Removal of major interference sources in aqueous near-infrared spectroscopy techniques

被引:25
作者
Chen, D [1 ]
Hu, B [1 ]
Shao, XG [1 ]
Su, QD [1 ]
机构
[1] Univ Sci & Technol China, Dept Chem, Hefei 230026, Anhui, Peoples R China
关键词
extension of wavelet prism (WPe); orthogonal signal correction (OSC); multivariate calibration; aqueous near-infrared spectrum;
D O I
10.1007/s00216-004-2569-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This work describes a hybrid procedure for eliminating major interference sources in aqueous near-infrared (NIR) spectra, that include aqueous influence, noise, and systemic variations irrelevant to concentration. The scheme consists of two parts: extension of wavelet prism (WPe) and orthogonal signal correction (OSC). First, WPe is employed to remove variations due to aqueous absorbance and noise; then OSC is applied to remove systemic spectral variations irrelevant to concentration. Although water possesses strong absorption bands that overshadow and overlap the absorption bands of analytes, along with noise and systematic interference, successful calibration models can be generated by employing the method proposed here. We show that the elimination of major interference sources from the aqueous NIR spectra results in a substantial improvement in the precision of prediction, and reduces the required number of PLS components in the model. In addition, the strategy proposed here can be applied to various analytical data for quantitative purposes as well.
引用
收藏
页码:143 / 148
页数:6
相关论文
共 47 条
  • [1] Direct orthogonalization
    Andersson, CA
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 47 (01) : 51 - 63
  • [2] DETERMINATION OF PHYSIOLOGICAL LEVELS OF GLUCOSE IN AN AQUEOUS MATRIX WITH DIGITALLY FILTERED FOURIER-TRANSFORM NEAR-INFRARED SPECTRA
    ARNOLD, MA
    SMALL, GW
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (14) : 1457 - 1464
  • [3] Prediction of rice starch quality parameters by near-infrared reflectance spectroscopy
    Bao, JS
    Cai, YZ
    Corke, H
    [J]. JOURNAL OF FOOD SCIENCE, 2001, 66 (07) : 936 - 939
  • [4] STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA
    BARNES, RJ
    DHANOA, MS
    LISTER, SJ
    [J]. APPLIED SPECTROSCOPY, 1989, 43 (05) : 772 - 777
  • [5] Analysis of aqueous solutions by near-infrared spectrometry (NIRS) .4. One- and two-component systems of organic compounds in water
    Berentsen, S
    Stolz, T
    Molt, K
    [J]. JOURNAL OF MOLECULAR STRUCTURE, 1997, 410 : 581 - 585
  • [6] Effect of orthogonal signal correction on the determination of compounds with very similar near infrared spectra
    Bertran, E
    Iturriaga, H
    Maspoch, S
    Montoliu, I
    [J]. ANALYTICA CHIMICA ACTA, 2001, 431 (02) : 303 - 311
  • [7] Orthogonal signal correction in near infrared calibration
    Blanco, M
    Coello, J
    Montoliu, I
    Romero, MA
    [J]. ANALYTICA CHIMICA ACTA, 2001, 434 (01) : 125 - 132
  • [8] On-line monitoring of starch enzymatic hydrolysis by near-infrared spectroscopy
    Blanco, M
    Coello, J
    Iturriaga, H
    Maspoch, S
    Banó, RG
    [J]. ANALYST, 2000, 125 (04) : 749 - 752
  • [9] NTR calibration in non-linear systems:: different PLS approaches and artificial neural networks
    Blanco, M
    Coello, J
    Iturriaga, H
    Maspoch, S
    Pagès, J
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2000, 50 (01) : 75 - 82
  • [10] Chaupart N, 1998, JOURNAL OF NEAR INFRARED SPECTROSCOPY, VOL 6 1998, P307