Three-dimensional assessment of lower limb alignment: Accuracy and reliability

被引:40
|
作者
Fuermetz, J. [1 ]
Sass, J. [1 ]
Ferreira, T. [2 ,3 ]
Jalali, J. [2 ]
Kovacs, L. [2 ]
Mueck, F. [4 ]
Degen, N. [1 ]
Thaller, P. H. [1 ]
机构
[1] Univ Hosp Munich LMU, Dept Gen Trauma & Reconstruct Surg, 3D Surg, Munich, Germany
[2] Tech Univ Munich, Univ Hosp Klinikum Rechts Isar, Dept Plast Surg & Hand Surg, Res Grp CAPS Comp Aided Plast Surg, Munich, Germany
[3] Univ Lisbon, Fac Sci, Lisbon, Portugal
[4] Univ Hosp Munich LMU, Dept Radiol, Munich, Germany
关键词
3D anatomy; 3D bone modeling; Alignment; Computed tomography; Patient-specific implant; Pre-operative planning; TOTAL KNEE ARTHROPLASTY; GUIDES; OSTEOTOMIES; DEFORMITIES;
D O I
10.1016/j.knee.2018.10.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Three-dimensional (3D) surgical planning and patient-specific implants are becoming increasingly popular in orthopedics and trauma surgery. In contrast to the established and standardized alignment assessment on two-dimensional (2D) long standing radiographs (LSRs) there is neither a standardized nor a validated protocol for the analysis of 3D bone models of the lower limb. This study aimed to create a prerequisite for pre-operative planning. Methods: According to 2D analysis and after meticulous research, 24 landmarks were defined on 3D bone models obtained from computed axial tomography (CT) scans for a 3D alignment assessment. Three observers with different experience levels performed the test three different times on three specimens. Intraobserver and interobserver variability of the landmarks and the intraclass correlation coefficient (ICC) of the resulting axes and joint angles were evaluated. Results: Overall, the intraobserver and interobserver variability was low, with a mean deviation <5 mm for all landmarks. The ICC of all joint angles and axis deviations was >0.8, except for tibial torsion (ICC = 0.69). All knee joint angles showed excellent ICC (>0.95). Conclusions: Using the defined landmarks, a standardized 3D alignment assessment with low intraobserver and interobserver variability and high ICC values for the knee joint angles can be performed regardless of examiner's experience. The described method serves as a reliable standardized protocol for a 3D malalignment test of the lower limb. Three-dimensional pre-operative analysis might enhance understanding of deformities and lead to a new focus in surgical planning. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:185 / 193
页数:9
相关论文
共 50 条
  • [1] Three-dimensional assessment of lower limb alignment: Reference values and sex-related differences
    Degen, N.
    Sass, J.
    Jalali, J.
    Kovacs, L.
    Euler, E.
    Prall, W. C.
    Boecker, W.
    Thaller, P. H.
    Fuermetz, J.
    KNEE, 2020, 27 (02) : 428 - 435
  • [2] Radiological assessment of lower limb alignment
    Luis, Nuno Marques
    Varatojo, Ricardo
    EFORT OPEN REVIEWS, 2021, 6 (06) : 487 - 494
  • [3] Three-dimensional reconstruction of the lower limb from biplanar calibrated radiographs
    Quijano, S.
    Serrurier, A.
    Aubert, B.
    Laporte, S.
    Thoreux, P.
    Skalli, W.
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (12) : 1703 - 1712
  • [4] High three-dimensional accuracy of component placement and lower limb alignment using a robotic arm-assisted system and gap-balancing instrument in total knee arthroplasty
    Diquattro, Emanuele
    Prill, Robert
    Salzmann, Mikhail
    Traina, Francesco
    Becker, Roland
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2024, 32 (03) : 685 - 692
  • [5] Three-dimensional assessment of patellofemoral anatomy: Reliability and reference ranges
    Fuermetz, J.
    Daniel, T.
    Sass, J.
    Bergstraesser, M.
    Degen, N.
    Suero, E.
    Ahrens, P.
    Keppler, A. M.
    Boecker, W.
    Thaller, P. H.
    Prall, W. C.
    KNEE, 2021, 29 : 271 - 279
  • [6] Preoperative planning of total knee arthroplasty: reliability of axial alignment using a three-dimensional planning approach
    Tiefenboeck, Stefan
    Sesselmann, Stefan
    Taylor, Dominic
    Forst, Raimund
    Seehaus, Frank
    ACTA RADIOLOGICA, 2022, 63 (08) : 1051 - 1061
  • [7] Three-dimensional lower extremity alignment assessment system - Application to evaluation of component position after total knee arthroplasty
    Sato, T
    Koga, Y
    Omori, G
    JOURNAL OF ARTHROPLASTY, 2004, 19 (05) : 620 - 628
  • [8] Limb deformities and three-dimensional ultrasound
    Kos, M
    Hafner, T
    Funduk-Kurjak, B
    Bozek, T
    Kurjak, A
    JOURNAL OF PERINATAL MEDICINE, 2002, 30 (01) : 40 - 47
  • [9] Automatic alignment for three-dimensional tomographic reconstruction
    van Leeuwen, Tristan
    Maretzke, Simon
    Batenburg, K. Joost
    INVERSE PROBLEMS, 2018, 34 (02)
  • [10] Three-Dimensional Accuracy of Guided Implant Placement: Indirect Assessment of Clinical Outcomes
    Platzer, Susanne
    Bertha, Georg
    Heschl, Alexander
    Wegscheider, Walther A.
    Lorenzoni, Martin
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (05) : 724 - 734