrated With Unsupervised Machine Learning
    Alumfareh, Maram Fahaad
    Humayun, Mamoona
    Ahmad, Zulfiqar
    Khan, Asfandyar
    IEEE ACCESS, 2024, 12 : 119072 - 119086
  • [7] A Lightweight and Affordable Sleep Quality Monitoring and Visualization System with a GSR Sensor for Users in Rural Areas to Facilitate Tele-Health
    Du, Yang
    Sun, Qiming
    Wang, Kou
    Tang, Tiffany Y.
    DIGITAL HUMAN MODELING AND APPLICATIONS IN HEALTH, SAFETY, ERGONOMICS AND RISK MANAGEMENT. HEALTHCARE APPLICATIONS, DHM 2019, PT II, 2019, 11582 : 41 - 49
  • [8] Utilizing an Arduino Uno-Based System with Integrated Sensor Data Fusion and Filtration Techniques for Enhanced Air Quality Monitoring in Residential Spaces
    Rudavskyi, Ivan
    Klym, Halyna
    Kostiv, Yuriy
    Karbovnyk, Ivan
    Zhydenko, Illia
    Popov, Anatoli I.
    Konuhova, Marina
    APPLIED SCIENCES-BASEL, 2024, 14 (19):