Focusing optics of a parallel beam CCD optical tomography apparatus for 3D radiation gel dosimetry

被引:52
作者
Krstajic, Nikola [1 ]
Doran, Simon J. [1 ]
机构
[1] Univ Surrey, Dept Phys, Guildford GU2 7XH, Surrey, England
关键词
D O I
10.1088/0031-9155/51/8/007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Optical tomography of get dosimeters is a promising and cost-effective avenue for quality control of radiotherapy treatments such as intensity-modulated radiotherapy (IMRT). Systems based on a laser coupled to a photodiode have so far shown the best results within the context of optical scanning of radiosensitive gels, but are very slow (similar to 9 min per slice) and poorly suited to measurements that require many slices. Here, we describe a fast, three-dimensional (3D) optical computed tomography (optical-CT) apparatus, based on a broad, collimated beam, obtained from a high power LED and detected by a charged coupled detector (CCD). The main advantages of such a system are (i) an acquisition speed approximately two orders of magnitude higher than a laser-based system when 3D data are required, and (ii) a greater simplicity of design. This paper advances our previous work by introducing a new design of focusing optics, which take information from a suitably positioned focal plane and project an image onto the CCD. An analysis of the ray optics is presented, which explains the roles of telecentricity, focusing, acceptance angle and depth-of-field (DOF) in the formation of projections. A discussion of the approximation involved in measuring the line integrals required for filtered backprojection reconstruction is given. Experimental results demonstrate (i) the effect on projections of changing the position of the focal plane of the apparatus, (ii) how to measure the acceptance angle of the optics, and (iii) the ability of the new scanner to image both absorbing and scattering gel phantoms. The quality of reconstructed images is very promising and suggests that the new apparatus may be useful in a clinical setting for fast and accurate 3D dosimetry.
引用
收藏
页码:2055 / 2075
页数:21
相关论文
共 39 条
[1]  
Adamovics J., 2004, Journal of Physics: Conference Series, V3, P172, DOI 10.1088/1742-6596/3/1/020
[2]   IMAGING OF RADIATION-DOSE BY VISIBLE COLOR DEVELOPMENT IN FERROUS-AGAROSE-XYLENOL ORANGE GELS [J].
APPLEBY, A ;
LEGHROUZ, A .
MEDICAL PHYSICS, 1991, 18 (02) :309-312
[3]   Optical imaging in medicine .2. Modelling and reconstruction [J].
Arridge, SR ;
Hebden, JC .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (05) :841-853
[4]   Three-dimensional radiation dose measurements with ferrous benzoic acid xylenol orange in gelatin gel and optical absorption tomography [J].
Bero, MA ;
Gilboy, WB ;
Glover, PM ;
Keddie, JL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3) :617-620
[5]  
Born M., 1999, PRINCIPLES OPTICS
[6]  
De Deene Y., 2004, Journal of Physics: Conference Series, V3, P87, DOI 10.1088/1742-6596/3/1/009
[7]  
De Deene Y., 2004, Journal of Physics: Conference Series, V3, P34, DOI 10.1088/1742-6596/3/1/006
[8]   A CCD-based optical CT scanner for high-resolution 3D imaging of radiation dose distributions: equipment specifications, optical simulations and preliminary results [J].
Doran, SJ ;
Koerkamp, KK ;
Bero, MA ;
Jenneson, P ;
Morton, EJ ;
Gilboy, WB .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (12) :3191-3213
[9]   Three-dimensional imaging of single isolated cell nuclei using optical projection tomography [J].
Fauver, M ;
Seibel, EJ ;
Rahn, JR ;
Meyer, MG ;
Patten, FW ;
Neumann, T ;
Nelson, AC .
OPTICS EXPRESS, 2005, 13 (11) :4210-4223
[10]  
Fercher AF, 2003, REP PROG PHYS, V66, P239, DOI [10.1088/0034-4885/66/2/204, 10.2184/lsj.31.635]