A highly sensitive electrochemical sensor for simultaneous detection of uric acid, xanthine and hypoxanthine based on poly(L-methionine) modified glassy carbon electrode

被引:105
作者
Ojani, Reza [1 ]
Alinezhad, Ali [1 ]
Abedi, Zahra [1 ]
机构
[1] Univ Mazandaran, Fac Chem, Dept Analyt Chem, Electroanalyt Chem Res Lab, Babol Sar, Iran
关键词
Poly L-met hionine; Uric acid; Xanthine; Hypoxanthine; Cyclic voltammetry; Differential pulse voltammetry; CAPILLARY-ELECTROPHORESIS; VOLTAMMETRIC DETERMINATION; D-SERINE; QUANTIFICATION; EPINEPHRINE; NANOTUBES; ALLANTOIN; DOPAMINE; OXIDASE; NAFION;
D O I
10.1016/j.snb.2013.07.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A poly L-methionine modified GC electrode was fabricated by electrochemical polymerization of the L-methionine on a glassy carbon electrode. The electrochemical behaviors of uric acid, xanthine and hypoxanthine at the modified electrode were studied by cyclic voltammetry and differential pulse voltammetry. The results showed that this modified electrode exhibited excellent electrocatalytic activity toward the oxidation of the uric acid, xanthine and hypoxanthine. Also, electrode was used for simultaneous determination of uric acid, xanthine and hypoxanthine. This modified electrode possesses high sensitivity, and the detection limits as values 0.007, 0.004 and 0.008 mu M for uric acid, xanthine and hypoxanthine, respectively. Finally, the poly L-methionine modified electrode was successfully employed to detect uric acid, xanthine and hypoxanthine in the serum samples with good selectivity and high sensitivity. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:621 / 630
页数:10
相关论文
共 42 条
[1]   STUDY OF PURINE UTILIZATION AND EXCRETION IN XANTHINURIC MAN [J].
AYVAZIAN, JH ;
SKUPP, S .
JOURNAL OF CLINICAL INVESTIGATION, 1965, 44 (07) :1248-&
[2]  
Bard A.J., 2022, Electrochemical Methods: Fundamentals and Applications
[3]  
Bhagavan NV, 2002, MED BIOCH
[4]   Preparation, characterization, and electrocatalytic activity of surface anchored, Prussian blue containing Starburst PAMAM dendrimers on gold electrodes [J].
Bustos, E ;
Manríquez, J ;
Orozco, G ;
Godínez, LA .
LANGMUIR, 2005, 21 (07) :3013-3021
[5]  
Carlucci F, 2000, ELECTROPHORESIS, V21, P1552, DOI 10.1002/(SICI)1522-2683(20000501)21:8<1552::AID-ELPS1552>3.3.CO
[6]  
2-D
[7]   Amperometric detection of uric acid and hypoxanthine with Xanthine oxidase immobilized and carbon based screen-printed electrode. Application for fish freshness determination [J].
Carsol, MA ;
Volpe, G ;
Mascini, M .
TALANTA, 1997, 44 (11) :2151-2159
[8]   Simultaneous determination of allantoin, hypoxanthine, xanthine, and uric acid in serum/plasma by CE [J].
Causse, Elizabeth ;
Pradelles, Aude ;
Dirat, Beatrice ;
Negre-Salvayre, Anne ;
Salvayre, Robert ;
Couderc, Francois .
ELECTROPHORESIS, 2007, 28 (03) :381-387
[9]   Quantification of uric acid, xanthine and hypoxanthine in human serum by HPLC for pharmacodynamic studies [J].
Cooper, Nancy ;
Khosravan, Reza ;
Erdmann, Carol ;
Fiene, John ;
Lee, Jean W. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 837 (1-2) :1-10
[10]   Examination of performance of glassy carbon paste electrode modified with gold nanoparticle and xanthine oxidase for xanthine and hypoxanthine detection [J].
Cubukcu, Meliha ;
Timur, Suna ;
Anik, Uelkue .
TALANTA, 2007, 74 (03) :434-439