Evaluation of two novel aluminum-free, zinc-based glass polyalkenoate cements as alternatives to PMMA bone cement for use in vertebroplasty and balloon kyphoplasty

被引:15
|
作者
Lewis, Gladius [1 ]
Towler, Mark R. [2 ]
Boyd, Daniel [3 ]
German, Matthew J. [4 ]
Wren, Anthony W. [2 ]
Clarkin, Owen M. [2 ]
Yates, Andrew [4 ]
机构
[1] Univ Memphis, Dept Mech Engn, Memphis, TN 38152 USA
[2] Univ Limerick, Mat & Surface Sci Inst, Limerick, Ireland
[3] Cork Inst Technol, Med Engn Design Innovat Ctr, Cork, Ireland
[4] Newcastle Univ, Dent Mat Unit, Sch Dent Sci, Newcastle Upon Tyne NE2 4BW, Tyne & Wear, England
关键词
OSTEOPOROTIC VERTEBRAL FRACTURES; MECHANICAL-PROPERTIES; PERCUTANEOUS VERTEBROPLASTY; COMPRESSION FRACTURES; IONOMER CEMENTS; CANCELLOUS BONE; MANAGEMENT; AUGMENTATION; BIOACTIVITY; MODULUS;
D O I
10.1007/s10856-009-3845-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Vertebroplasty (VP) and balloon kyphoplasty (BKP) are now widely used for treating patients in whom the pain due to vertebral compression fractures is severe and has proved to be refractory to conservative treatment. These procedures involve percutaneous delivery of a bolus of an injectable bone cement either directly to the fractured vertebral body, VB (VP) or to a void created in it by an inflatable bone tamp (BKP). Thus, the cement is a vital component of both procedures. In the vast majority of VPs and BKPs, a poly(methyl methacrylate) (PMMA) bone cement is used. This material has many shortcomings, notably lack of bioactivity and very limited resorbability. Thus, there is room for alternative cements. We report here on two variants of a novel, bioactive, Al-free, Zn-based glass polyalkenoate cement (Zn-GPC), and how their properties compare to those of an injectable PMMA bone cement (SIMPL) that is widely used in VP and BKP. The properties determined were injectability, radiopacity, uniaxial compressive strength, and biaxial flexural modulus. In addition, we compared the compression fatigue lives of a validated synthetic osteoporotic VB model (a polyurethane foam cube with an 8 mm-diameter through-thickness cylindrical hole), at 0-2300 N and 3 Hz, when the hole was filled with each of the three cements. A critical review of the results suggests that the performance of each of the Zn-GPCs is comparable to that of SIMPL; thus, the former cements merit further study with a view to being alternatives to an injectable PMMA cement for use in VP and BKP.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 3 条
  • [1] Evaluation of two novel aluminum-free, zinc-based glass polyalkenoate cements as alternatives to PMMA bone cement for use in vertebroplasty and balloon kyphoplasty
    Gladius Lewis
    Mark R. Towler
    Daniel Boyd
    Matthew J. German
    Anthony W. Wren
    Owen M. Clarkin
    Andrew Yates
    Journal of Materials Science: Materials in Medicine, 2010, 21 : 59 - 66
  • [2] Comparison of antibacterial properties of commercial bone cements and fillers with a zinc-based glass polyalkenoate cement
    A. W. Wren
    N. M. Cummins
    M. R. Towler
    Journal of Materials Science, 2010, 45 : 5244 - 5251
  • [3] Comparison of antibacterial properties of commercial bone cements and fillers with a zinc-based glass polyalkenoate cement
    Wren, A. W.
    Cummins, N. M.
    Towler, M. R.
    JOURNAL OF MATERIALS SCIENCE, 2010, 45 (19) : 5244 - 5251