Three-dimensional assessment of lower limb alignment: Accuracy and reliability

被引:40
|
作者
Fuermetz, J. [1 ]
Sass, J. [1 ]
Ferreira, T. [2 ,3 ]
Jalali, J. [2 ]
Kovacs, L. [2 ]
Mueck, F. [4 ]
Degen, N. [1 ]
Thaller, P. H. [1 ]
机构
[1] Univ Hosp Munich LMU, Dept Gen Trauma & Reconstruct Surg, 3D Surg, Munich, Germany
[2] Tech Univ Munich, Univ Hosp Klinikum Rechts Isar, Dept Plast Surg & Hand Surg, Res Grp CAPS Comp Aided Plast Surg, Munich, Germany
[3] Univ Lisbon, Fac Sci, Lisbon, Portugal
[4] Univ Hosp Munich LMU, Dept Radiol, Munich, Germany
关键词
3D anatomy; 3D bone modeling; Alignment; Computed tomography; Patient-specific implant; Pre-operative planning; TOTAL KNEE ARTHROPLASTY; GUIDES; OSTEOTOMIES; DEFORMITIES;
D O I
10.1016/j.knee.2018.10.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Three-dimensional (3D) surgical planning and patient-specific implants are becoming increasingly popular in orthopedics and trauma surgery. In contrast to the established and standardized alignment assessment on two-dimensional (2D) long standing radiographs (LSRs) there is neither a standardized nor a validated protocol for the analysis of 3D bone models of the lower limb. This study aimed to create a prerequisite for pre-operative planning. Methods: According to 2D analysis and after meticulous research, 24 landmarks were defined on 3D bone models obtained from computed axial tomography (CT) scans for a 3D alignment assessment. Three observers with different experience levels performed the test three different times on three specimens. Intraobserver and interobserver variability of the landmarks and the intraclass correlation coefficient (ICC) of the resulting axes and joint angles were evaluated. Results: Overall, the intraobserver and interobserver variability was low, with a mean deviation <5 mm for all landmarks. The ICC of all joint angles and axis deviations was >0.8, except for tibial torsion (ICC = 0.69). All knee joint angles showed excellent ICC (>0.95). Conclusions: Using the defined landmarks, a standardized 3D alignment assessment with low intraobserver and interobserver variability and high ICC values for the knee joint angles can be performed regardless of examiner's experience. The described method serves as a reliable standardized protocol for a 3D malalignment test of the lower limb. Three-dimensional pre-operative analysis might enhance understanding of deformities and lead to a new focus in surgical planning. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:185 / 193
页数:9
相关论文
共 50 条
  • [41] Accuracy of three-dimensional soft tissue simulation in bimaxillary osteotomies
    Liebregts, Jeroen
    Xi, Tong
    Timmermans, Maarten
    de Koning, Martien
    Berge, Stefaan
    Hoppenreijs, Theo
    Maal, Thomas
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2015, 43 (03) : 329 - 335
  • [42] Interobserver and Intraobserver Reliability of Computed Tomography-Based Three-Dimensional Preoperative Planning for Primary Total Knee Arthroplasty
    Miura, Michiaki
    Hagiwara, Shigeo
    Nakamura, Junichi
    Wako, Yasushi
    Kawarai, Yuya
    Ohtori, Seiji
    JOURNAL OF ARTHROPLASTY, 2018, 33 (05) : 1572 - 1578
  • [43] How accurate are orthopaedic surgeons in visually estimating lower limb alignment ?
    Shetty, Gautam M.
    Mullaji, Arun
    Lingaraju, A. Parameshwarappa
    Bhayde, Sagar
    ACTA ORTHOPAEDICA BELGICA, 2011, 77 (05): : 638 - 643
  • [44] Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method
    You, Sung-Hye
    Suh, Sang-il
    Ryoo, In-Seon
    Son, Gyu-Ri
    Lee, Young-Hen
    Seo, Hyung Suk
    Lee, Nam Joon
    Seol, Hae Young
    ULTRASONOGRAPHY, 2017, 36 (01) : 17 - 24
  • [45] Three-dimensional computed tomographic angiography in lower extremity revascularization
    Ishikawa, M
    Morimoto, N
    Sasajima, T
    Kubo, Y
    SURGERY TODAY, 1999, 29 (03) : 243 - 247
  • [46] Three-dimensional computed tomographic angiography in lower extremity revascularization
    Ishikawa M.
    Morimoto N.
    Sasajima T.
    Kubo Y.
    Surgery Today, 1999, 29 (3) : 243 - 247
  • [47] Three-dimensional analysis of accuracy of component positioning in total knee arthroplasty with patient specific and conventional instruments: A randomized controlled trial
    De Vloo, Raf
    Pellikaan, Pim
    Dhollander, Aad
    Vander Sloten, Jos
    KNEE, 2017, 24 (06) : 1469 - 1477
  • [48] Two-dimensional measurement misidentifies alignment outliers in total knee arthroplasty: a comparison of two- and three-dimensional measurements
    Hideki Ueyama
    Yukihide Minoda
    Ryo Sugama
    Yoichi Ohta
    Kazumasa Yamamura
    Suguru Nakamura
    Susumu Takemura
    Hiroaki Nakamura
    Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 1497 - 1503
  • [49] Planning Accuracy and Stem Offset Assessment in Digital Two-Dimensional Versus Three-Dimensional Planning in Cementless Hip Arthroplasty: A Systematic Review and Meta-Analysis
    Parisi, Francesco Rosario
    Zampogna, Biagio
    Zampoli, Andrea
    Ferrini, Augusto
    Albimonti, Giorgio
    Del Monaco, Alessandro
    Za, Pierangelo
    Papalia, Giuseppe Francesco
    Papalia, Rocco
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (21)
  • [50] Two-dimensional measurement misidentifies alignment outliers in total knee arthroplasty: a comparison of two- and three-dimensional measurements
    Ueyama, Hideki
    Minoda, Yukihide
    Sugama, Ryo
    Ohta, Yoichi
    Yamamura, Kazumasa
    Nakamura, Suguru
    Takemura, Susumu
    Nakamura, Hiroaki
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (05) : 1497 - 1503