Biomechanical comparison of femoral fixation devices for anterior cruciate ligament reconstruction using a novel testing method

被引:8
|
作者
Ehrensberger, Mark [1 ,2 ]
Hohman, Donald W., Jr. [2 ]
Duncan, Kurt [2 ]
Howard, Craig [2 ]
Bisson, Leslie [2 ]
机构
[1] SUNY Buffalo, Dept Biomed Engn, Buffalo, NY 14260 USA
[2] SUNY Buffalo, Dept Orthopaed Surg, Buffalo, NY 14260 USA
关键词
Anterior cruciate ligament (ACL); Biomechanics; Femoral anchor; Graft fixation; HAMSTRING TENDON GRAFT; INTERFERENCE SCREW FIXATION; IN-VITRO; PORCINE MODEL; PULL-OUT; STRENGTH; AUGMENTATION; TITANIUM; SITE;
D O I
10.1016/j.clinbiomech.2012.12.007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: A novel biomechanical test method was implemented to compare the mechanical performance of two femoral fixation anchors (AperFix(r), Cayenne Medical, Scottsdale, AZ, USA or the AppianFx(r), KFx Medical, Carlsbad, CA, USA) that were utilized in anterior cruciate ligament reconstruction. Methods: Anterior cruciate ligament reconstructions were performed in 20 porcine femurs by using bovine extensor tendon grafts secured with 9 mm femoral anchors (AperFix(r) or AppianFx(r)). 10 specimens were tested for each anchor type. Infrared position sensors determined the repair construct displacements during conditioning (20 cycles at 5-50 N at 0.25 Hz), cyclic loading (1500 cycles at 50-200 N at 1 Hz), and ultimate loading (150 mm/min). Outcomes included tendon elongation, anchor displacement, stiffness, maximum load, yield load, and load at 5mm of anchor displacement. It was hypothesized that there would be no differences in the outcomes of these two devices. Independent measure t-tests compared the performance of the devices (p<0.05). Findings: The performance of the two anchors was comparable during the cyclic loading. During ultimate loading, a statistically higher yield load (p<0.01) and a load at 5 mm of anchor displacement (p<0.01) were demonstrated for the AppianFx(r) as compared to AperFix(r). Maximum load and stiffness were not significantly different. Interpretation: Given the good clinical track record of the AperFix(r), the comparable, and in some cases superior, the biomechanical data presented here for the AppianFx(r) are encouraging for their clinical implementation. This study also introduced a novel test method that directly tracks the relevant construct displacements during cyclic and ultimate loading tests of the anterior cruciate ligament reconstructions. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:193 / 198
页数:6
相关论文
共 50 条
  • [31] Stiffer Fixation of the Tibial Double-Tunnel Anterior Cruciate Ligament Complex Versus the Single Tunnel: A Biomechanical Study
    Meuffels, Duncan E.
    Docter, Pieter T.
    van Dongen, Roland A.
    Kleinrensink, Gert-Jan
    Verhaar, Jan A. N.
    Reijman, Max
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2010, 26 (09) : S35 - S40
  • [32] Biomechanical Comparison of Fixed-Loop and Adjustable-Loop Cortical Suspensory Devices for Metaphyseal Femoral-Sided Soft Tissue Graft Fixation in Anatomic Anterior Cruciate Ligament Reconstruction Using a Porcine Model
    Nye, Darin D.
    Mitchell, W. Ryan
    Liu, Wei
    Ostrander, Roger V.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2017, 33 (06) : 1225 - +
  • [33] Intraoperative complications using the Bio-Transfix femoral fixation implant in anterior cruciate ligament reconstruction
    Kokkinakis, Michail
    Ashmore, Alexander
    El-Guindi, Magdi
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (03) : 375 - 379
  • [34] Hybrid Tibia Fixation of Soft Tissue Grafts in Anterior Cruciate Ligament Reconstruction: A Systematic Review
    Balazs, George C.
    Brelin, Alaina M.
    Grimm, Patrick D.
    Dickens, Jonathan F.
    Keblish, David J.
    Rue, John-Paul H.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2016, 44 (10) : 2724 - 2732
  • [35] A Comparison Between a Retrograde Interference Screw, Suture Button, and Combined Fixation on the Tibial Side in an All-Inside Anterior Cruciate Ligament Reconstruction A Biomechanical Study in a Porcine Model
    Walsh, Michael P.
    Wijdicks, Coen A.
    Parker, Josh B.
    Hapa, Onur
    LaPrade, Robert F.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2009, 37 (01) : 160 - 167
  • [36] Anterior cruciate ligament femoral side retained stump technique reduces enlargement of the femoral bone tunnel after anterior cruciate ligament reconstruction
    Li, Xiaobo
    Li, Hanlin
    Su, Jixian
    Ding, Ran
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [37] Biomechanical comparison of three techniques for fixation of tibial avulsion fractures of the anterior cruciate ligament
    Yong In
    Dai-Soon Kwak
    Chan-Woong Moon
    Seung-Ho Han
    Nam-Yong Choi
    Knee Surgery, Sports Traumatology, Arthroscopy, 2012, 20 : 1470 - 1478
  • [38] Biomechanical comparison of three techniques for fixation of tibial avulsion fractures of the anterior cruciate ligament
    In, Yong
    Kwak, Dai-Soon
    Moon, Chan-Woong
    Han, Seung-Ho
    Choi, Nam-Yong
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (08) : 1470 - 1478
  • [39] Femoral Suspension Devices for Anterior Cruciate Ligament Reconstruction Do Adjustable Loops Lengthen?
    Barrow, Aaron E.
    Pilia, Marcello
    Guda, Teja
    Kadrmas, Warren R.
    Burns, Travis C.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2014, 42 (02) : 343 - 349
  • [40] Serial dilation versus extraction drilling in anterior cruciate ligament reconstruction: a biomechanical study
    Sorensen, O. G.
    Jakobsen, B. W.
    Kold, S.
    Hansen, T. B.
    Soballe, K.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (06) : 742 - 746