How does scanner choice and 3D model resolution affect data accuracy?

被引:11
作者
Balolia, Katharine L. [1 ]
Massey, Jason S. [2 ,3 ]
机构
[1] Australian Natl Univ, Sch Archaeol & Anthropol, Canberra, ACT, Australia
[2] Univ Minnesota, Sch Med, Dept Integrat Biol & Physiol, Minneapolis, MN 55455 USA
[3] Monash Univ, Dept Anat & Dev Biol, Melbourne, Vic, Australia
关键词
Accuracy; CT scanning; laser scanning; resolution; virtual measurements; white light scanning;
D O I
10.1111/joa.13343
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Researchers using digital methods often collect data from 3D models at different resolutions, obtained using different scanning techniques. Although previous research has sought to understand whether scanning method and model resolution affect data accuracy, no study has systematically evaluated the sources of error associated with scanning method, data acquisition method and model resolution with the aim of providing practical recommendations about the model resolution required to yield sufficiently accurate data for specimens of given sizes. In this study, using data taken from primate specimens of three broad size categories, we test whether 3D models obtained using five different scanners (Breuckmann SmartSCAN, DAVID/HP 3D Pro S3, NextEngine 2020i, Creaform Go!Scan 20 and microCT/clinicalCT) yield accurate measurements. We assess whether caliper measurements can be used alongside measurements collected from 3D surface models, whether scanning resolution affects measurement accuracy, and how scan resolution, estimated using each scanner's proprietary software, compares to model resolution measured in a standardized way. Each scanner produces 3D models that yield accurate measurements for each size category, however, combining caliper data with those taken from digital models can be problematic. Our results indicate that the accuracy of measurements taken from 3D models depends on both object size and model resolution. Based on our findings, we recommend that small specimens should be scanned at <0.3 mm, medium specimens at 0.3-0.7 mm, and large specimens at 0.3-0.5 mm resolutions if data taken from 3D surface models are to be combined with caliper datasets. We further show, for the first time, that discrepancies in estimated final model resolution are frequently observed across software packages. We therefore recommend that researchers ensure that final model resolutions are adequate based on specimen size and are independently verified using a software package other than the scanner's proprietary software. Finally, we consider the implications of the findings that measurements obtained from surface models are variably consistent with those obtained using calipers.
引用
收藏
页码:679 / 692
页数:14
相关论文
共 17 条
[1]   Three-dimensional procrustes analysis of modern human craniofacial form [J].
Badawi-Fayad, Jackie ;
Cabanis, Emmanuel-Alain .
ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2007, 290 (03) :268-276
[2]   Effects of cropping, smoothing, triangle count, and mesh resolution on 6 dental topographic metrics [J].
Berthaume, Michael A. ;
Winchester, Julia ;
Kupczik, Kornelius .
PLOS ONE, 2019, 14 (05)
[3]   Open data and digital morphology [J].
Davies, Thomas G. ;
Rahman, Imran A. ;
Lautenschlager, Stephan ;
Cunningham, John A. ;
Asher, Robert J. ;
Barrett, Paul M. ;
Bates, Karl T. ;
Bengtson, Stefan ;
Benson, Roger B. J. ;
Boyer, Doug M. ;
Braga, Jose ;
Bright, Jen A. ;
Claessens, Leon P. A. M. ;
Cox, Philip G. ;
Dong, Xi-Ping ;
Evans, Alistair R. ;
Falkingham, Peter L. ;
Friedman, Matt ;
Garwood, Russell J. ;
Goswami, Anjali ;
Hutchinson, John R. ;
Jeffery, Nathan S. ;
Johanson, Zerina ;
Lebrun, Renaud ;
Martinez-Perez, Carlos ;
Marugan-Lobon, Jesus ;
O'Higgins, Paul M. ;
Metscher, Brian ;
Orliac, Maeva ;
Rowe, Timothy B. ;
Rucklin, Martin ;
Sanchez-Villagra, Marcelo R. ;
Shubin, Neil H. ;
Smith, Selena Y. ;
Starck, J. Matthias ;
Stringer, Chris ;
Summers, Adam P. ;
Sutton, Mark D. ;
Walsh, Stig A. ;
Weisbecker, Vera ;
Witmer, Lawrence M. ;
Wroe, Stephen ;
Yin, Zongjun ;
Rayfield, Emily J. ;
Donoghue, Philip C. J. .
PROCEEDINGS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 2017, 284 (1852)
[4]   Measurement error in μCT-based three-dimensional geometric morphometrics introduced by surface generation and landmark data acquisition [J].
Engelkes, Karolin ;
Helfsgott, Jennice ;
Hammel, Joerg U. ;
Buesse, Sebastian ;
Kleinteich, Thomas ;
Beerlink, Andre ;
Gorb, Stanislav N. ;
Haas, Alexander .
JOURNAL OF ANATOMY, 2019, 235 (02) :357-378
[5]   Evaluation of anthropometric accuracy and reliability using different three-dimensional scanning systems [J].
Fourie, Zacharias ;
Damstra, Janalt ;
Gerrits, Peter O. ;
Ren, Yijin .
FORENSIC SCIENCE INTERNATIONAL, 2011, 207 (1-3) :127-134
[6]   Sharing is caring? Measurement error and the issues arising from combining 3D morphometric datasets [J].
Fruciano, Carmelo ;
Celik, Melina A. ;
Butler, Kaylene ;
Dooley, Tom ;
Weisbecker, Vera ;
Phillips, Matthew J. .
ECOLOGY AND EVOLUTION, 2017, 7 (17) :7034-7046
[7]   Low resolution scans can provide a sufficiently accurate, cost- and time-effective alternative to high resolution scans for 3D shape analyses [J].
Marcy, Ariel E. ;
Fruciano, Carmelo ;
Phillips, Matthew J. ;
Mardon, Karine ;
Weisbecker, Vera .
PEERJ, 2018, 6
[8]  
Mathys Aurore, 2013, 2013 Digital Heritage International Congress (DigitalHeritage). Federating the 19th Int'I VSMM, 10th Eurographics GCH, & 2nd UNESCO Memory of the World Conferences, plus special sessions from CAA, Arqueologico 2.0, Space2Place, ICOMOS ICIP & CIPA, EU projects, et al. Proceedings, P201
[9]   Estimating Biological Characteristics With Virtual Laser Data [J].
Mullins, Ryan A. ;
Albanese, John .
JOURNAL OF FORENSIC SCIENCES, 2018, 63 (03) :815-823
[10]   Error in geometric morphometric data collection: Combining data from multiple sources [J].
Robinson, Chris ;
Terhune, Claire E. .
AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2017, 164 (01) :62-75