A simple and rapid assay for heparanase activity using homogeneous time-resolved fluorescence

被引:31
|
作者
Enomoto, K [1 ]
Okamoto, H [1 ]
Numata, Y [1 ]
Takemoto, H [1 ]
机构
[1] Shionogi & Co Ltd, Discovery Res Labs, Fukushima Ku, Osaka 5530002, Japan
关键词
rare earth cryptate; homogeneous time-resolved fluorescence; heparanase; heparan sulfate; melanoma cells; endoglycosidase assay;
D O I
10.1016/j.jpba.2006.01.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Degradation of heparan sulfate proteoglycan by heparanase is an important process in tissue invasion by malignant tumor cells and inflammatory cells. Several heparanase assays have been reported previously, but all of them are cumbersome and time-consuming for separating degradative products from uncleaved substrates and detecting these products. This paper describes the development of a simple and rapid assay for heparanase activity using homogeneous time-resolved fluorescence based on non-radiative energy transfer. In this assay, heparan sulfate proteoglycan labeled with biotin and europium cryptate (fluorescence donor) was used as a substrate for heparanase. Degradation of the substrate by incubation with murine melanoma cell extract was detected by measuring the time-resolved fluorescence after addition of XL665 (cross-linked allophycocyanin, fluorescence acceptor)-labeled streptavidin. As heparanase activity can be simply measured by successive addition of substrate, enzyme and detection reagent onto one assay plate, our heparanase assay allows rapid processing of large numbers of samples. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:912 / 917
页数:6
相关论文
共 50 条
  • [31] Measuring human beta-secretase (BACE1) activity using homogeneous time-resolved fluorescence
    Kennedy, M
    Song, LX
    Lee, J
    Zhang, LL
    Wong, G
    Wang, LY
    Parker, E
    Beyer, B
    Wang, WY
    NEUROBIOLOGY OF AGING, 2002, 23 (01) : S184 - S184
  • [32] Time-resolved fluorometric assay for leukocyte adhesion using a fluorescence enhancing ligand
    Saarinen, K
    Kivistö, K
    Blomberg, K
    Punnonen, K
    Leino, L
    JOURNAL OF IMMUNOLOGICAL METHODS, 2000, 236 (1-2) : 19 - 26
  • [33] Tyrosine kinase assays adapted to homogeneous time-resolved fluorescence
    Kolb, AJ
    Kaplita, PV
    Hayes, DJ
    Park, YW
    Pernell, C
    Major, JS
    Mathis, G
    DRUG DISCOVERY TODAY, 1998, 3 (07) : 333 - 342
  • [34] Homogeneous time resolved fluorescence assay to measure histamine release
    Claret, EJ
    Ouled-Diaf, J
    Seguin, P
    COMBINATORIAL CHEMISTRY & HIGH THROUGHPUT SCREENING, 2003, 6 (08) : 789 - 794
  • [35] A separation-free assay for the detection of mutations: Combination of homogeneous time-resolved fluorescence and mini sequencing
    Lopez-Crapez, E
    Bazin, H
    Chevalier, J
    Trinquet, E
    Grenier, J
    Mathis, G
    HUMAN MUTATION, 2005, 25 (05) : 468 - 475
  • [36] A new strategy based on aptasensor to time-resolved fluorescence assay for adenosine deaminase activity
    Zhang, Kai
    Xie, Minhao
    Zhou, Bin
    Hua, Yurong
    Yan, Zihe
    Liu, Haiyan
    Guo, Li-ning
    Wu, Bing
    Huang, Biao
    BIOSENSORS & BIOELECTRONICS, 2013, 41 : 123 - 128
  • [37] Zeptomole detection sensitivity of prostate-specific antigen in a rapid microtitre plate assay using time-resolved fluorescence
    Härmä, H
    Soukka, T
    Lönnberg, S
    Paukkunen, J
    Tarkkinen, P
    Lövgren, T
    LUMINESCENCE, 2000, 15 (06) : 351 - 355
  • [38] Quantitative and rapid detection of microcystin-LR using time-resolved fluorescence immunochromatographic assay based on europium nanospheres
    Zhang, Yi
    Ding, Xin-Liang
    Guo, Ming-Ming
    Han, Ting-Ting
    Huang, Zi-Jian
    Shang, Hong-Tao
    Huang, Biao
    ANALYTICAL METHODS, 2017, 9 (45) : 6430 - 6434
  • [39] Time-resolved fluorometric assay for natural killer activity using target cells labelled with a fluorescence enhancing ligand
    Blomberg, K
    Hautala, R
    Lovgren, J
    Mukkala, VM
    Lindqvist, C
    Akerman, K
    JOURNAL OF IMMUNOLOGICAL METHODS, 1996, 193 (02) : 199 - 206
  • [40] Simple and rapid monitoring of doxorubicin using streptavidin-modified microparticle-based time-resolved fluorescence immunoassay
    Liang, Junyu
    Zhang, Zhigao
    Zhao, Hui
    Wan, Shanhe
    Zhai, Xiangming
    Zhou, Jianwei
    Liang, Rongliang
    Deng, Qiaoting
    Wu, Yingsong
    Lin, Guanfeng
    RSC ADVANCES, 2018, 8 (28) : 15621 - 15631