Thermal analysis and structural investigation of different dental composite resins

被引:22
作者
Bernardi, M. I. B. [1 ]
Rojas, S. S. [1 ]
Andreeta, M. R. B. [1 ]
Rastelli, A. N. de S. [2 ]
Hernandes, A. C. [1 ]
Bagnato, V. S. [2 ]
机构
[1] Univ Sao Paulo, Inst Fis Sao Carlos, Grp Crescimento Cristais & Mat Ceram, BR-13566590 Sao Carlos, SP, Brazil
[2] Univ Sao Paulo, Inst Fis Sao Carlos, Grp Opt, Sao Carlos, SP, Brazil
关键词
AFM; dental resins; Raman; thermal analysis;
D O I
10.1007/s10973-008-8820-x
中图分类号
O414.1 [热力学];
学科分类号
摘要
The structural and thermal properties of three different dental composite resins, Filtek (TM) Supreme XT, Filtek (TM) Z-250 and TPHA (R)(3) were investigated in this study. The internal structures of uncured and cured resins with blue light-emitting diodes (LEDs) were examined by Micro-Raman spectroscopy. Thermal analysis techniques as DSC, TG and DTG methods were used to investigate the temperature characteristics, as glass transition (T (g) ), degradation, and the thermal stability of the resins. The results showed that the TPHA (R)(3) and Filtek (TM) Supreme XT presented very similar T (g) values, 48 and 50A degrees C, respectively, while the Filtek (TM) Z-250 composite resin presented a higher one, 58A degrees C. AFM microscope was utilized in order to analyze the sample morphologies, which possess different fillers. The composed resin Filtek (TM) Z-250 has a well interconnected more homogeneous morphology, suggesting a better degree of conversion correlated to the glass phase transition temperature. The modes of vibration of interest in the resin were investigated using Raman spectroscopy. It was possible to observe the bands representative for the C=C (1630 cm(-1)) and C=O(1700 cm(-1)) vibrations were studied with respect to their compositions and polymerization. It was observed that the Filtek (TM) Z -250 resin presents the best result related to the thermal properties and polymerization after light curing among the other resins.
引用
收藏
页码:791 / 796
页数:6
相关论文
共 31 条
[1]   EXTENT OF POLYMERIZATION OF DENTAL RESINS BY DIFFERENTIAL SCANNING CALORIMETRY [J].
ANTONUCCI, JM ;
TOTH, EE .
JOURNAL OF DENTAL RESEARCH, 1983, 62 (02) :121-125
[2]  
ANUSAVICE KJ, 2003, PHILLIPS MAT DENT, P376
[3]  
ANUSAVICE KJ, 1998, MAT DENT PHILLIPS SC, P161
[4]   SOME FACTORS INFLUENCING THE DEPTH OF CURE OF VISIBLE LIGHT-ACTIVATED COMPOSITE RESINS [J].
ATMADJA, G ;
BRYANT, RW .
AUSTRALIAN DENTAL JOURNAL, 1990, 35 (03) :213-218
[5]  
DEBASTIANI FS, 2005, INT J BRAZ DENT, V1, P11
[6]   DYNAMIC MECHANICAL-PROPERTIES OF AN INLAY COMPOSITE [J].
DIONYSOPOULOS, P ;
WATTS, DC .
JOURNAL OF DENTISTRY, 1989, 17 (03) :140-144
[7]  
Ferracane J L, 1985, Dent Mater, V1, P11, DOI 10.1016/S0109-5641(85)80058-0
[8]   RATE OF ELUTION OF LEACHABLE COMPONENTS FROM COMPOSITE [J].
FERRACANE, JL ;
CONDON, JR .
DENTAL MATERIALS, 1990, 6 (04) :282-287
[9]   Polymerization of photocurable commercial dental methacrylate-based composites - Photocalorimetry study [J].
Gatti, A. ;
Rastelli, A. N. S. ;
Ribeiro, S. J. L. ;
Messaddeq, Y. ;
Bagnato, V. S. .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2007, 87 (03) :631-634
[10]  
Imazato S, 1995, Dent Mater J, V14, P23