Dynamic Cardiac PET Imaging: Extraction of Time-Activity Curves Using ICA and a Generalized Gaussian Distribution Model

被引:16
|
作者
Mabrouk, Rostom [1 ]
Dubeau, Francois [2 ]
Bentabet, Layachi [3 ]
机构
[1] Univ Sherbrooke, Dept Comp Sci, Sherbrooke, PQ 8217000, Canada
[2] Univ Sherbrooke, Dept Math, Sherbrooke, PQ 8217000, Canada
[3] Bishops Univ, Dept Comp Sci, Sherbrooke, PQ J1M 1Z7, Canada
关键词
Independent component analysis (ICA); input function (IF); kinetic modeling; positron emission tomography (PET); POSITRON-EMISSION-TOMOGRAPHY; INDEPENDENT COMPONENT ANALYSIS; INPUT FUNCTION; FDG-PET; IMAGES; QUANTIFICATION; RADIOACTIVITY; DISPERSION;
D O I
10.1109/TBME.2012.2221463
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Kinetic modeling of metabolic and physiologic cardiac processes in small animals requires an input function (IF) and a tissue time-activity curves (TACs). In this paper, we present a mathematical method based on independent component analysis (ICA) to extract the IF and the myocardium's TACs directly from dynamic positron emission tomography (PET) images. The method assumes a super-Gaussian distribution model for the blood activity, and a sub-Gaussian distribution model for the tissue activity. Our appreach was applied on 22 PET measurement sets of small animals, which were obtained from the three most frequently used cardiac radiotracers, namely: desoxy-fluoro-glucose (F-18-FDG), [N-13]-ammonia, and [C-11]-acetate. Our study was extended to PET human measurements obtained with the Rubidium-82 (Rb-82) radiotracer. The resolved mathematical IF values compare favorably to those derived from curves extracted from regions of interest (ROI), suggesting that the procedure presents a reliable alternative to serial blood sampling for small-animal cardiac PET studies.
引用
收藏
页码:63 / 71
页数:9
相关论文
共 8 条
  • [1] Enhanced Extraction of Blood and Tissue Time-Activity Curves in Cardiac Mouse FDG PET Imaging by Means of Constrained Nonnegative Matrix Factorization
    Sarrhini, Otman
    D'Orleans-Juste, Pedro
    Rousseau, Jacques A. A.
    Beaudoin, Jean-Francois
    Lecomte, Roger
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2023, 2023
  • [2] FACTOR-ANALYSIS FOR EXTRACTION OF BLOOD TIME-ACTIVITY CURVES IN DYNAMIC FDG-PET STUDIES
    WU, HM
    HOH, CK
    CHOI, Y
    SCHELBERT, HR
    HAWKINS, RA
    PHELPS, ME
    HUANG, SC
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (09) : 1714 - 1722
  • [3] Derived Input Function from Dynamic Cardiac 18F-FDG PET Images in Rodents based on the Generalized Gaussian ICA Model
    Mabrouk, R.
    Prevost, S.
    Dubeau, F.
    Bentabet, L.
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 792 - 795
  • [4] Estimation of dynamic time activity curves from dynamic cardiac SPECT imaging
    Hossain, J.
    Du, Y.
    Links, J.
    Rahmim, A.
    Karakatsanis, N.
    Akhbardeh, A.
    Lyons, J.
    Frey, E. C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (08) : 3193 - U501
  • [5] Extraction of a plasma time-activity curve from dynamic brain PET images based on independent component analysis
    Naganawa, M
    Kimura, Y
    Ishii, K
    Oda, K
    Ishiwata, K
    Matani, A
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (02) : 201 - 210
  • [6] Characteristics of time-activity curves obtained from dynamic 11C-methionine PET in common primary brain tumors
    Nomura, Yuichi
    Asano, Yoshitaka
    Shinoda, Jun
    Yano, Hirohito
    Ikegame, Yuka
    Kawasaki, Tomohiro
    Nakayama, Noriyuki
    Maruyama, Takashi
    Muragaki, Yoshihiro
    Iwama, Toru
    JOURNAL OF NEURO-ONCOLOGY, 2018, 138 (03) : 649 - 658
  • [7] Automatic TAC extraction from dynamic cardiac PET imaging using iterative correlation from a population template
    Mateos-Perez, Jose M.
    Desco, Manuel
    Dae, Michael W.
    Garcia-Villalba, Carmen
    Cusso, Lorena
    Vaquero, Juan J.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2013, 111 (02) : 308 - 314
  • [8] High Temporal Resolution Total-Body Dynamic PET Imaging Based on Pixel-Leve Time-Activity Curve Correction
    Chen, Zixiang
    Wu, Yaping
    Zhang, Na
    Sun, Tao
    Shen, Yu
    Zheng, Hairong
    Liang, Dong
    Wang, Meiyun
    Hu, Zhanli
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (12) : 3689 - 3702