Microwave ablation: Results with a 2.45-GHz applicator in ex vivo bovine and in vivo porcine liver

被引:148
作者
Hines-Peralta, AU
Pirani, N
Clegg, P
Cronin, N
Ryan, TP
Liu, ZJ
Goldberg, SN
机构
[1] Harvard Univ, Sch Med, Dept Radiol, Beth Israel Deaconess Med Ctr, Boston, MA 02215 USA
[2] Univ Bath, Dept Phys, Bath BA2 7AY, Avon, England
[3] Microsulis Amer, Waltham, MA USA
关键词
D O I
10.1148/radiol.2383050262
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To characterize the relationship between applied power and treatment duration in their effect on extent or coagulation produced with a 2.45-GHz microwave applicator in both an ex vivo and a perfused in vivo liver model. Materials and Methods: All experimentation was approved by the Institnte of Animal Care and Use Committee. Multiple tissue ablations were performed in ex vivo bovine liver (120 ablations) and in vivo porcine liver, (45 ablations) with a 5.7-mm-diameter 2.45-GHz microwave applicator. The applied power was varied from 50 to 150 W (in 25-W increments ex vivo and 50-W increments in vivo), while treatment. duration varied from 2 to 20 minutes (in eight time increments for ex vivo and five for in vivo liver). Three-dimensional contour maps of the resultant short- and long-axis coagulation diameters were constructed to identify the optimal parameters to achieve maximum coagulation in both ex vivo and in vivo models. Multivariate analysis was performed to characterize the relationship between applied power and treatment duration. Results: Power and treatment duration were both associated with coagulation diameter in a si-rnoidal fashion (ex vivo, R 0.78; in vivo, R-2 = 0.74). For ex vivo liver, the maximum short-axis coagulation diameter (7.6 cm +/- 0.2 [standard deviation] by 12.3 cm +/- 0.8) was achieved at greatest power (150 W) and duration (20 minutes). In vivo studies revealed a sigmoidal relationship between duration and coagulation size, with a relative plateau in coagolation size achieved within 8 minutes duration at all power levels. After 8 minutes of treatment at. 150 W, the mean short-axis coagulation diameter for in vivo liver was 5.7 cm +/- 0.2 by 6.5 cm +/- 1.7, which was significantly larger than the corresponding result for ex vivo liver (P <.05). Conclusion: Large zones of ablation can he achieved with the 2.45-GHz microwave applicator used by the authors. For higher-power ablations, larger zones of coagulation were achieved for in vivo liver than for ex vivo liver with short energy applications, a finding previously not seen with other ablation devices, to the anthors' knowledge.
引用
收藏
页码:94 / 102
页数:9
相关论文
共 43 条
  • [1] Radiofrequency ablation of metastatic lesions in adrenocortical cancer
    Abraham, J
    Fojo, T
    Wood, BJ
    [J]. ANNALS OF INTERNAL MEDICINE, 2000, 133 (04) : 312 - 313
  • [2] Aramaki M, 2004, HEPATO-GASTROENTEROL, V51, P1784
  • [3] Radiofrequency ablation of unresectable primary and metastatic hepatic malignancies - Results in 123 patients
    Curley, SA
    Izzo, F
    Delrio, P
    Ellis, LM
    Granchi, J
    Vallone, P
    Fiore, F
    Pignata, S
    Daniele, B
    Cremona, F
    [J]. ANNALS OF SURGERY, 1999, 230 (01) : 1 - 8
  • [4] Radiofrequency ablation of 100 hepatic metastases with a mean follow-up of more than 1 year
    de Baere, T
    Elias, D
    Dromain, C
    El Din, MG
    Kuoch, V
    Ducreux, M
    Boige, V
    Lassau, N
    Marteau, V
    Lasser, P
    Roche, A
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (06) : 1619 - 1625
  • [5] Transperineal radiofrequency interstitial tumor ablation of the prostate: Correlation of magnetic resonance imaging with histopathologic examination
    Djavan, B
    Zlotta, AR
    Susani, M
    Heinz, G
    Shariat, S
    Silverman, DE
    Schulman, CC
    Marberger, M
    [J]. UROLOGY, 1997, 50 (06) : 986 - 992
  • [6] Percutaneous sonographically guided microwave coagulation therapy for hepatocellular carcinoma: Results in 234 patients
    Dong, BW
    Liang, P
    Yu, XL
    Su, L
    Yu, DJ
    Cheng, ZG
    Zhang, J
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (06) : 1547 - 1555
  • [7] Image-guided radiofrequency tumor ablation: Challenges and opportunities - Part II
    Dupuy, DE
    Goldberg, SN
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (10) : 1135 - 1148
  • [8] Radiofrequency ablation of regional recurrence from well-differentiated thyroid malignancy
    Dupuy, DE
    Monchik, JM
    Decrea, C
    Pisharodi, L
    [J]. SURGERY, 2001, 130 (06) : 971 - 977
  • [9] Dupuy DE, 1998, RADIOLOGY, V209P, P389
  • [10] Molecular dynamics simulations of microwave heating of water
    English, NJ
    MacElroy, JMD
    [J]. JOURNAL OF CHEMICAL PHYSICS, 2003, 118 (04) : 1589 - 1592