Nanowire transistor arrays for mapping neural circuits in acute brain slices

被引:153
作者
Qing, Quan [2 ]
Pal, Sumon K. [1 ]
Tian, Bozhi [2 ]
Duan, Xiaojie [2 ]
Timko, Brian P. [2 ]
Cohen-Karni, Tzahi [3 ]
Murthy, Venkatesh N. [1 ]
Lieber, Charles M. [2 ,3 ]
机构
[1] Harvard Univ, Ctr Brain Sci, Cambridge, MA 02138 USA
[2] Harvard Univ, Dept Chem & Biol Chem, Cambridge, MA 02138 USA
[3] Harvard Univ, Sch Engn & Appl Sci, Cambridge, MA 02138 USA
关键词
multiplexed recording; nanodevice; neuron; patch clamp; silicon; ELECTRICAL DETECTION; OLFACTORY-BULB; CORTEX; ORGANIZATION; STIMULATION; INHIBITION; POTENTIALS;
D O I
10.1073/pnas.0914737107
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Revealing the functional connectivity in natural neuronal networks is central to understanding circuits in the brain. Here, we show that silicon nanowire field-effect transistor (Si NWFET) arrays fabricated on transparent substrates can be reliably interfaced to acute brain slices. NWFET arrays were readily designed to record across a wide range of length scales, while the transparent device chips enabled imaging of individual cell bodies and identification of areas of healthy neurons at both upper and lower tissue surfaces. Simultaneous NWFET and patch clamp studies enabled unambiguous identification of action potential signals, with additional features detected at earlier times by the nanodevices. NWFET recording at different positions in the absence and presence of synaptic and ion-channel blockers enabled assignment of these features to presynaptic firing and postsynaptic depolarization from regions either close to somata or abundant in dendritic projections. In all cases, the NWFET signal amplitudes were from 0.3-3 mV. In contrast to conventional multielectrode array measurements, the small active surface of the NWFET devices, similar to 0.06 mu m(2), provides highly localized multiplexed measurements of neuronal activities with demonstrated sub-millisecond temporal resolution and, significantly, better than 30 mu m spatial resolution. In addition, multiplexed mapping with 2D NWFET arrays revealed spatially heterogeneous functional connectivity in the olfactory cortex with a resolution surpassing substantially previous electrical recording techniques. Our demonstration of simultaneous high temporal and spatial resolution recording, as well as mapping of functional connectivity, suggest that NWFETs can become a powerful platform for studying neural circuits in the brain.
引用
收藏
页码:1882 / 1887
页数:6
相关论文
共 40 条
[1]   The hippocampal lamella hypothesis revisited [J].
Andersen, P ;
Soleng, AF ;
Raastad, M .
BRAIN RESEARCH, 2000, 886 (1-2) :165-171
[2]   Instrumentation to evaluate neural signal recording properties of micromachined microelectrodes inserted in invertebrate nerve [J].
Banks, DJ ;
Balachandran, W ;
Richards, PR ;
Ewins, D .
PHYSIOLOGICAL MEASUREMENT, 2002, 23 (02) :437-448
[3]   CNQX BLOCKS ACIDIC AMINO-ACID INDUCED DEPOLARIZATIONS AND SYNAPTIC COMPONENTS MEDIATED BY NON-NMDA RECEPTORS IN RAT HIPPOCAMPAL SLICES [J].
BLAKE, JF ;
BROWN, MW ;
COLLINGRIDGE, GL .
NEUROSCIENCE LETTERS, 1988, 89 (02) :182-186
[4]  
Cellot G, 2009, NAT NANOTECHNOL, V4, P126, DOI [10.1038/NNANO.2008.374, 10.1038/nnano.2008.374]
[5]   Flexible electrical recording from cells using nanowire transistor arrays [J].
Cohen-Karni, Tzahi ;
Timko, Brian P. ;
Weiss, Lucien E. ;
Lieber, Charles M. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2009, 106 (18) :7309-7313
[6]   FIBER TRAJECTORIES OF OLFACTORY BULB EFFERENTS IN HAMSTER [J].
DEVOR, M .
JOURNAL OF COMPARATIVE NEUROLOGY, 1976, 166 (01) :31-48
[7]   Two-dimensional monitoring of spiking networks in acute brain slices [J].
Egert, U ;
Heck, D ;
Aertsen, A .
EXPERIMENTAL BRAIN RESEARCH, 2002, 142 (02) :268-274
[8]   Action potentials of HL-1 cells recorded with silicon nanowire transistors [J].
Eschermann, Jan Felix ;
Stockmann, Regina ;
Hueske, Martin ;
Vu, Xuan Thang ;
Ingebrandt, Sven ;
Offenhaeusser, Andreas .
APPLIED PHYSICS LETTERS, 2009, 95 (08)
[9]   Microelectronic system for high-resolution mapping of extracellular electric fields applied to brain slices [J].
Frey, U. ;
Egert, U. ;
Heer, F. ;
Hafizovic, S. ;
Hierlemann, A. .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (07) :2191-2198
[10]   VSDI: A new era in functional imaging of cortical dynamics [J].
Grinvald, A ;
Hildesheim, R .
NATURE REVIEWS NEUROSCIENCE, 2004, 5 (11) :874-885