Placement of phasor measurement unit for complete observability of an isolated microgrid system

被引:2
|
作者
Ghosh, Suman [1 ]
Das, J. K. [1 ]
Chanda, Chandan Kr [2 ]
机构
[1] GNIT, Dept Elect Engn, Kolkata, India
[2] IIEST, Dept Elect Engn, Kolkata, India
关键词
12;
D O I
10.1007/s00542-019-04385-4
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The role of the microgrid to meet up the localized power demand is of immense importance considering the growing power demand as well as grid inadequacy in Indian power scenario. Apart from meeting localized power demand with various distributed generating sources microgrid can render support to the adjacent main grid or similar localized grid as when needed. This paper presents the techniques for identifying placement sites for Phasor Measurement Units (PMUs) in a microgrid system based on complete observability of the system. The main objective of optimal placement of PMU problem is to determine a minimal set of PMUs such that the whole system is observable. This study has been done on a 14 bus test model with the help of PSAT.
引用
收藏
页码:4671 / 4674
页数:4
相关论文
共 50 条
  • [1] Placement of phasor measurement unit for complete observability of an isolated microgrid system
    Suman Ghosh
    J. K. Das
    Chandan Kr. Chanda
    Microsystem Technologies, 2019, 25 : 4671 - 4674
  • [2] Phasor measurement unit placement techniques for complete and incomplete observability
    Nuqui, RF
    Phadke, AG
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (04) : 2381 - 2388
  • [3] System Redundancy Index based Optimized Phasor Measurement Unit Placement for Complete Network Observability
    Awon, Muhammad
    Butt, Hassan Zahid
    Khalid, Hassan Abdullah
    Janjua, Abdul Kashif
    2018 4TH INTERNATIONAL CONFERENCE ON POWER GENERATION SYSTEMS AND RENEWABLE ENERGY TECHNOLOGIES (PGSRET-2018), 2018, : 181 - 185
  • [4] Minimum Phasor Measurement Unit Placement For Partial Observability of Power System
    Mohamud, Abdishakur Mohamed
    Wu, Jing
    Long, Chengnian
    Li, Shaoyuan
    PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 10085 - 10089
  • [5] Phasor measurement unit placement based on incomplete observability
    Nuqui, RF
    Phadke, AG
    2002 IEEE POWER ENGINEERING SOCIETY SUMMER MEETING, VOLS 1-3, CONFERENCE PROCEEDINGS, 2002, : 888 - 893
  • [6] POWER-SYSTEM OBSERVABILITY WITH MINIMAL PHASOR MEASUREMENT PLACEMENT
    BALDWIN, TL
    MILI, L
    BOISEN, MB
    ADAPA, R
    IEEE TRANSACTIONS ON POWER SYSTEMS, 1993, 8 (02) : 707 - 715
  • [7] Optimal placement of phasor measurement units for power system observability
    Chakrabarti, Saikat
    Kyriakides, Elias
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2008, 23 (03) : 1433 - 1440
  • [8] Micro Phasor Measurement Unit (μPMU) Placement for Maximum Observability in Smart Distribution Network
    Hampannavar, Santoshkumar
    Deepa, B.
    Swapna, M.
    2021 IEEE PES/IAS POWERAFRICA CONFERENCE, 2021, : 570 - 574
  • [9] Optimal Placement of Phasor Measurement Unit for System Observability (Case Study: Southern Region Power System Network, Ethiopia)
    Negash, Kinfe
    Khan, Baseem
    Tesfaye, Damot
    Gayathri, M.
    2017 INTERNATIONAL CONFERENCE ON COMPUTING METHODOLOGIES AND COMMUNICATION (ICCMC), 2017, : 73 - 77
  • [10] Optimal phasor measurement unit placement for power system observability using teaching-learning based optimization
    Yuvaraju, V
    Thangavel, S.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 137