Three-dimensional assessment of lower limb alignment: Accuracy and reliability

被引:40
|
作者
Fuermetz, J. [1 ]
Sass, J. [1 ]
Ferreira, T. [2 ,3 ]
Jalali, J. [2 ]
Kovacs, L. [2 ]
Mueck, F. [4 ]
Degen, N. [1 ]
Thaller, P. H. [1 ]
机构
[1] Univ Hosp Munich LMU, Dept Gen Trauma & Reconstruct Surg, 3D Surg, Munich, Germany
[2] Tech Univ Munich, Univ Hosp Klinikum Rechts Isar, Dept Plast Surg & Hand Surg, Res Grp CAPS Comp Aided Plast Surg, Munich, Germany
[3] Univ Lisbon, Fac Sci, Lisbon, Portugal
[4] Univ Hosp Munich LMU, Dept Radiol, Munich, Germany
关键词
3D anatomy; 3D bone modeling; Alignment; Computed tomography; Patient-specific implant; Pre-operative planning; TOTAL KNEE ARTHROPLASTY; GUIDES; OSTEOTOMIES; DEFORMITIES;
D O I
10.1016/j.knee.2018.10.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Three-dimensional (3D) surgical planning and patient-specific implants are becoming increasingly popular in orthopedics and trauma surgery. In contrast to the established and standardized alignment assessment on two-dimensional (2D) long standing radiographs (LSRs) there is neither a standardized nor a validated protocol for the analysis of 3D bone models of the lower limb. This study aimed to create a prerequisite for pre-operative planning. Methods: According to 2D analysis and after meticulous research, 24 landmarks were defined on 3D bone models obtained from computed axial tomography (CT) scans for a 3D alignment assessment. Three observers with different experience levels performed the test three different times on three specimens. Intraobserver and interobserver variability of the landmarks and the intraclass correlation coefficient (ICC) of the resulting axes and joint angles were evaluated. Results: Overall, the intraobserver and interobserver variability was low, with a mean deviation <5 mm for all landmarks. The ICC of all joint angles and axis deviations was >0.8, except for tibial torsion (ICC = 0.69). All knee joint angles showed excellent ICC (>0.95). Conclusions: Using the defined landmarks, a standardized 3D alignment assessment with low intraobserver and interobserver variability and high ICC values for the knee joint angles can be performed regardless of examiner's experience. The described method serves as a reliable standardized protocol for a 3D malalignment test of the lower limb. Three-dimensional pre-operative analysis might enhance understanding of deformities and lead to a new focus in surgical planning. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:185 / 193
页数:9
相关论文
共 50 条
  • [21] Influence of lower limb rotation on hindfoot alignment using a conventional two-dimensional radiographic technique
    Baverel, L.
    Brilhault, J.
    Odri, G.
    Boissard, M.
    Lintz, Francois
    FOOT AND ANKLE SURGERY, 2017, 23 (01) : 44 - 49
  • [22] Three-dimensional limb lengthening after total knee arthroplasty in a simulation study
    Ohmori, Takaaki
    Kabata, Tamon
    Kajino, Yoshitomo
    Inoue, Daisuke
    Taga, Tadashi
    Yamamoto, Takashi
    Takagi, Tomoharu
    Yoshitani, Junya
    Ueno, Takuro
    Ueoka, Ken
    Tsuchiya, Hiroyuki
    MODERN RHEUMATOLOGY, 2018, 28 (06) : 1029 - 1034
  • [23] Influence of axial limb rotation on radiographic lower limb alignment: a systematic review
    Ahrend, Marc-Daniel
    Baumgartner, Heiko
    Ihle, Christoph
    Histing, Tina
    Schroeter, Steffen
    Finger, Felix
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (11) : 3349 - 3366
  • [24] Accuracy of Three-Dimensional Soft Tissue Prediction in Orthognathic Cases Using Dolphin Three-Dimensional Software
    Elshebiny, Tarek
    Morcos, Sherif
    Mohammad, Abdulaziz
    Quereshy, Faisal
    Valiathan, Manish
    JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (02) : 525 - 528
  • [25] Wafer-to-Wafer Alignment for Three-Dimensional Integration: A Review
    Lee, Sang Hwui
    Chen, Kuan-Neng
    Lu, James Jian-Qiang
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2011, 20 (04) : 885 - 898
  • [26] Reliability of the assessment of lower limb torsion using computed tomography: analysis of five different techniques
    Liodakis, Emmanouil
    Doxastaki, Iosifina
    Chu, Kongfai
    Krettek, Christian
    Gaulke, Ralph
    Citak, Musa
    Kenawey, Mohamed
    SKELETAL RADIOLOGY, 2012, 41 (03) : 305 - 311
  • [27] Effects of Geometry on the Mechanics and Alignment of Three-Dimensional Engineered Microtissues
    Bose, Prasenjit
    Eyckmans, Jeroen
    Nguyen, Thao D.
    Chen, Christopher S.
    Reich, Daniel H.
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2019, 5 (08): : 3843 - 3855
  • [28] Can accuracy with the iASSIST navigation be confirmed by assessment? A multi-center prospective randomized controlled trial with independent three-dimensional image assessment
    Tsuda, Kosuke
    Shibuya, Takaaki
    Okamoto, Nobukazu
    Shiigi, Eiichi
    Shirakawa, Nobuyuki
    Hosaka, Kunihiro
    Akagi, Ryuichiro
    Ohdera, Toshihiro
    KNEE, 2021, 30 : 344 - 352
  • [29] Development of a Three-Dimensional Hand Model Using Three-Dimensional Stereophotogrammetry: Assessment of Image Reproducibility
    Hoevenaren, Inge A.
    Meulstee, J.
    Krikken, E.
    Berge, S. J.
    Ulrich, D. J. O.
    Maal, Thomas J. J.
    PLOS ONE, 2015, 10 (09):
  • [30] Accuracy and Reliability of Length Measurements on Three-Dimensional Computed Tomography Using Open-Source OsiriX Software
    Gihyeon Kim
    Ho-Joong Jung
    Han-Jun Lee
    Jae-Sung Lee
    Seungbum Koo
    Seung-Hwan Chang
    Journal of Digital Imaging, 2012, 25 : 486 - 491