Focusing optics of a parallel beam CCD optical tomography apparatus for 3D radiation gel dosimetry

被引:52
|
作者
Krstajic, Nikola [1 ]
Doran, Simon J. [1 ]
机构
[1] Univ Surrey, Dept Phys, Guildford GU2 7XH, Surrey, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 08期
关键词
D O I
10.1088/0031-9155/51/8/007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Optical tomography of get dosimeters is a promising and cost-effective avenue for quality control of radiotherapy treatments such as intensity-modulated radiotherapy (IMRT). Systems based on a laser coupled to a photodiode have so far shown the best results within the context of optical scanning of radiosensitive gels, but are very slow (similar to 9 min per slice) and poorly suited to measurements that require many slices. Here, we describe a fast, three-dimensional (3D) optical computed tomography (optical-CT) apparatus, based on a broad, collimated beam, obtained from a high power LED and detected by a charged coupled detector (CCD). The main advantages of such a system are (i) an acquisition speed approximately two orders of magnitude higher than a laser-based system when 3D data are required, and (ii) a greater simplicity of design. This paper advances our previous work by introducing a new design of focusing optics, which take information from a suitably positioned focal plane and project an image onto the CCD. An analysis of the ray optics is presented, which explains the roles of telecentricity, focusing, acceptance angle and depth-of-field (DOF) in the formation of projections. A discussion of the approximation involved in measuring the line integrals required for filtered backprojection reconstruction is given. Experimental results demonstrate (i) the effect on projections of changing the position of the focal plane of the apparatus, (ii) how to measure the acceptance angle of the optics, and (iii) the ability of the new scanner to image both absorbing and scattering gel phantoms. The quality of reconstructed images is very promising and suggests that the new apparatus may be useful in a clinical setting for fast and accurate 3D dosimetry.
引用
收藏
页码:2055 / 2075
页数:21
相关论文
共 50 条
  • [31] High resolution 3D dosimetry for microbeam radiation therapy using optical CT
    McErlean, C.
    Braeuer-Krisch, E.
    Adamovics, J.
    Leach, M. O.
    Doran, S. J.
    8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [32] Clinical 3D Dosimetry in Modern Radiation Therapy
    Mihailidis, Dimitris
    MEDICAL PHYSICS, 2020, 47 (01) : 290 - 291
  • [33] 3D gel Dosimetry of IMSRT using normoxic MAGAT polymer gel
    Beiki-Ardakani, A
    Heydarian, M
    Vitkin, A
    Kirilova, A
    Princess, DJA
    MEDICAL PHYSICS, 2005, 32 (06) : 1978 - 1979
  • [34] Investigation of 3D gram materials for radiation dosimetry
    Readshaw, AK
    Brown, GO
    Phillips, GW
    Weiss, RG
    Guardala, NA
    Price, JL
    Mueller, SC
    Moscovitch, M
    RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 451 - 454
  • [35] On the chemical stability of 3D monomer/polymer gel dosimetry
    De Deene, Y
    De Wagter, C
    Achten, E
    De Neve, W
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 380 - 382
  • [36] Imaging Protocol Investigations with a Fan-Beam Optical CT Scanner for 3D Dosimetry
    Campbell, W.
    Jirasek, A.
    Wells, D.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [37] A study of geometrical and reconstruction artifacts in 3D gel-dosimetry utilizing optical-CT
    Oldham, M
    Kim, L
    MEDICAL PHYSICS, 2003, 30 (06) : 1426 - 1426
  • [38] Investigation of Proton Beam Dose Distributions with 3D Dosimetry
    Grant, R.
    Ibbott, G.
    Zhu, X.
    Adamovics, J.
    Oldham, M.
    Followill, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S885 - S886
  • [39] Optical cone beam tomography of Cherenkov-mediated signals for fast 3D dosimetry of x-ray photon beams in water
    Glaser, Adam K.
    Andreozzi, Jacqueline M.
    Zhang, Rongxiao
    Pogue, Brian W.
    Gladstone, David J.
    MEDICAL PHYSICS, 2015, 42 (07) : 4127 - 4136
  • [40] Preliminary Investigation of a Novel 3D Dosimetry System Consisting of ClearView 3D Radiochromic Dosimeters with Telecentric Optical Computed Tomography Scanning