Influence of rigidity of retainers on dynamic behavior of implant-supported removable partial dentures

被引:6
|
作者
Nogawa, Toshifumi [1 ]
Saito, Masayasu [2 ]
Murashima, Naomichi [3 ]
Takayama, Yoshiyuki [4 ]
Yokoyama, Atsuro [2 ]
机构
[1] Hokkaido Univ Hosp, Prevent Dent, Sapporo, Hokkaido, Japan
[2] Hokkaido Univ, Div Oral Funct Sci, Oral Funct Prosthodont, Facil Dent Med, Sapporo, Hokkaido, Japan
[3] Hokkaido Univ, Grad Sch Dent Med, Div Oral Funct Sci, Oral Funct Prosthodont, Sapporo, Hokkaido, Japan
[4] Hokkaido Univ Hosp, Oral Rehabil, Sapporo, Hokkaido, Japan
关键词
Implant-supported partial dentures; Removable partial dentures; Direct retainers; Dynamic behavior; Rigidity of connection; FINITE-ELEMENT-ANALYSIS; MULTICENTER PROSPECTIVE EVALUATION; KENNEDY CLASS-I; DISTAL-EXTENSION; STRESS-DISTRIBUTION; ABUTMENT TOOTH; DENTAL PROSTHESIS; LOADING VARIABLES; DISPLACEMENT; PLACEMENT;
D O I
10.1186/s40729-020-00260-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background Implant-supported removable partial dentures (ISRPDs) are an effective treatment for partially edentulous patients. ISRPDs improve patients' satisfaction and oral function to a greater extent than RPDs by improving denture stability and enhancing support. However, the effect of a type of direct retainer on displacement of the abutment teeth and dentures in ISRPDs remains unclear. Therefore, we made a resin mandibular model of unilateral mandibular distal-extension partial edentulism for mechanical simulation and compared the dynamic behavior of the abutment teeth and the denture base among different tooth-borne retainers with various rigidities for RPDs and ISRPDs. Methods A resin mandibular model for mechanical simulation that had unilateral mandibular distal-extension edentulism and was missing the first molar, second molar, first premolar, and second premolar, and a denture fabricated from the patient's computed tomography images were used. Three types of direct retainers with different connecting rigidities were evaluated. The vertical displacement of the denture base and buccal and lingual sides and the mesial displacement of the abutment teeth were measured. Results Regardless of the rigidity of the direct retainers and loading positions, the displacement of the denture bases in the ISRPDs was significantly smaller than that in the RPDs (P < 0.001). There was no significant difference in vertical displacement of the denture bases among direct retainers with various connecting rigidities in the ISRPDs. Conversely, horizontal displacement of the abutment teeth in both the RPDs and ISRPDs tended to be larger with the cone crown telescope, which has high rigidity, than with the cast cingulum rest and wire clasp, which have much lower rigidities. Conclusion Our results suggested that cast cingulum rest and wire clasps as direct retainers are appropriate ISRPDs to minimize denture movement and suppress displacement of the remaining teeth in patients with unilateral mandibular distal-extension partial edentulism.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Retrospective investigation of the remaining teeth status of patients with implant-supported fixed partial dentures in unilateral free-end edentulism
    Yamazaki, Seiya
    Arakawa, Hikaru
    Maekawa, Kenji
    Hara, Emilio Satoshi
    Noda, Kinji
    Minakuchi, Hajime
    Sonoyama, Wataru
    Matsuka, Yoshizo
    Kuboki, Takuo
    JOURNAL OF PROSTHODONTIC RESEARCH, 2013, 57 (04) : 262 - 267
  • [32] Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
    Suedam, Valdey
    Moretti Neto, Rafael Tobias
    Capello Sousa, Edson Antonio
    Rubo, Jose Henrique
    JOURNAL OF APPLIED ORAL SCIENCE, 2016, 24 (02) : 114 - 120
  • [33] Implant-assisted removable partial dentures: Part II. a systematic review of the effects of implant position on the biomechanical behavior
    Kuroshima, Shinichiro
    Sasaki, Muneteru
    Al-Omari, Farah A.
    Uto, Yusuke
    Ohta, Yoshikazu
    Uchida, Yusuke
    Sawase, Takashi
    JOURNAL OF PROSTHODONTIC RESEARCH, 2024, 68 (01) : 40 - 49
  • [34] Survival time analysis of remaining teeth following replacement of unilateral free-end missing teeth: A comparison between fixed implant-supported prostheses and removable partial dentures
    Tsujioka, Yoshitaka
    Mameno, Tomoaki
    Akema, Suzuna
    Hasegawa, Daisuke
    Okada, Yoshie
    Seto, Eri
    Gonda, Tomoya
    Yang, Tsung-Chieh
    Wada, Masahiro
    Ikebe, Kazunori
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (05) : 526 - 533
  • [35] The influence of bone quality on the biomechanical behavior of full-arch implant-supported fixed prostheses
    Faverani, Leonardo Perez
    Ricardo Barao, Valentim Adelino
    Ramalho-Ferreira, Gabriel
    Delben, Juliana Aparecida
    Ferreira, Mayara Barbosa
    Garcia Junior, Idelmo Rangel
    Assuncao, Wirley Goncalves
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 37 : 164 - 170
  • [36] In vitro study of the effect of implant position and attachment type on stress distribution of implant-assisted removable partial dentures
    Naing, Sai Tun
    Kanazawa, Manabu
    Hada, Tamaki
    Iwaki, Maiko
    Komagamine, Yuriko
    Miyayasu, Anna
    Uehara, Yoko
    Minakuchi, Shunsuke
    JOURNAL OF DENTAL SCIENCES, 2022, 17 (04) : 1697 - 1703
  • [37] Transition from a failing dentition to a removable implant-supported prosthesis: A staged approach
    Cordaro, Luca
    Torsello, Ferruccio
    Ribeiro, Carlos Accorsi
    QUINTESSENCE INTERNATIONAL, 2010, 41 (05): : 371 - 378
  • [38] Implant-Connected Versus Tooth-Connected Implant-Supported Partial Dentures: 2-Year Clinical and Radiographic Comparative Evaluation
    Mostafa, Tamer Mohamed Nasr
    El-Sheikh, Mohamed M.
    El-Fattah, Fade El-Said Abd
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2015, 35 (03) : 335 - 343
  • [39] Impact of implant location on load distribution of implant-assisted removable partial dentures: a review of in vitro model and finite-element analysis studies
    Ichikawa, Hiromi
    Yoda, Nobuhiro
    Ogawa, Toru
    Iwamoto, Maya
    Kawata, Tetsuo
    Egusa, Hiroshi
    Sasaki, Keiichi
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2023, 9 (01)
  • [40] Biomechanical behavior of titanium, cobalt-chromium, zirconia, and PEEK frameworks in implant-supported prostheses: a dynamic finite element analysis
    Hazir, Dilara Sahin
    Yanik, Irem Sozen
    Guncu, M. Baris
    Canay, R. Senay
    BMC ORAL HEALTH, 2025, 25 (01):