Influence of rigidity of retainers on dynamic behavior of implant-supported removable partial dentures

被引:6
|
作者
Nogawa, Toshifumi [1 ]
Saito, Masayasu [2 ]
Murashima, Naomichi [3 ]
Takayama, Yoshiyuki [4 ]
Yokoyama, Atsuro [2 ]
机构
[1] Hokkaido Univ Hosp, Prevent Dent, Sapporo, Hokkaido, Japan
[2] Hokkaido Univ, Div Oral Funct Sci, Oral Funct Prosthodont, Facil Dent Med, Sapporo, Hokkaido, Japan
[3] Hokkaido Univ, Grad Sch Dent Med, Div Oral Funct Sci, Oral Funct Prosthodont, Sapporo, Hokkaido, Japan
[4] Hokkaido Univ Hosp, Oral Rehabil, Sapporo, Hokkaido, Japan
关键词
Implant-supported partial dentures; Removable partial dentures; Direct retainers; Dynamic behavior; Rigidity of connection; FINITE-ELEMENT-ANALYSIS; MULTICENTER PROSPECTIVE EVALUATION; KENNEDY CLASS-I; DISTAL-EXTENSION; STRESS-DISTRIBUTION; ABUTMENT TOOTH; DENTAL PROSTHESIS; LOADING VARIABLES; DISPLACEMENT; PLACEMENT;
D O I
10.1186/s40729-020-00260-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background Implant-supported removable partial dentures (ISRPDs) are an effective treatment for partially edentulous patients. ISRPDs improve patients' satisfaction and oral function to a greater extent than RPDs by improving denture stability and enhancing support. However, the effect of a type of direct retainer on displacement of the abutment teeth and dentures in ISRPDs remains unclear. Therefore, we made a resin mandibular model of unilateral mandibular distal-extension partial edentulism for mechanical simulation and compared the dynamic behavior of the abutment teeth and the denture base among different tooth-borne retainers with various rigidities for RPDs and ISRPDs. Methods A resin mandibular model for mechanical simulation that had unilateral mandibular distal-extension edentulism and was missing the first molar, second molar, first premolar, and second premolar, and a denture fabricated from the patient's computed tomography images were used. Three types of direct retainers with different connecting rigidities were evaluated. The vertical displacement of the denture base and buccal and lingual sides and the mesial displacement of the abutment teeth were measured. Results Regardless of the rigidity of the direct retainers and loading positions, the displacement of the denture bases in the ISRPDs was significantly smaller than that in the RPDs (P < 0.001). There was no significant difference in vertical displacement of the denture bases among direct retainers with various connecting rigidities in the ISRPDs. Conversely, horizontal displacement of the abutment teeth in both the RPDs and ISRPDs tended to be larger with the cone crown telescope, which has high rigidity, than with the cast cingulum rest and wire clasp, which have much lower rigidities. Conclusion Our results suggested that cast cingulum rest and wire clasps as direct retainers are appropriate ISRPDs to minimize denture movement and suppress displacement of the remaining teeth in patients with unilateral mandibular distal-extension partial edentulism.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] A retrospective comparative ten-year study of cumulative survival rates of remaining teeth in large edentulism treated with implant-supported fixed partial dentures or removable partial dentures
    Yamazaki, Seiya
    Arakawa, Hikaru
    Maekawa, Kenji
    Hara, Emilio Satoshi
    Noda, Kinji
    Minakuchi, Hajime
    Sonoyama, Wataru
    Matsuka, Yoshizo
    Kuboki, Takuo
    JOURNAL OF PROSTHODONTIC RESEARCH, 2013, 57 (03) : 156 - 161
  • [22] Comparison of the prognosis of the remaining teeth between implant-supported fixed prostheses and removable partial dentures in partially edentulous patients: A retrospective study
    Yamada, Ryo
    Nogawa, Toshifumi
    Takayama, Yoshiyuki
    Iwata, Kai
    Saito, Masayasu
    Yokoyama, Atsuro
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2022, 24 (01) : 83 - 93
  • [23] Influence of connection type on the biomechanical behavior of distal extension mandibular removable partial dentures supported by implants and natural teeth
    Xiao, Wei
    Li, Zhiyong
    Shen, Shiqian
    Chen, Shaowu
    Chen, Sulin
    Wang, Jiawei
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2016, 19 (03) : 240 - 247
  • [24] Retrospective clinical evaluation of implant-assisted removable partial dentures combined with implant surveyed prostheses
    Oh, You-Kyoung
    Bae, Eun-Bin
    Huh, Jung-Bo
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (01) : 76 - 82
  • [25] Survival and complication rates of implant-supported fixed partial dentures with cantilevers: a systematic review
    Zurdo, Jose
    Romao, Cristina
    Wennstrom, Jan L.
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 : 59 - 66
  • [26] Influence of location of osseointegrated implant on stress distribution in implant supported longitudinal removable partial dentures: 3-dimensional finite element analysis
    Liu, Yang
    Zhang, Yi-Nan
    Sasaki, Keiichi
    Chen, Xiao-Dong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2019, 12 (08): : 10399 - 10410
  • [27] Transition from Failing Dentition to Full-Arch Fixed Implant-Supported Prosthesis with a Staged Approach Using Removable Partial Dentures: A Case Series
    Gonzalez Cortes, Arthur Rodriguez
    Cortes, Djalma Nogueira
    No-Cortes, Juliana
    Arita, Emiko Saito
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (04): : 328 - 332
  • [28] Clinical Outcomes of Implant-Assisted Removable Partial Dentures According to Implant Strategic Position
    Yi, Yuseung
    Heo, Seong-Joo
    Koak, Jai-Young
    Kim, Seong-Kyun
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (05): : 401 - 410
  • [29] Load distribution on abutment tooth, implant and residual ridge with distal-extension implant-supported removable partial denture
    Matsudate, Yoshiki
    Yoda, Nobuhiro
    Nanba, Masahide
    Ogawa, Toru
    Sasaki, Keiichi
    JOURNAL OF PROSTHODONTIC RESEARCH, 2016, 60 (04) : 282 - 288
  • [30] Biomechanical behavior of the dental implant macrodesign in mandibular implant-supported overdentures
    Okkan, G. S.
    Kucukkurt, S.
    Terzioglu, H.
    Mollaoglu, N.
    JOURNAL OF OSSEOINTEGRATION, 2021, 13 (04) : 234 - 241