Comprehensive two-dimensional chromatography with coupling of reversed phase high performance liquid chromatography and supercritical fluid chromatography

被引:29
作者
Stevenson, Paul G. [1 ]
Tarafder, Abhijit [1 ]
Guiochon, Georges [1 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
关键词
Supercritical fluid chromatography; Reversed phase HPLC; Two dimensional; Off-line; Fragrant oil; STATIONARY PHASES; PEAK-CAPACITY; SEPARATIONS;
D O I
10.1016/j.chroma.2011.11.020
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A 2D comprehensive chromatographic separation of blackberry sage fragrant oil was performed by using HPLC in the first dimension and SFC in the second. AC(18)-bonded silica column eluted with an ACN gradient was used in the HPLC dimension and an amino-bonded silica column eluted with ACN as a modifier in the SFC dimension. This 2D separation was completed in the off-line mode, the fractions from the HPLC column being collected and injected in the SFC column. The retention factors on the two columns have a -0.757 correlation coefficient. The method provides a practical peak capacity of 2400 in 280 min. The first eluted peaks in HPLC are the last ones eluted in SFC and vice versa. The results demonstrate that the coupling of an HPLC and an SFC separation have a great potential for 2D chromatographic separations. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:175 / 178
页数:4
相关论文
共 14 条
  • [1] Minimizing UV noise in supercritical fluid chromatography. I. Improving back pressure regulator pressure noise
    Berger, Terry A.
    Berger, Blair K.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (16) : 2320 - 2326
  • [2] Approaches to comprehensive multidimensional liquid chromatography systems
    Fairchild, Jacob N.
    Horvath, Krisztian
    Guiochon, Georges
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (09) : 1363 - 1371
  • [3] Construction of a new interface for comprehensive supercritical fluid chromatography x reversed phase liquid chromatography (SFC x RPLC)
    Francois, Isabelle
    Pereira, Alberto dos Santos
    Lynen, Frederic
    Sandra, Pat
    [J]. JOURNAL OF SEPARATION SCIENCE, 2008, 31 (19) : 3473 - 3478
  • [4] Comprehensive supercritical fluid chromatography x reversed phase liquid chromatography for the analysis of the fatty acids in fish oil
    Francois, Isabelle
    Sandra, Pat
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (18) : 4005 - 4012
  • [5] Implications of column peak capacity on the separation of complex peptide mixtures in single- and two-dimensional high-performance liquid chromatography
    Gilar, M
    Daly, AE
    Kele, M
    Neue, UD
    Gebler, JC
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1061 (02) : 183 - 192
  • [6] Two dimensional reversed-phase-reversed-phase separations -: Isomeric separations incorporating C18 and carbon clad zirconia stationary phases
    Gray, M
    Dennis, GR
    Wormell, P
    Shalliker, RA
    Slonecker, P
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 975 (02) : 285 - 297
  • [7] Guiochon G., 2011, J CHROMATOGR A, V1218, P1114
  • [8] Implementations of two-dimensional liquid chromatography
    Guiochon, Georges
    Marchetti, Nicola
    Mriziq, Khaled
    Shalliker, R. Andrew
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1189 (1-2) : 109 - 168
  • [9] GEOMETRIC APPROACH TO FACTOR-ANALYSIS FOR THE ESTIMATION OF ORTHOGONALITY AND PRACTICAL PEAK-CAPACITY IN COMPREHENSIVE 2-DIMENSIONAL SEPARATIONS
    LIU, ZY
    PATTERSON, DG
    LEE, ML
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (21) : 3840 - 3845
  • [10] The assessment of π-π selective stationary phases for two-dimensional HPLC analysis of foods: Application to the analysis of coffee
    Mnatsakanyan, Mariam
    Stevenson, Paul G.
    Shock, David
    Conlan, Xavier A.
    Goodie, Tiffany A.
    Spencer, Kylie N.
    Barnett, Neil W.
    Francis, Paul S.
    Shalliker, R. Andrew
    [J]. TALANTA, 2010, 82 (04) : 1349 - 1357