Validation of the Braun BP 3550 wrist blood pressure measuring device with a position sensor and an EasyClick cuff according to the International Protocol in adults

被引:6
|
作者
Iliman, Nevzat
Altunkan, Sekip
Kayaturk, Nur
Altunkan, Erkan
机构
[1] Metropol Med Ctr, Div Hypertens, TR-06400 Ankara, Turkey
[2] Diskapi Yildirim Beyazit Educ & Res Hosp, Dept Internal Med, Ankara, Turkey
关键词
blood pressure measurement; Braun BP 3550; validation; wrist monitors;
D O I
10.1097/01.mbp.0000218006.80827.dc
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective Among the electronic blood pressure measuring devices used for self-measurement of blood pressure by patients, models that measure at the wrist are becoming increasingly popular. Validation studies done with these equipments, however, are quite few. The objective of this study was to evaluate the accuracy of the Braun BP 3550 wrist blood pressure device against the mercury sphygmomanometer in adults according to the International Protocol criteria. Methods Fifty-four patients over 30 years of age were studied and classified on the basis of the range of the International Protocol. Blood pressure measurements at the wrist with the Braun BP 3550 were compared with the results obtained by two trained observers using a mercury sphygmomanometer. Nine sequential blood pressure measurements were taken. A total of 33 individuals with randomly distributed arm circumferences were selected for the validation study. During the validation study, 99 measurements were obtained for comparison from 33 individuals. The first phase was performed on 15 individuals and if the device passed this phase, 18 more individuals were selected. Results Mean discrepancies and standard deviations of the device sphygmomanometer were 0.4 +/- 8.1 mmHg for systolic blood pressure and 2.1 +/- 5.8 mmHg for diastolic blood pressure in the study group. The device passed phase 1 in 15 individuals. In phase 2.1, from the total 99 comparisons, 65, 84 and 91 for systolic blood pressure and 62, 91 and 98 for diastolic blood pressure were <5, < 10 and < 15 mmHg, respectively. In phase 2.2, 23 individuals had at least two of the differences within 5 mmHg, and two had no differences within 5 mmHg for systolic blood pressure. In terms of diastolic blood pressure, 23 individuals had at least two of the differences within 5 mmHg and three had no differences within 5 mmHg. Braun BP 3550 passed phases 2.1 and 2.2 in the adult participants. Conclusion The Braun BP 3550 wrist blood pressure device passed according to the International Protocol criteria and can be recommended for use in adults. Deviation from the average value, however, was greater in patients with high systolic blood pressure as compared with those with lower blood pressure.
引用
收藏
页码:45 / 49
页数:5
相关论文
共 50 条
  • [41] Validation of the Microlife BPA100 Plus device for self-home blood pressure measurement according to the International Protocol
    Stergiou, George S.
    Giovas, Periklis R.
    Neofytou, Michalis S.
    Adamopoulos, Dionysios N.
    BLOOD PRESSURE MONITORING, 2006, 11 (03) : 157 - 160
  • [42] Validation of the A&D UM-101 professional hybrid device for office blood pressure measurement according to the International Protocol
    Stergiou, George S.
    Giovas, Periklis P.
    Gkinos, Charilaos P.
    Tzamouranis, Dimitris G.
    BLOOD PRESSURE MONITORING, 2008, 13 (01) : 37 - 42
  • [43] Validation of the blood pressure measurement device Beurer BM 28 according to the European Society of Hypertension International Protocol revision 2010
    Deutsch, Cornelia
    Bramlage, Carsten
    Botta, Beate
    Krueger, Ralf
    Forstner, Klaus
    Bramlage, Peter
    Beime, Beate
    BLOOD PRESSURE MONITORING, 2021, 26 (04) : 292 - 298
  • [44] Validation of the AVITA BPM15S wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010
    Kang, Yuan-Yuan
    Zeng, Wei-Fang
    Zhang, Lu
    Li, Yan
    Wang, Ji-Guang
    BLOOD PRESSURE MONITORING, 2014, 19 (03) : 183 - 186
  • [45] Validation of the Microlife BP3T01-1B blood pressure monitoring device in adults and adolescents according to the ISO 81060-2:2018 protocol
    Botta, Beate
    Bramlage, Carsten
    Hachaturyan, Violetta
    Jost, Lena
    Bramlage, Peter
    BLOOD PRESSURE MONITORING, 2025, 30 (02) : 86 - 92
  • [46] Validation of the TRANSTEK blood pressure monitor TMB-986 for home blood pressure monitoring according to the International Protocol
    Liu, Wen Jun
    Li, Su Gang
    Song, Zhe
    Gong, Wei
    BLOOD PRESSURE MONITORING, 2010, 15 (05) : 278 - 280
  • [47] Validation of the Tel-O-GRAPH, a new oscillometric blood pressure-measuring device, according to the British Hypertension Society protocol
    Reshetnik, Alexander
    Gohlisch, Christopher
    Zidek, Walter
    Toelle, Markus
    van der Giet, Markus
    BLOOD PRESSURE MONITORING, 2016, 21 (05) : 307 - 309
  • [48] Validation of the HEM-780REL with easy wrap cuff for self-measurement of blood pressure according to the European Society of Hypertension International Protocol
    Viera, Anthony J.
    Hinderliter, Alan L.
    BLOOD PRESSURE MONITORING, 2007, 12 (05) : 335 - 338
  • [49] Validation of four automatic devices for self-measurement of blood pressure according to the international protocol of the European Society of Hypertension
    Topouchian, Jirar
    Agnoletti, Davide
    Blacher, Jacques
    Youssef, Ahmed
    Ibanez, Isabel
    Khabouth, Jose
    Khawaja, Salwa
    Beaino, Layale
    Asmar, Roland
    VASCULAR HEALTH AND RISK MANAGEMENT, 2011, 7 : 709 - 717
  • [50] Validation of the SEJOY BP-1307 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010
    Lei, Lei
    Chen, Yi
    Chen, Qi
    Li, Yan
    Wang, Ji-Guang
    BLOOD PRESSURE MONITORING, 2017, 22 (06) : 371 - 374