Posterior capsule opacification and Nd:YAG capsulotomy rates after implantation of silicone, hydrogel and soft acrylic intraocular lenses:: a two-year follow-up study

被引:20
作者
Beltrame, G [1 ]
Salvetat, ML [1 ]
Chizzolini, M [1 ]
Driussi, GB [1 ]
Busatto, P [1 ]
Di Giorgio, G [1 ]
Barosco, F [1 ]
机构
[1] Osped San Dona Piave, Unita Operativa Oculist, I-30027 Venice, Italy
关键词
intraocular lens; posterior capsule opacification; Nd : YAG laser posterior capsulotomy;
D O I
10.1177/112067210201200508
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To compare the posterior capsule opacification (PCO) and neodymium:YAG (Nd:YAG) laser posterior capsulotomy rates associated with three different posterior chamber foldable intraocular lenses (IOL). METHODS. We retrospectively evaluated the rates of PCO and Nd:YAG laser capsulotomy in 1150 eyes two years after standard phacoemulsification with a no-stitch 3.5mm clear corneal incision (CCl) and in-the-bag implantation of one of three types of IOL: 190 eyes received a one-piece round-edged hydrogel IOL (Hydroview H60M, Bausch Lomb); 475 eyes a three-piece round-edged silicone IOL (AMO PhacoFlex SI-40NB, Allergan); 485 eyes a three-piece square-edged soft acrylic lens (AcrySof MA60MA, Alcon). RESULTS. The PCO and Nd:YAG laser capsulotomy rates were respectively 43.15% and 20.5% in the Hydroview H60M group, 27.57% and 9.68% in the AMO PhacoFlex SI-40NB group, 10.5% and 2.47% in the AcrySof MA60MA group. CONCLUSIONS. PCO and Nd:YAG laser capsulotomy rates were significantly higher in the Hydroview H60M group and significantly lower with the AcrySof MA60MA lenses, which combine a bioactive constitutive material with the square-edged optic design.
引用
收藏
页码:388 / 394
页数:7
相关论文
共 45 条
[1]   CELLULAR INVASION ON HYDROGEL AND POLY(METHYL METHACRYLATE) IMPLANTS AN INVIVO STUDY [J].
AMON, M ;
MENAPACE, R .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (06) :774-779
[2]   POSTERIOR CAPSULE OPACIFICATION [J].
APPLE, DJ ;
SOLOMON, KD ;
TETZ, MR ;
ASSIA, EI ;
HOLLAND, EY ;
LEGLER, UFC ;
TSAI, JC ;
CASTANEDA, VE ;
HOGGATT, JP ;
KOSTICK, AMP .
SURVEY OF OPHTHALMOLOGY, 1992, 37 (02) :73-116
[3]   COMPLICATIONS OF INTRAOCULAR LENSES - A HISTORICAL AND HISTOPATHOLOGICAL REVIEW [J].
APPLE, DJ ;
MAMALIS, N ;
LOFTFIELD, K ;
GOOGE, JM ;
NOVAK, LC ;
KAVKAVANNORMAN, D ;
BRADY, SE ;
OLSON, RJ .
SURVEY OF OPHTHALMOLOGY, 1984, 29 (01) :1-54
[4]  
Aron-Rosa D S, 1984, J Am Intraocul Implant Soc, V10, P35
[5]   MULTICENTER TRIAL OF AN INTRAOCULAR HYDROGEL LENS IMPLANT [J].
BARRETT, GD ;
BEASLEY, H ;
LORENZETTI, OJ ;
ROSENTHAL, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1987, 13 (06) :621-626
[6]   Effect of intraocular lens and anterior capsule opening type on posterior capsule opacification [J].
Birinci, H ;
Kuruoglu, S ;
Öge, I ;
Öge, F ;
Acar, E .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (08) :1140-1146
[7]   EFFECT OF INTRAOCULAR-LENS OPTIC DESIGN ON POSTERIOR CAPSULAR OPACIFICATION [J].
BORN, CP ;
RYAN, DK .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (02) :188-192
[8]   MANAGEMENT OF THE POSTERIOR CAPSULE DURING PEDIATRIC INTRAOCULAR-LENS IMPLANTATION [J].
BUCKLEY, EG ;
KLOMBERS, LA ;
SEABER, JH ;
SCALISEGORDY, A ;
MINZTER, R .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1993, 115 (06) :722-728
[9]   COMPREHENSIVE STUDY OF DAMAGE TO INTRAOCULAR LENSES BY SINGLE AND MULTIPLE NANOSECOND NEODYMIUM - YAG LASER-PULSES [J].
CAPON, MRC ;
DOCCHIO, F ;
LEONI, G ;
TRABUCCHI, G ;
BRANCATO, R .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (05) :603-610
[10]   Intraocular lens materials and styles: A review [J].
Chehade, M ;
Elder, MJ .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1997, 25 (04) :255-263