Generalized Cystic Resolution: A Metric for Assessing the Fundamental Limits on Beamformer Performance

被引:13
作者
Guenther, Drake A. [1 ]
Walker, William F. [1 ]
机构
[1] Univ Virginia, Dept Biomed Engn, Charlottesville, VA 22903 USA
关键词
OPTIMAL APODIZATION DESIGN; CONSTRAINED LEAST-SQUARES; ULTRASOUND;
D O I
10.1109/TUFFC.2009.1007
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Existing methods for characterizing the imaging performance of ultrasound systems do not clearly quantify the impact of contrast, spatial resolution, and signal-to-noise ratio (SNR). Although the beamplot, contrast resolution metrics, SNR measurements, ideal observer methods, and contrast-detail analysis provide useful information, it remains difficult to discern how changes in system parameters affect these metrics and clinical imaging performance. In this paper, we present a rigorous methodology for characterizing the pulse-echo imaging performance of arbitrary ultrasound systems. Our metric incorporates the 4-D spatio-temporal system response, which is defined as a function of the individual beamformer channel weights. The metric also incorporates the individual beamformer channel electronic SNR. Whereas earlier performance measures dealt solely with contrast resolution or cello signal-to-noise ratio, our metric combines them so that tradeoffs between these parameters are easily distinguishable. The new metric quantifies all arbitrary systems contrast resolution and SNR performance as it function of cyst sized beamformer channel weights, and beamformer channel SNR. We present a theoretical derivation of the unified performance metric and provide simulation and experimental results highlighting the metric's utility. We compare the fundamental performance limits of 2 beamforming strategies: the dynamic focus finite impulse response (FIR) filter beamformer and the spatial matched filter (SMF) beamformer to the performance of the conventional delay-and-sum (DAS) beamformer. Results from this study show that the SMF beamformer and the FIB, beamformer offer significant gains in beamformer SNR and contrast resolution compared with the DAS beamformer, respectively. The metric clearly distinguishes the performance of the SMF beamformer, which enhances system sensitivity, from the FIR beamformer, which optimizes system contrast resolution. Finally, the metric provides one quantitative goal for optimizing a broadband beamformer's contrast resolution performance.
引用
收藏
页码:77 / 90
页数:14
相关论文
共 24 条
[1]   Observer efficiency in discrimination tasks simulating malignant and benign breast lesions imaged with ultrasound [J].
Abbey, CK ;
Zemp, RJ ;
Liu, J ;
Lindfors, KK ;
Insana, MF .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (02) :198-209
[2]   A spline-based approach for computing spatial impulse responses [J].
Ellis, Michael A. ;
Guenther, Drake ;
Walker, William F. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (05) :1045-1054
[3]  
ER MH, 1985, IEEE J OCEANIC ENG, V10, P231, DOI 10.1109/JOE.1985.1145099
[4]  
GUENTHER DA, BROADBAND OPTI UNPUB
[5]  
GUENTHER DA, 2007, P 2007 SPIE S MED IM
[6]   Optimal apodization design for medical ultrasound using constrained least squares - Part I: Theory [J].
Guenther, Drake A. ;
Walker, William F. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (02) :332-342
[7]   Optimal apodization design for medical ultrasound using constrained least squares - Part II: Simulation results [J].
Guenther, Drake A. ;
Walker, William F. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (02) :343-358
[8]  
Jensen JA, 2001, ULTRASON, P1507, DOI 10.1109/ULTSYM.2001.992006
[9]   Contrast response analysis for medical ultrasound imaging [J].
Johnson, R .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (04) :805-809
[10]   Efficient array beam forming by spatial filtering for ultrasound B-mode imaging [J].
Kim, Kang-Sik ;
Liu, Jie ;
Insana, Michael F. .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2006, 120 (02) :852-861