Performance evaluation of a continuous flow inclined solar still desalination system

被引:79
|
作者
El-Agouz, S. A. [1 ]
El-Samadony, Y. A. F. [1 ]
Kabeel, A. E. [1 ]
机构
[1] Tanta Univ, Fac Engn, Dept Power Mech Engn, Tanta, Egypt
关键词
Theoretical study; Continuous water flow; Inclined solar still; Desalination; ENHANCEMENT;
D O I
10.1016/j.enconman.2015.05.069
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the present work, theoretical study of the performance evaluation of a continuous water flow inclined solar still desalination system is performed. Three models are studied for inclined solar still desalination system with and without water close loop. The effects of the water mass, water film thickness, water film velocity and air wind velocity on the performance of the three models are studied. The results show that the inclined solar still with a makeup water is superior in productivity (57.2% improvement) compared with a conventional basin-type solar still. Also, the application of inclined solar still with open water loop is recommended when combined with other still desalination system due to high water temperature output. The inclined solar still with a makeup (Model 3) gives the highest performance while Model 1 gives the lowest performance. Finally, the water film thickness, and velocity as well as wind velocity plays important roles in improving the still productivity and efficiency. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:606 / 615
页数:10
相关论文
共 50 条
  • [31] A new hybrid desalination system using wicks/solar still and evacuated solar water heater
    Omara, Z. M.
    Eltawil, Mohamed A.
    ElNashar, ElSayed A.
    DESALINATION, 2013, 325 : 56 - 64
  • [32] Recent advances in solar still technology for solar water desalination
    Tony, Maha A.
    Nabwey, Hossam A.
    APPLIED WATER SCIENCE, 2024, 14 (07)
  • [33] Comprehensive investigation of water film thickness effects on the heat and mass transfer of an inclined solar still
    Oliveira de Paula, Ana Carolina
    Radi Ismail, Kamal Abdel
    DESALINATION, 2021, 500 (500)
  • [34] Performance evaluation of different configurations of solar humidification-dehumidification desalination system with subsurface condenser
    Asgari, Behrad
    Bizhani, Mohammadreza
    Hakkaki-Fard, Ali
    Hannani, Siamak Kazemzadeh
    ENERGY CONVERSION AND MANAGEMENT, 2022, 269
  • [35] Effect of continuous and discrete makeup water on the productivity of conventional solar still
    El-Maghlany, Wael M.
    Abdelaziz, Ahmed H.
    Hanafy, Ahmed A.
    Kabeel, A. E.
    JOURNAL OF ENERGY STORAGE, 2020, 28
  • [36] Experimental study to improve the performance of solar still desalination by hydrophobic condensation surface using cold plasma technology
    Khanmohammadi, Shoaib
    Khanjani, Sajjad
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 45 (45)
  • [37] Recent advancements, technologies, and developments in inclined solar still—a comprehensive review
    Hemanth Arun Kumar
    Hariprasath Venkateswaran
    Abd Elnaby Kabeel
    Ali Chamkha
    Muthu Manokar Athikesavan
    Ravishankar Sathyamurthy
    Kamalakannan Kasi
    Environmental Science and Pollution Research, 2021, 28 : 35346 - 35375
  • [38] Design and performance improvement of a solar desalination system by using solar air heater: Experimental and theoretical approach
    Siddiqui, Farooq R.
    Elminshawy, Nabil A. S.
    Addas, Mohammad F.
    DESALINATION, 2016, 399 : 78 - 87
  • [39] Performance enhancement of solar still desalination using sound agitation and condensation: A comparative study
    Immanual, R.
    Kannan, K.
    Sanjana, N.
    Kirthika, K. M.
    DESALINATION AND WATER TREATMENT, 2025, 321
  • [40] Augmentation and evaluation of solar still performance: A comprehensive review
    Elsheikh, Ammar
    Hammoodi, Karrar A.
    Ibrahim, Ahmed Mohamed Mahmoud
    Mourad, Abdel-Hamid I.
    Fujii, Manabu
    Abd-Elaziem, Walaa
    DESALINATION, 2024, 574