Influence of rigidity of retainers on dynamic behavior of implant-supported removable partial dentures

被引:6
|
作者
Nogawa, Toshifumi [1 ]
Saito, Masayasu [2 ]
Murashima, Naomichi [3 ]
Takayama, Yoshiyuki [4 ]
Yokoyama, Atsuro [2 ]
机构
[1] Hokkaido Univ Hosp, Prevent Dent, Sapporo, Hokkaido, Japan
[2] Hokkaido Univ, Div Oral Funct Sci, Oral Funct Prosthodont, Facil Dent Med, Sapporo, Hokkaido, Japan
[3] Hokkaido Univ, Grad Sch Dent Med, Div Oral Funct Sci, Oral Funct Prosthodont, Sapporo, Hokkaido, Japan
[4] Hokkaido Univ Hosp, Oral Rehabil, Sapporo, Hokkaido, Japan
关键词
Implant-supported partial dentures; Removable partial dentures; Direct retainers; Dynamic behavior; Rigidity of connection; FINITE-ELEMENT-ANALYSIS; MULTICENTER PROSPECTIVE EVALUATION; KENNEDY CLASS-I; DISTAL-EXTENSION; STRESS-DISTRIBUTION; ABUTMENT TOOTH; DENTAL PROSTHESIS; LOADING VARIABLES; DISPLACEMENT; PLACEMENT;
D O I
10.1186/s40729-020-00260-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background Implant-supported removable partial dentures (ISRPDs) are an effective treatment for partially edentulous patients. ISRPDs improve patients' satisfaction and oral function to a greater extent than RPDs by improving denture stability and enhancing support. However, the effect of a type of direct retainer on displacement of the abutment teeth and dentures in ISRPDs remains unclear. Therefore, we made a resin mandibular model of unilateral mandibular distal-extension partial edentulism for mechanical simulation and compared the dynamic behavior of the abutment teeth and the denture base among different tooth-borne retainers with various rigidities for RPDs and ISRPDs. Methods A resin mandibular model for mechanical simulation that had unilateral mandibular distal-extension edentulism and was missing the first molar, second molar, first premolar, and second premolar, and a denture fabricated from the patient's computed tomography images were used. Three types of direct retainers with different connecting rigidities were evaluated. The vertical displacement of the denture base and buccal and lingual sides and the mesial displacement of the abutment teeth were measured. Results Regardless of the rigidity of the direct retainers and loading positions, the displacement of the denture bases in the ISRPDs was significantly smaller than that in the RPDs (P < 0.001). There was no significant difference in vertical displacement of the denture bases among direct retainers with various connecting rigidities in the ISRPDs. Conversely, horizontal displacement of the abutment teeth in both the RPDs and ISRPDs tended to be larger with the cone crown telescope, which has high rigidity, than with the cast cingulum rest and wire clasp, which have much lower rigidities. Conclusion Our results suggested that cast cingulum rest and wire clasps as direct retainers are appropriate ISRPDs to minimize denture movement and suppress displacement of the remaining teeth in patients with unilateral mandibular distal-extension partial edentulism.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Effect of bar designs on peri implant tissues health in implant-supported removable prostheses: a systematic review
    Omeish, Nadine
    Bessou, Laure
    Carra, Maria-Clotilde
    Tavernier, Bruno
    Porporatti, Andre Luis
    BMC ORAL HEALTH, 2024, 24 (01)
  • [42] Retention and stress distribution in distal extension removable partial dentures with and without implant association
    Silveira Rodrigues, Renata Cristina
    Lapria Faria, Adriana Claudia
    Macedo, Ana Paula
    Chiarello de Mattos, Maria da Gloria
    Ribeiro, Ricardo Faria
    JOURNAL OF PROSTHODONTIC RESEARCH, 2013, 57 (01) : 24 - 29
  • [43] Identification of risk factors for fracture of veneering materials and screw loosening of implant-supported fixed partial dentures in partially edentulous cases
    Noda, K.
    Arakawa, H.
    Maekawa, K.
    Hara, E. S.
    Yamazaki, S.
    Kimura-Ono, A.
    Sonoyama, W.
    Minakuchi, H.
    Matsuka, Y.
    Kuboki, T.
    JOURNAL OF ORAL REHABILITATION, 2013, 40 (03) : 214 - 220
  • [44] Technical complications of implant-supported fixed partial dentures in partially edentulous cases after an average observation period of 5 years
    Kreissl, Marion E.
    Gerds, Thomas
    Muche, Robert
    Heydecke, Guido
    Strub, Joerg R.
    CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (06) : 720 - 726
  • [45] Influence of Loading and Use of Occlusal Splint in Implant-Supported Fixed Prostheses
    Teixeira, Fabiola Marchezini
    de Assis Claro, Cristiane Aparecida
    Claro Neves, Ana Christina
    Rode, Sigmar de Mello
    da Silva-Concilio, Lais Regiane
    JOURNAL OF CRANIOFACIAL SURGERY, 2012, 23 (05) : E477 - E480
  • [46] Patient-reported outcomes of maxillary implant-supported overdentures compared with conventional dentures
    Zembic, Anja
    Wismeijer, Daniel
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (04) : 441 - 450
  • [47] Influence of the frameworks of implant-supported prostheses and implant connections on stress distribution
    Tonin, Bruna Santos Honorio
    Peixoto, Raniel Fernandes
    Fu, Jing
    de Mattos, Maria da Gloria Chiarello
    Macedo, Ana Paula
    DENTAL AND MEDICAL PROBLEMS, 2023, 60 (04) : 551 - 557
  • [48] Clinical Outcomes of Posterior Implants with Surveyed Crowns for Implant-Assisted Removable Partial Dentures: A Retrospective Study
    Jung, Tae-Wook
    Yi, Yang-Jin
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (01) : 53 - 61
  • [49] Implant-Assisted Removable Partial Dentures in Mandibular Kennedy Class I Patients: The Impact of Implant Positioning
    Messias, Ana
    Nicolau, Pedro
    Guerra, Fernando
    Amaro, Ana
    Roseiro, Luis
    Augusta Neto, Maria
    XV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING - MEDICON 2019, 2020, 76 : 1424 - 1430
  • [50] Periodontal ligament influence on the stress distribution in a removable partial denture supported by implant: a finite element analysis
    Archangelo, Carlos Marcelo
    Rocha, Eduardo Passos
    Pereira, Joao Antonio
    Martin Junior, Manoel
    Anchieta, Rodolfo Bruniera
    Freitas Junior, Amilcar Chagas
    JOURNAL OF APPLIED ORAL SCIENCE, 2012, 20 (03) : 362 - 368