Separation and sample pre-treatment in bioanalysis using monolithic phases: A review

被引:78
作者
Saunders, Kenneth C. [3 ]
Ghanem, Ashraf [1 ,2 ]
Hon, Wei Boon [1 ,2 ]
Hilder, Emily F. [1 ,2 ]
Haddad, Paul R. [1 ,2 ]
机构
[1] Univ Tasmania, Sch Chem, ACROSS, Hobart, Tas 7001, Australia
[2] Univ Tasmania, Sch Chem, PARC, Hobart, Tas 7001, Australia
[3] Pfizer Global Res & Dev, Sandwich, Kent, England
关键词
Drug discovery; Bioanalysis; Plasma; Urine; Monolithic phases; Polymer monoliths; PERFORMANCE LIQUID-CHROMATOGRAPHY; TANDEM MASS-SPECTROMETRY; POROUS POLYMER MONOLITHS; THROUGHPUT QUANTITATIVE BIOANALYSIS; POLYCYCLIC AROMATIC-HYDROCARBONS; EXCHANGE STATIONARY PHASES; CAPILLARY COLUMNS; HUMAN PLASMA; SILICA COLUMNS; LC-MS/MS;
D O I
10.1016/j.aca.2009.05.043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In order to support drug discovery and development studies within the pharmaceutical industry there has been an increased use of innovative bioanalytical assays and associated analytical technology. Performing quantitative bioanalysis in a variety of biological matrices can also involve the use of sample preparation techniques, complex HLPC column switching and microfluidic systems. Development of assays for diverse therapeutic agents in biomatrices. such as plasma and urine, can be very technically challenging to obtain the sensitivity, speed and specificity required. This challenge focuses on the quantification of drugs and metabolites at very low concentration levels, in an excess of biological matrix and in a high-throughput manner. One area of wide interest is the use and application of monolithic phases where emerging technology has been implemented successfully. This review presents an overview of the application of monolithic phases in a bioanalytical setting, including the bioanalytical challenges that need to be overcome; the synthesis, use and applicability of monolithic phases (with emphasis on polymer-based phases); the currently available bioanalytical techniques and approaches; and future possibilities for these phases. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:22 / 31
页数:10
相关论文
共 111 条
  • [1] Evaluation of monolithic packed 96-tips and liquid chromatography-tandem mass spectrometry for extraction and quantification of pindolol and metoprolol in human plasma samples
    Abdel-Rehim, Mohamed
    Persson, Christina
    Altun, Zeki
    Blomberg, Lars
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1196 : 23 - 27
  • [2] Ackermann Bradley L., 2002, Current Topics in Medicinal Chemistry, V2, P53, DOI 10.2174/1568026023394605
  • [3] Current Applications of Liquid Chromatography/Mass Spectrometry in Pharmaceutical Discovery After a Decade of Innovation
    Ackermann, Bradley L.
    Berna, Michael J.
    Eckstein, James A.
    Ott, Lee W.
    Chaudhary, Ajai K.
    [J]. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, 2008, 1 (357-396) : 357 - 396
  • [4] Development and application of a new on-line SPE system combined with LC-MS/MS detection for high throughput direct analysis of pharmaceutical compounds in plasma
    Alnouti, Y
    Srinivasan, K
    Waddell, D
    Bi, HG
    Kavetskaia, O
    Gusev, AI
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1080 (02) : 99 - 106
  • [5] Evaluation of monolithic packed 96-tips for solid-phase extraction of local anesthetics from human plasma for quantitation by liquid chromatography tandem mass spectrometry
    Altun, Zeki
    Hjelmstrom, Anette
    Blomberg, Lars G.
    Abdel-Rehim, Mohamed
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2008, 31 (05) : 743 - 751
  • [6] Surface modified polypropylene pipette tips packed with a monolithic plug of adsorbent for high-throughput sample preparation
    Altun, Zeki
    Hjelmstrom, Anette
    Abdel-Rehim, Mohamed
    Blomberg, Lars G.
    [J]. JOURNAL OF SEPARATION SCIENCE, 2007, 30 (12) : 1964 - 1972
  • [7] Increasing sample preparation throughput using monolithic methacrylate polymer as packing material for 96-tip robotic device
    Altun, Zeki
    Blomberg, Lars G.
    Abdel-Rehim, Mohamed
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2006, 29 (10) : 1477 - 1489
  • [8] Poly(glycerin 1,3-dimethacrylate)-based monolith with a bicontinuous structure tailored as HPLC column by photoinitiated in situ radical polymerization via viscoelastic phase separation
    Aoki, Hiroshi
    Tanaka, Nobuo
    Kubo, Takuya
    Hosoya, Ken
    [J]. JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 2008, 46 (14) : 4651 - 4673
  • [9] Bakhtiar R, 2002, J LIQ CHROMATOGR R T, V25, P507, DOI 10.1081/JLC-120003344
  • [10] High-throughput selected reaction monitoring liquid chromatography-mass spectrometry determination of methylphenidate and its major metabolite, ritalinic acid, in rat plasma employing monolithic columns
    Barbarin, N
    Mawhinney, DB
    Black, R
    Henion, J
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 783 (01): : 73 - 83