Priori mask guided image reconstruction (p-MGIR) for ultra-low dose cone-beam computed tomography

被引:6
|
作者
Park, Justin C. [1 ]
Zhang, Hao [2 ]
Chen, Yunmei [2 ]
Fan, Qiyong [3 ]
Kahler, Darren L. [1 ]
Liu, Chihray [1 ]
Lu, Bo [1 ]
机构
[1] Univ Florida, Dept Radiat Oncol, Gainesville, FL 32610 USA
[2] Univ Florida, Dept Math, Gainesville, FL 32611 USA
[3] Univ Nebraska Med Ctr, Dept Radiat Oncol, Omaha, NE 68105 USA
关键词
p-MGIR; 3DCBCT; iterative image reconstruction; compressed sensing; on-line IGRT; COMPRESSED SENSING ABOCS; CT RECONSTRUCTION; CANCER-RISKS; GPU; PROJECTION; ALGORITHM; NOISE;
D O I
10.1088/0031-9155/60/21/8505
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recently, the compressed sensing (CS) based iterative reconstruction method has received attention because of its ability to reconstruct cone beam computed tomography (CBCT) images with good quality using sparsely sampled or noisy projections, thus enabling dose reduction. However, some challenges remain. In particular, there is always a tradeoff between image resolution and noise/streak artifact reduction based on the amount of regularization weighting that is applied uniformly across the CBCT volume. The purpose of this study is to develop a novel low-dose CBCT reconstruction algorithm framework called priori mask guided image reconstruction (p-MGIR) that allows reconstruction of high-quality low-dose CBCT images while preserving the image resolution. In p-MGIR, the unknown CBCT volume was mathematically modeled as a combination of two regions: (1) where anatomical structures are complex, and (2) where intensities are relatively uniform. The priori mask, which is the key concept of the p-MGIR algorithm, was defined as the matrix that distinguishes between the two separate CBCT regions where the resolution needs to be preserved and where streak or noise needs to be suppressed. We then alternately updated each part of image by solving two sub-minimization problems iteratively, where one minimization was focused on preserving the edge information of the first part while the other concentrated on the removal of noise/artifacts from the latter part. To evaluate the performance of the p-MGIR algorithm, a numerical head-and-neck phantom, a Catphan 600 physical phantom, and a clinical head-and-neck cancer case were used for analysis. The results were compared with the standard Feldkamp-Davis-Kress as well as conventional CS-based algorithms. Examination of the p-MGIR algorithm showed that high-quality low-dose CBCT images can be reconstructed without compromising the image resolution. For both phantom and the patient cases, the p-MGIR is able to achieve a clinically-reasonable image with 60 projections. Therefore, a clinically-viable, high-resolution head-and-neck CBCT image can be obtained while cutting the dose by 83%. Moreover, the image quality obtained using p-MGIR is better than the quality obtained using other algorithms. In this work, we propose a novel low-dose CBCT reconstruction algorithm called p-MGIR. It can be potentially used as a CBCT reconstruction algorithm with low dose scan requests
引用
收藏
页码:8505 / 8524
页数:20
相关论文
共 50 条
  • [41] A Compressed-Sensing Based Blind Deconvolution Method for Image Deblurring in Dental Cone-Beam Computed Tomography
    Kim, K. S.
    Kang, S. Y.
    Park, C. K.
    Kim, G. A.
    Park, S. Y.
    Cho, Hyosung
    Seo, C. W.
    Lee, D. Y.
    Lim, H. W.
    Lee, H. W.
    Park, J. E.
    Woo, T. H.
    Oh, J. E.
    JOURNAL OF DIGITAL IMAGING, 2019, 32 (03) : 478 - 488
  • [42] A Compressed-Sensing Based Blind Deconvolution Method for Image Deblurring in Dental Cone-Beam Computed Tomography
    K. S. Kim
    S. Y. Kang
    C. K. Park
    G. A. Kim
    S. Y. Park
    Hyosung Cho
    C. W. Seo
    D. Y. Lee
    H. W. Lim
    H. W. Lee
    J. E. Park
    T. H. Woo
    J. E. Oh
    Journal of Digital Imaging, 2019, 32 : 478 - 488
  • [43] "Dose of the day" based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy
    Yuan, Zilong
    Rong, Yi
    Benedict, Stanley H.
    Daly, Megan E.
    Qiu, Jianfeng
    Yamamoto, Tokihiro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 88 - 94
  • [44] Is model-based dose calculation based on cone-beam computed tomography suitable for adaptive treatment planning in brachytherapy?
    Karius, Andre
    Shariff, Maya
    Schaller, Sabrina
    Lotter, Michael
    Strnad, Vratislav
    Lackner, Niklas
    Fietkau, Rainer
    Bert, Christoph
    Merten, Ricarda
    Schweizer, Claudia
    STRAHLENTHERAPIE UND ONKOLOGIE, 2025, 201 (01) : 57 - 70
  • [45] Sparse-view, short-scan, dedicated cone-beam breast computed tomography: image quality assessment
    Tseng, Hsin Wu
    Karellas, Andrew
    Vedantham, Srinivasan
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (06)
  • [46] Assessment of image quality of two cone-beam computed tomography of the Varian Linear accelerators: Comparison with spiral CT simulator
    Ragab, H.
    Abdelaziz, D. M.
    Khalil, M. M.
    Elbakry, M. N. Yasein
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2023, 21 (03): : 491 - 498
  • [47] Low-dose cone-beam CT (LD-CBCT) reconstruction for image-guided radiation therapy (IGRT) by three-dimensional dual-dictionary learning
    Song, Ying
    Zhang, Weikang
    Zhang, Hong
    Wang, Qiang
    Xiao, Qing
    Li, Zhibing
    Wei, Xing
    Lai, Jialu
    Wang, Xuetao
    Li, Wan
    Zhong, Quan
    Gong, Pan
    Zhong, Renming
    Zhao, Jun
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [48] Block-matching sparsity regularization-based image reconstruction for low-dose computed tomography
    Cai, Ailong
    Li, Lei
    Zheng, Zhizhong
    Wang, Linyuan
    Yan, Bin
    MEDICAL PHYSICS, 2018, 45 (06) : 2439 - 2452
  • [49] Sparse reconstruction based on dictionary learning and group structure strategy for cone-beam X-ray luminescence computed tomography
    Chen, Yi
    Du, Mengfei
    Zhang, Gege
    Zhang, Jun
    Li, Kang
    Su, Linzhi
    Zhao, Fengjun
    Yi, Huangjian
    Cao, And Xin
    OPTICS EXPRESS, 2023, 31 (15) : 24845 - 24861
  • [50] Patient-specific calibration of cone-beam computed tomography data sets for radiotherapy dose calculations and treatment plan assessment
    MacFarlane, Michael
    Wong, Daniel
    Hoover, Douglas A.
    Wong, Eugene
    Johnson, Carol
    Battista, Jerry J.
    Chen, Jeff Z.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (02): : 249 - 257