TRANSIENT CRITICAL HEAT FLUXES OF SUBCOOLED WATER FLOW BOILING IN A SUS304-CIRCULAR TUBE WITH VARIOUS TWISTED-TAPE INSERTS (Influence of Twist Ratio)

被引:0
|
作者
Hata, Koichi [1 ]
Shirai, Yasuyuki [2 ]
Masuzaki, Suguru [3 ]
机构
[1] Kyoto Univ, Inst Adv Energy, Kyoto 6110011, Japan
[2] Kyoto Univ, Dept Energy Sci & Technol, Sakyo Ku, Kyoto 6068501, Japan
[3] Natl Inst Nat Sci, Natl Inst Fus Sci, Toki, Gifu 5095292, Japan
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The transient critical heat fluxes in SUS304-circular tubes with various twisted-tape inserts are systematically measured for mass velocities (G=3988 to 13620 kg/m(2)s), inlet liquid temperatures (T-in =287.55 to 313.14 K), outlet pressures (P-out=805.11 to 870.23 kPa) and exponentially increasing heat inputs (Q=Q(0)exp(t/tau), tau=28.39 ms to 8.43 s) by the experimental water loop comprised of a multistage canned-type circulation pump controlled by an inverter. The SUS304-circular tube of inner diameter (d=6 mm), heated length (L=59.4 mm), effective length (L-eff=49.4 mm), L/d (=9.9), L-eff/d (=8.23) and wall thickness (delta=0.5 mm) with average surface roughness (Ra=3.89 mu m) is used in this work. The SUS304 twisted tapes with twist ratios, y [=H/d=(pitch of 180 degrees rotation)/d], of 2.40 and 4.45 are used. The transient critical heat fluxes for SUS304-circular tubes with various twisted-tape inserts are compared with authors' transient CHIP data for the empty SUS304-circular tube and a SUS304-circular tube with twisted-tape of y=3.37, and the values calculated by authors' transient CHF correlations for the empty circular tube and the circular tube with twisted-tape insert. The influences of heating rate, twist ratio and swirl velocity on the transient CHIP are investigated into details and the widely and precisely predictable correlations of the transient CHIP against inlet and outlet subcoolings for the circular tubes with various twisted-tape inserts are given based on the experimental data. The correlations can describe the transient CHFs for SUS304-tubes with various twisted-tape inserts obtained in this work within - 27 to 7.9 % difference.
引用
收藏
页数:13
相关论文
共 33 条
  • [1] Transient Critical Heat Fluxes of Subcooled Water Flow Boiling in SUS304-Circular Tubes With Various Twisted-Tape Inserts (Influence of Twist Ratio)
    Hata, Koichi
    Fukuda, Katsuya
    Masuzaki, Suguru
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2014, 6 (03)
  • [2] TRANSIENT CRITICAL HEAT FLUXES OF SUBCOOLED WATER FLOW BOILING IN A SHORT SUS304-TUBE WITH TWISTED-TAPE INSERT
    Hata, Koichi
    Shirai, Yasuyuki
    Masuzaki, Suguru
    PROCEEDINGS OF THE 20TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING AND THE ASME 2012 POWER CONFERENCE - 2012, VOL 3, 2012, : 125 - 137
  • [3] Heat transfer and critical heat flux of subcooled water flow boiling in a SUS304-tube with twisted-tape insert
    Hata K.
    Masuzaki S.
    Journal of Thermal Science and Engineering Applications, 2011, 3 (01)
  • [4] HEAT TRANSFER AND CRITICAL HEAT FLUX OF SUBCOOLED WATER FLOW BOILING IN A SUS304-TUBE WITH TWISTED-TAPE INSERT
    Hata, Koichi
    Masuzaki, Suguru
    PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 1: BIO HEAT TRANSFER, BOILING HEAT TRANSFER, COMPUTATIONAL HEAT TRANSFER, 2010, : 201 - 213
  • [5] Subcooled Water Flow Boiling Heat Transfer in a Short SUS304-Tube With Twisted-Tape Insert
    Hata, Koichi
    Masuzaki, Suguru
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2011, 133 (05):
  • [6] SUBCOOLED WATER FLOW BOILING HEAT TRANSFER IN A SHORT SUS304-TUBE WITH TWISTED-TAPE INSERT
    Hata, Koichi
    Masuzaki, Suguru
    PROCEEDINGS OF THE 18TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING 2010, VOL 4 PTS A AND B, 2011, : 355 - +
  • [7] Subcooled flow boiling heat transfer of water in circular tubes with twisted-tape inserts under high heat fluxes
    Yan, Jianguo
    Bi, Qincheng
    Cai, Laizhong
    Zhu, Ge
    Yuan, Qizheng
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2015, 68 : 11 - 21
  • [8] Transient critical heat fluxes of subcooled water flow boiling in a SUS304-circular tube caused by a rapid decrease in velocity from non-boiling regime
    Hata, Koichi
    Fukuda, Katsuya
    Masuzaki, Suguru
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2015, 66 : 160 - 172
  • [9] TRANSIENT CRITICAL HEAT FLUXES OF SUBCOOLED WATER FLOW BOILING IN A SUS304-CIRCULAR TUBE CAUSED BY A RAPID DECREASE IN VELOCITY FROM NON-BOILING REGIME
    Hata, Koichi
    Fukuda, Katsuya
    Masuzaki, Suguru
    PROCEEDINGS OF THE 22ND INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2014, VOL 2A, 2014,
  • [10] Critical heat flux and pressure drop of subcooled flow boiling in small-diameter tubes with twisted-tape inserts
    Tong, W
    Bergles, AE
    Jensen, MK
    JOURNAL OF ENHANCED HEAT TRANSFER, 1996, 3 (02) : 95 - 108