Superlubricious surface mimicking articular cartilage by grafting poly(2-methacryloyloxyethyl phosphorylcholine) on orthopaedic metal bearings

被引:34
作者
Kyomoto, Masayuki [1 ,2 ,3 ]
Moro, Toru [3 ,4 ]
Iwasaki, Yasuhiko [5 ]
Miyaji, Fumiaki [1 ]
Kawaguchi, Hiroshi [4 ]
Takatori, Yoshio [3 ,4 ]
Nakamura, Kozo [3 ]
Ishihara, Kazuhiko [2 ,6 ]
机构
[1] Japan Med Mat Corp, Res Dept, Osaka, Japan
[2] Univ Tokyo, Sch Engn, Dept Mat Engn, Tokyo, Japan
[3] Univ Tokyo, Sch Med, Div Sci Joint Reconstruct, Tokyo 113, Japan
[4] Univ Tokyo, Fac Med, Dept Orthopaed Surg, Tokyo, Japan
[5] Kansai Univ, Fac Chem Mat & Bioengn, Dept Chem & Mat Engn, Osaka, Japan
[6] Univ Tokyo, Ctr Nano Bio Integrat, Tokyo, Japan
关键词
joint replacement; metal surface treatment; photopolymerization; phosphorylcholine; hydrophilicity; TOTAL HIP-ARTHROPLASTY; CO-CR-MO; MOLECULAR-WEIGHT POLYETHYLENE; CROSS-LINKED POLYETHYLENE; 2-METHACRYLOYLOXYETHYL PHOSPHORYLCHOLINE; PROTEIN ADSORPTION; PHOSPHOLIPID POLYMERS; POLY(ETHYLENE GLYCOL); BIOCOMPATIBLE POLYMER; MECHANICAL-PROPERTIES;
D O I
10.1002/jbm.a.32280
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Aseptic loosening of the artificial hip joint with osteolysis due to the wear particles from polyethylene cup has remained as a serious issue. To reduce this wear and develop a novel artificial hip joint system, we produced a superlubricious metal-bearing material: for this, we grafted a 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer onto the surface of a cobalt-chromium-molybdenum (Co-Cr-Mo) alloy. For ensuring long-term benefit retention of poly(MPC) on the Co-Cr-Mo alloy for application as a novel artificial hip joint system, several issues must be considered: strong bonding between poly(MPC) and Co-Cr-Mo surface, high mobility of free end groups of the poly(MPC) layer, and high density, of the introduced poly(MPC). Considering these issues, we introduced a 3-methacryloxypropyl trimethoxysilane (MPSi) intermediate layer and a photoinduced graft polymerization technique to create a strong covalent bond between the Co-Cr-Mo substrate and the poly(MPC) chain via the MPSi layer. The thickness and density of the poly(MPC) layer on the surface increased with the MPC concentration and photoirradiation time. The grafted poly(MPC) layer successfully provided super-lubricity to the Co-Cr-Mo surface. The poly(MPC)-grafted crosslinked polyethylene/poly(MPC)-grafted Co-Cr-Mo or cartilage/poly(MPC)-grafted Co-Cr-Mo bearing interface mimicking natural joints showed an extremely low friction coefficient of 0.01, which is as low as that of natural cartilage interface. A superlubricious metal-bearing surface would enable the development of a novel biocompatible artificial hip joint system-artificial femoral head for partial hemiarthroplasty and metal-on-polymer/metal type for total hip arthroplasty. (C) 2008 Wiley Periodicals, Inc. J Biomed Mater Res 91A: 730-741, 2009
引用
收藏
页码:730 / 741
页数:12
相关论文
共 65 条
[1]  
*ASTM, 2004, ANN BOOK ASTM STAND, V13
[2]  
ASTM, 2004, ANN BOOK ASTM STAND, V13
[3]   Influence of hyaluronic acid on the time-dependent friction response of articular cartilage under different conditions [J].
Bell, CJ ;
Ingham, E ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H1) :23-31
[4]   'Severe' wear challenge to 'as-cast' and 'double heat-treated' large-diameter metal-on-metal hip bearings [J].
Bowsher, JG ;
Nevelos, J ;
Williams, PA ;
Shelton, JC .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H2) :135-143
[5]   Controlled/living radical polymerization: Features, developments, and perspectives [J].
Braunecker, Wade A. ;
Matyjaszewski, Krzysztof .
PROGRESS IN POLYMER SCIENCE, 2007, 32 (01) :93-146
[6]   Tribological study of lubricious DLC biocompatible coatings [J].
Brizuela, M ;
Garcia-Luis, A ;
Viviente, JL ;
Braceras, I ;
Oñate, JI .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2002, 13 (12) :1129-1133
[7]   Cytocompatibility of UV and visible light photoinitiating systems on cultured NIH/3T3 fibroblasts in vitro [J].
Bryant, SJ ;
Nuttelman, CR ;
Anseth, KS .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2000, 11 (05) :439-457
[8]   Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements [J].
Clarke, IC ;
Good, V ;
Williams, P ;
Schroeder, D ;
Anissian, L ;
Stark, A ;
Oonishi, H ;
Schuldies, J ;
Gustafson, G .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H4) :331-347
[9]   A hip joint simulator study of the performance of metal-on-metal joints - Part I: The role of materials [J].
Dowson, D ;
Hardaker, C ;
Flett, M ;
Isaac, GH .
JOURNAL OF ARTHROPLASTY, 2004, 19 (08) :118-123
[10]   Wear of surface engineered metal-on-metal hip prostheses [J].
Fisher, J ;
Hu, XQ ;
Stewart, TD ;
Williams, S ;
Tipper, JL ;
Ingham, E ;
Stone, MH ;
Davies, C ;
Hatto, P ;
Bolton, J ;
Riley, M ;
Hardaker, C ;
Isaac, GH ;
Berry, G .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2004, 15 (03) :225-235