Robust optimal design of building cooling systems considering cooling load uncertainty and equipment reliability

被引:65
|
作者
Gang, Wenjie [1 ]
Wang, Shengwei [1 ]
Xiao, Fu [1 ]
Gao, Dian-ce [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
Robust design; Optimal design; Uncertainty analysis; Reliability analysis; Cooling system; AVAILABILITY;
D O I
10.1016/j.apenergy.2015.08.070
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Appropriate design provides the cooling system to achieve good performance with low energy consumption and cost. Conventional design method in heating, ventilation and air-conditioning (HVAC) field usually selects the cooling system based on certain cooling load and experiences. The performance of the selected cooling system may deviate from the expectations due to cooling load uncertainty. This paper proposes a novel design method to obtain the robust optimal cooling systems for buildings by quantifying the uncertainty in cooling load calculation and equipment reliability in operation comprehensively. By quantifying the cooling load uncertainty with Monte Carlo method and chiller reliability using Markov method, the robust optimal cooling system is obtained with minimum annual total cost. By applying the new method in the design of the cooling system for a building, its function and performance as well as potential benefits are demonstrated and evaluated. Results show that the proposed method can obtain the optimal cooling systems with low cost and high robustness and provides a promising means for designers to make their best design decisions based on quantitative assessment according to their priority. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:265 / 275
页数:11
相关论文
共 50 条
  • [41] Reliability and Maintenance Prioritization Analysis of Combined Cooling, Heating and Power Systems
    Jiang, Jinming
    Wei, Xindong
    Gao, Weijun
    Kuroki, Soichiro
    Liu, Zhonghui
    ENERGIES, 2018, 11 (06):
  • [42] Office building cooling load reduction using thermal analysis method - A case study
    Nazi, Wan Iman Wan Mohd
    Royapoor, Mohammad
    Wang, Yaodong
    Roskilly, Anthony Paul
    APPLIED ENERGY, 2017, 185 : 1574 - 1584
  • [43] Optimal design of a regenerative heat and mass exchanger for indirect evaporative cooling
    Fakhrabadi, Farbod
    Kowsary, Farshad
    APPLIED THERMAL ENGINEERING, 2016, 102 : 1384 - 1394
  • [44] Design optimisation of a hybrid electric vehicle cooling system considering performance and packaging
    Lee, Kwang Jae
    Kang, Namwoo
    Kokkolaras, Michael
    Papalambros, Panos Y.
    INTERNATIONAL JOURNAL OF VEHICLE DESIGN, 2021, 85 (2-4) : 154 - 177
  • [45] Uncertainty Analysis of Weather Forecast Data for Cooling Load Forecasting Based on the Monte Carlo Method
    Zhao, Jing
    Duan, Yaoqi
    Liu, Xiaojuan
    ENERGIES, 2018, 11 (07):
  • [46] The Tools and Parameters to Consider in the Design of Power Transformer Cooling Systems
    Goscinski, Przemyslaw
    Nadolny, Zbigniew
    Nawrowski, Ryszard
    Boczar, Tomasz
    ENERGIES, 2023, 16 (24)
  • [47] A new method for the automated design of cooling systems in injection molds
    Manuel Mercado-Colmenero, Jorge
    Angel Rubio-Paramio, Miguel
    de Juanes Marquez-Sevillano, Juan
    Martin-Donate, Cristina
    COMPUTER-AIDED DESIGN, 2018, 104 : 60 - 86
  • [48] Optimal design of residential cogeneration systems under uncertainty
    Fabian Fuentes-Cortes, Luis
    Ezequiel Santibanez-Aguilar, Jose
    Maria Ponce-Ortega, Jose
    COMPUTERS & CHEMICAL ENGINEERING, 2016, 88 : 86 - 102
  • [49] Reliability of Example Mechanical Systems for Data Center Cooling Selected by Tier Classification
    Arno, Robert
    Githu, Gardson
    Gross, Peter
    Schuerger, Robert
    Wilson, Scott
    2010 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2010,
  • [50] OPTIMAL DESIGN FOR MINIMIZING UNCERTAINTY IN DYNAMIC EQUILIBRIUM SYSTEMS
    Banks, H. T.
    Baraldi, R.
    Flores, K.
    EURASIAN JOURNAL OF MATHEMATICAL AND COMPUTER APPLICATIONS, 2015, 3 (01): : 23 - 47