Computer-guided implant surgery and immediate loading with a modifiable radiographic template in a patient with partial edentulism: A clinical report

被引:5
作者
Lanis, Alejandro [1 ]
Padial-Molina, Miguel [2 ,3 ]
Gamil, Rami [4 ]
del Canto, Orlando Alvarez [5 ]
机构
[1] Univ San Sebastian, Sch Dent, Oral Implantol, Santiago, Chile
[2] Univ Granada, Sch Dent, Dept Oral Surg & Implant Dent, Granada, Spain
[3] Univ Granada, Res Grp CTS583, Implantol & Periodont, Granada, Spain
[4] Univ Insubria, Dept Surg & Morphol Sci, Digital Dent, Varese, Italy
[5] Univ Desarrollo, Sch Dent, Oral lmplantol, Santiago, Chile
关键词
CONSENSUS STATEMENTS; AESTHETIC OUTCOMES; PLACEMENT; ACCURACY; MAXILLA;
D O I
10.1016/j.prosdent.2015.03.012
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Computer-guided implant surgery in fresh extraction sites is an underdeveloped procedure. The presence of teeth that will be extracted makes the creation of an appropriate radiographic template for virtual simulation of the rehabilitation impossible. A modified radiographic template is presented to define a digital restorative simulation for the maxillary rehabilitation of a patient with partial edentulism. This modification enables 3-dimensional prosthetic virtual information in regions where teeth will be extracted.
引用
收藏
页码:328 / 334
页数:7
相关论文
共 34 条
  • [1] Computer-guided implant surgery for immediate implanting and loading: The STIL technique
    Granata, Stefano
    Sforza, Nicola Marco
    Giberti, Lorenzo
    Stellini, Edoardo
    Di Fiore, Adolfo
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (02) : 155 - 163
  • [2] A SUBTRACTIVE RADIOGRAPHIC TEMPLATE FOR COMPUTER-GUIDED SURGERY
    Marchack, Christopher B.
    Charles, Allan
    Matosian, Alex J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (04) : 1006 - 1008
  • [3] Mandibular Rehabilitation Using Immediate Implant Loading After Computer-Guided Surgery
    Margonar, Rogerio
    Queiroz, Thallita P.
    Luvizuto, Eloa R.
    Betoni-Junior, Walter
    Zocal, Emilio A. C.
    JOURNAL OF CRANIOFACIAL SURGERY, 2012, 23 (02) : E129 - E132
  • [4] Digital Workflow for Computer-Guided Implant Surgery in Edentulous Patients: A Case Report
    Oh, Ji-Hyeon
    An, Xueyin
    Jeong, Seung-Mi
    Choi, Byung-Ho
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 75 (12) : 2541 - 2549
  • [5] Clinical Accuracy of Flapless Computer-Guided Surgery for Implant Placement in Edentulous Arches
    Vieira, Dalton Marinho
    Sotto-Maior, Bruno Salles
    Villaca de Souza Barros, Carlos Alberto
    Reis, Elson Simoes
    Francischone, Carlos Eduardo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (05) : 1347 - 1351
  • [6] COMPUTER-GUIDED IMPLANT INSERTION IN A PATIENT WITH IMPACTED MAXILLARY CANINES: CASE REPORT
    Lico, S.
    Andrisani, C.
    Bassi, M. Andreasi
    Candotto, V.
    Silvestre, F. J.
    Lauritano, D.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2017, 31 (02) : 247 - 251
  • [7] Computer-assisted, template-guided immediate implant placement and loading in the mandible: a case report
    Spielau, Thomas
    Hauschild, Uli
    Katsoulis, Joannis
    BMC ORAL HEALTH, 2019, 19
  • [8] A New Radiologic Protocol and a New Occlusal Radiographic Index for Computer-Guided Implant Surgery
    De Santis, Daniele
    Graziani, Pierfrancesco
    Castellani, Roberto
    Zanotti, Guglielmo
    Gelpi, Federico
    Marconcini, Simone
    Bertossi, Dario
    Nocini, Pier Francesco
    JOURNAL OF CRANIOFACIAL SURGERY, 2016, 27 (05) : E506 - E510
  • [9] A survey of the satisfaction of patients who have undergone implant surgery with and without employing a computer-guided implant surgical template
    Youk, Shin-Young
    Lee, Jee-Ho
    Park, Ji-Man
    Heo, Seong-Joo
    Roh, Hyun-Ki
    Park, Eun-Jin
    Shin, Im Hee
    JOURNAL OF ADVANCED PROSTHODONTICS, 2014, 6 (05) : 395 - 405
  • [10] A Fully Guided Sequential Template Immediate Loading Protocol for Dual-Arch Implant Surgery
    Alruhailie, Lamia
    Zaidan, Aliyaa
    Alasmari, Abeer
    Raffa, Ossama
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2024, 16 : 167 - 177