Parallel Validation of Three Molecular Devices for Simultaneous Detection and Identification of Influenza A and B and Respiratory Syncytial Viruses

被引:48
|
作者
Ling, Lifen [1 ,2 ]
Kaplan, Samuel E. [2 ]
Lopez, Juan C. [2 ]
Stiles, Jeffrey [2 ]
Lu, Xuedong [1 ]
Tang, Yi-Wei [2 ,3 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 8, Dept Lab Med, Shenzhen, Peoples R China
[2] Mem Sloan Kettering Canc Ctr, Dept Lab Med, 1275 York Ave, New York, NY 10021 USA
[3] Cornell Univ, Weill Med Coll, Dept Pathol & Lab Med, New York, NY 10021 USA
关键词
influenza viruses A and B; respiratory syncytial virus; molecular testing; hands-on time; turnaround time; PERFORMANCE EVALUATION; DIAGNOSTIC-ACCURACY; CLINICAL-EVALUATION; MULTIPLEX PCR; VIRAL PANEL; RSV ASSAY; FLU A/B; INFECTION; TIME; MANAGEMENT;
D O I
10.1128/JCM.01691-17
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Rapid identification of respiratory pathogens, such as influenza virus A (FluA), influenza virus B (FluB), and respiratory syncytial virus (RSV), reduces unnecessary antimicrobial use and enhances infection control practice. We performed a comparative evaluation of three molecular methods: (i) the Aries Flu A/B & RSV, (ii) the Xpert Xpress Flu/RSV, and (iii) the Cobas Flu A/B & RSV assays. The clinical performances of the three methods were evaluated using 200 remnant nasopharyngeal swab (NPS) specimens against a combined reference standard. The limits of detection (LODs) were determined using FluA, FluB, and RSV control strains with known titers. The 95% LODs were between 1.702 and 0.0003 50% tissue culture infective dose (TCID50), with no significant differences revealed among the three assays. Perfect qualitative detection agreement was obtained in the reproducibility study. The Cobas assay failed at the first run on 13 clinical specimens, resulting in an invalid rate of 6.5%. The sensitivities and specificities for all assays were 96.0 to 100.0% and 99.3 to 100% for all three viruses. For on-demand single-specimen and batched 12-specimen workflows, the test turnaround times were 115.5 and 128.8 min for the Aries assay (12 sample capacity), 34.2 and 44.2 min for the Xpress assay (16 sample capacity), and 21.0 and 254.4 min for the Cobas assay (one instrument), respectively. In summary, the Aries, Xpress, and Cobas Liat assays demonstrated excellent sensitivities and specificities for simultaneous detection and identification of FluA, FluB, and RSV from NPS specimens in cancer patients. Test turnaround time was significantly shorter on the Xpress when instrument scalability is unlimited.
引用
收藏
页数:6
相关论文
共 44 条
  • [21] Performance evaluation of EuDxTM ufPCR Flu & RSV detection kit for detection of influenza A/B and respiratory syncytial virus
    Lim, Yong Kwan
    Kweon, Oh Joo
    Kim, Hye Ryoun
    Kim, Tae-Hyoung
    Cho, Ah Ra
    Lee, Mi-Kyung
    JOURNAL OF MICROBIOLOGY IMMUNOLOGY AND INFECTION, 2021, 54 (03) : 518 - 521
  • [22] Comparison of Cepheid Xpert Flu/RSV XC and BioFire FilmArray for Detection of Influenza A, Influenza B, and Respiratory Syncytial Virus
    Wahrenbrock, Mark G.
    Matushek, Scott
    Boonlayangoor, Sue
    Tesic, Vera
    Beavis, Kathleen G.
    Charnot-Katsikas, Angella
    JOURNAL OF CLINICAL MICROBIOLOGY, 2016, 54 (07) : 1902 - 1903
  • [23] Molecular detection and characterization of respiratory syncytial virus B genotypes circulating in Pakistani children
    Bashir, Uzma
    Nisar, Nadia
    Mahmood, Nayab
    Alam, Muhammad Masroor
    Sadia, Hajra
    Zaidi, Syed Sohail Zahoor
    INFECTION GENETICS AND EVOLUTION, 2017, 47 : 125 - 131
  • [24] Facile, Rapid, and Low-Cost Detection for Influenza Viruses and Respiratory Syncytial Virus Based on a Catalytic DNA Assembly Circuit
    Wu, Huina
    Zou, Mingyuan
    Fan, Xiaobo
    Su, Feiya
    Xiao, Feng
    Zhou, Meiling
    Sun, Yan
    Zhao, Fengfeng
    Wu, Guoqiu
    ACS OMEGA, 2022, 7 (17): : 15074 - 15081
  • [25] Clinical impact of the rapid molecular detection of RSV and influenza A and B viruses in the emergency department
    Yin, Nicolas
    Van Nuffelen, Marc
    Bartiaux, Magali
    Preseau, Thierry
    Roggen, Inge
    Delaunoy, Sabrina
    Mahadeb, Bhavna
    Dahma, Hafid
    Busson, Laurent
    Vandenberg, Olivier
    Hallin, Marie
    PLOS ONE, 2022, 17 (09):
  • [26] Prospective and retrospective evaluation of the Cepheid Xpert® Flu/RSV XC assay for rapid detection of influenza A, influenza B, and respiratory syncytial virus
    Salez, Nicolas
    Nougairede, Antoine
    Ninove, Laetitia
    Zandotti, Christine
    de Lamballerie, Xavier
    Charrel, Remi N.
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2015, 81 (04) : 256 - 258
  • [27] Comparison of the BD Directigen Flu A+B Kit and the Abbott TestPack RSV with a multiplex RT-PCR ELISA for rapid detection of influenza viruses and respiratory syncytial virus
    Gröndahl, B
    Puppe, W
    Weigl, J
    Schmitt, HJ
    CLINICAL MICROBIOLOGY AND INFECTION, 2005, 11 (10) : 848 - 850
  • [28] Application of three duplex real-time PCR assays for simultaneous detection of human seasonal and avian influenza viruses
    Stefanska, Ilona
    Dzieciatkowski, Tomasz
    Brydak, Lidia B.
    Romanowska, Magdalena
    ARCHIVES OF VIROLOGY, 2013, 158 (08) : 1743 - 1753
  • [29] Accurate PCR Detection of Influenza A/B and Respiratory Syncytial Viruses by Use of Cepheid Xpert Flu plus RSV Xpress Assay in Point-of-Care Settings: Comparison to Prodesse ProFlu
    Cohen, Daniel M.
    Kline, Jennifer
    May, Larissa S.
    Harnett, Glenn Eric
    Gibson, Jane
    Liang, Stephen Y.
    Rafique, Zubaid
    Rodriguez, Carina A.
    McGann, Kevin M.
    Gaydos, Charlotte A.
    Mayne, Donna
    Phillips, David
    Cohenl, Jason
    JOURNAL OF CLINICAL MICROBIOLOGY, 2018, 56 (02)
  • [30] Comparison of two commercial molecular assays for simultaneous detection of respiratory viruses in clinical samples using two automatic electrophoresis detection systems
    van Coppenraet, L. E. S. Bruijnesteijn
    Swanink, C. M. A.
    van Zwet, A. A.
    Nijhuis, R. H. T.
    Schirm, J.
    Wallinga, J. A.
    Ruijs, G. J. H. M.
    JOURNAL OF VIROLOGICAL METHODS, 2010, 169 (01) : 188 - 192