A monosegmented-flow Karl Fischer titrator

被引:11
作者
de Aquino, Emerson Vidal [1 ]
Rodrigues Rohwedder, Jarbas Jose [1 ]
Pasquini, Celio [1 ]
机构
[1] Univ Estadual Campinas, Inst Quim, BR-13084971 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
water determination; mechanized titration; monosegmented analysis; Karl Fischer titration; flow-batch analysis; ethanol; methanol;
D O I
10.1016/j.talanta.2006.06.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A monosegmented volumetric Karl Fischer titrator is described to mechanize the determination of water content in organic solvents. The system is based on the flow-batch characteristics of the monosegmented analysis concept and employs biamperometry to monitor the progress of the titration. The system shows accuracy and precision that are highly independent of the flow rate, does not require calibration, and is carried out in a closed system capable of minimizing contact of the sample and reagents with ambient moisture. Sample volumes in the range of 40-300 mu L are employed, depending on the water concentration. An automatic dilution is provided to deal with concentrated samples. The consumption of Karl Fischer reagent depends on the water content of the sample but is not larger than 100 mu L. The system was evaluated for determination of water in ethanol and methanol in the range 0.02-0.5% (w/w). The average relative precision estimated in that range (9-3%) is comparable to that obtained with a larger volume commercial system and no significant difference was observed between the results obtained for the two systems at the 95% confidence level. A complete titration can be performed in less than 5 min employing the proposed system. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1288 / 1293
页数:6
相关论文
共 19 条
[1]   Automatic stepwise potentiometric titration in a monosegmented flow system [J].
Borges, EP ;
Martelli, PB ;
Reis, BF .
MIKROCHIMICA ACTA, 2000, 135 (3-4) :179-184
[2]   Simultaneous multiple injection in monosegmented flow analysis [J].
Brito, VO ;
Raimundo, IM .
ANALYTICA CHIMICA ACTA, 1998, 371 (2-3) :317-+
[3]   FLOW-INJECTION TITRATION - LINEAR OR LOGARITHMIC [J].
CHEN, R ;
RUZICKA, J ;
CHRISTIAN, GD .
TALANTA, 1994, 41 (06) :949-955
[4]   Monosegmented flow titrator [J].
de Aquino, EV ;
Rohwedder, JJR ;
Pasquini, C .
ANALYTICA CHIMICA ACTA, 2001, 438 (1-2) :67-74
[5]  
DEAQUINO EV, 2006, UNPUB ABC
[6]   DETERMINATION OF WATER BY FLOW-INJECTION ANALYSIS USING FISCHER,KARL REAGENT WITH ELECTROCHEMICAL DETECTION [J].
ESCOTT, REA ;
TAYLOR, AF .
ANALYST, 1985, 110 (07) :847-849
[7]   Automated potentiometric titrator based in monosegmented flow system. [J].
Ganzarolli, EM ;
Lehmkuhl, A ;
de Queiróz, RRR ;
de Souza, IG .
QUIMICA NOVA, 1999, 22 (01) :53-57
[8]   A flow-batch titrator exploiting a one-dimensional optimisation algorithm for end point search [J].
Honorato, RS ;
Araújo, MCU ;
Lima, RAC ;
Zagatto, EAG ;
Lapa, RAS ;
Lima, JLFC .
ANALYTICA CHIMICA ACTA, 1999, 396 (01) :91-97
[9]   DETERMINATION OF WATER BY FLOW-INJECTION ANALYSIS WITH THE KARL FISCHER REAGENT [J].
KAGEVALL, I ;
ASTROM, O ;
CEDERGREN, A .
ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) :199-208
[10]   DETERMINATION OF WATER IN ORGANIC-SOLVENTS BY FLOW-INJECTION ANALYSIS WITH KARL FISCHER REAGENT AND A BIAMPEROMETRIC DETECTION SYSTEM [J].
LIANG, C ;
VACHA, P ;
VANDERLINDEN, WE .
TALANTA, 1988, 35 (01) :59-61