HDR brachytherapy of rectal cancer using a novel grooved-shielding applicator design

被引:23
作者
Webster, Matthew J. [1 ,2 ,3 ]
Devic, Slobodan [4 ,5 ]
Vuong, Te [5 ]
Han, Dae Yup [1 ,2 ,6 ]
Scanderbeg, Dan [1 ,2 ]
Choi, Dongju [1 ,2 ]
Song, Bongyong [1 ,2 ]
Song, William Y. [1 ,2 ]
机构
[1] Univ Calif San Diego, Ctr Adv Radiotherapy Technol, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Radiat Med & Appl Sci, La Jolla, CA 92093 USA
[3] Univ Calif San Diego, Dept Phys, La Jolla, CA 92093 USA
[4] McGill Univ, Med Phys Unit, Montreal, PQ H3G 1A4, Canada
[5] McGill Univ, Jewish Gen Hosp, Dept Radiat Oncol, Montreal, PQ H3T 1E2, Canada
[6] Univ Calif San Diego, Dept Elect & Comp Engn, La Jolla, CA 92093 USA
关键词
DMBT; tungsten shielding; HDR brachytherapy; Monte Carlo; rectal cancer; RATE ENDORECTAL BRACHYTHERAPY; DOSE-RATE BRACHYTHERAPY; MONTE-CARLO; RADIATION; RADIOTHERAPY; DOSIMETRY; CHEMORADIOTHERAPY; RECOMMENDATIONS; SOFTWARE; OUTCOMES;
D O I
10.1118/1.4816677
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this work was to design a novel high-dose rate (HDR) (Ir-192) brachytherapy applicator for treatment of rectal carcinomas that uses tungsten shielding for possibly improved dosimetric results over commercial brachytherapy applicator(s). Methods: A set of 15 single-depth applicators and one dual-depth applicator were designed and simulated using Monte Carlo (MCNPX). All applicators simulated were high-density tungsten alloy cylinders, 16-mm in diameter, and 60-mm long, with longitudinal grooves within which an 192Ir source can be placed. The single-depth designs varied regarding the number and depth of these grooves, ranging from 8 to 16 and 1-mm to 3-mm, respectively. The dual-depth design had ten channels, each of which had two depths at which the source could be placed. Optimized treatment plans were generated for each design on data from 13 treated patients (36 fractions) with asymmetrical clinical target volumes (CTVs). All results were compared against the clinically treated plans which used intracavitary mold applicator (ICMA), as well as a recently designed, highly automated, and collimated intensity modulation device named dynamic modulated brachytherapy (DMBT) device. Results: All applicator designs outperformed the ICMA in every calculated dosimetric criteria, except the total dwell times (similar to 30% increase). There were clear, but relative, tradeoffs regarding both the number of channels and the depth of each channel. Overall, the 12-channel, 1-mm depth, and 14-channel 2-mm depth designs had the best results of the simpler designs, sparing the healthy rectal tissues the most while achieving comparable CTV coverage with the dose heterogeneity index and lateral spill doses improving by over 10% and the contralateral healthy rectum dose dropping over 30% compared to ICMA. The ten-channel dual-depth design outperformed each single-depth design, yielding the best coverage and sparing. Conclusions: New grooved tungsten HDR-brachytherapy devices have been designed and simulated. The results of this work attest to the capability of these new, highly anisotropic, intelligently shielded applicators to limit dose to healthy tissues while maintaining a conformal prescription dose to the CTV. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:10
相关论文
共 31 条
  • [21] PATIENT-SPECIFIC MONTE CARLO DOSE CALCULATIONS FOR HIGH-DOSE-RATE ENDORECTAL BRACHYTHERAPY WITH SHIELDED INTRACAVITARY APPLICATOR
    Poon, Emily
    Williamson, Jeffrey F.
    Vuong, Te
    Verhaegen, Frank
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (04): : 1259 - 1266
  • [22] Dosimetric characterization of a novel intracavitary mold applicator for 192Ir high dose rate endorectal brachytherapy treatment
    Poon, Emily
    Reniers, Brigitte
    Devic, Slobodan
    Vuong, Te
    Verhaegen, Frank
    [J]. MEDICAL PHYSICS, 2006, 33 (12) : 4515 - 4526
  • [23] An approach to using conventional brachytherapy software for clinical treatment planning of complex, Monte Carlo-based brachytherapy dose distributions
    Rivard, Mark J.
    Melhus, Christopher S.
    Granero, Domingo
    Perez-Calatayud, Jose
    Ballester, Facundo
    [J]. MEDICAL PHYSICS, 2009, 36 (06) : 1968 - 1975
  • [24] Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations
    Rivard, MJ
    Coursey, BM
    DeWerd, LA
    Hanson, WF
    Huq, MS
    Ibbott, GS
    Mitch, MG
    Nath, R
    Williamson, JF
    [J]. MEDICAL PHYSICS, 2004, 31 (03) : 633 - 674
  • [25] Validation of a new grid-based Boltzmann equation solver for dose calculation in radiotherapy with photon beams
    Vassiliev, Oleg N.
    Wareing, Todd A.
    McGhee, John
    Failla, Gregory
    Salehpour, Mohammad R.
    Mourtada, Firas
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (03) : 581 - 598
  • [26] THREE-DIMENSIONAL IMAGING IN GYNECOLOGIC BRACHYTHERAPY: A SURVEY OF THE AMERICAN BRACHYTHERAPY SOCIETY
    Viswanathan, Akila N.
    Erickson, Beth A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (01): : 104 - 109
  • [27] Vuong T., 2010, RECTAL CANC INT PERS
  • [28] High Dose Rate Endorectal Brachytherapy for Patients With Curable Rectal Cancer
    Vuong, Te
    Richard, Carole
    Niazi, Tamim
    Liberman, Sender
    Letellier, Francois
    Morin, Nancy
    Hu, Kenneth
    Anderson, Dawn
    Devic, Slobodan
    [J]. SEMINARS IN COLON AND RECTAL SURGERY, 2010, 21 (02) : 115 - 119
  • [29] Dynamic modulated brachytherapy (DMBT) for rectal cancer
    Webster, Matthew J.
    Devic, Slobodan
    Te Vuong
    Han, Dae Yup
    Park, Justin C.
    Scanderbeg, Dan
    Lawson, Joshua
    Song, Bongyong
    Watkins, W. Tyler
    Pawlicki, Todd
    Song, William Y.
    [J]. MEDICAL PHYSICS, 2013, 40 (01)
  • [30] Treatment planning of a skin-sparing conical breast brachytherapy applicator using conventional brachytherapy software
    Yang, Yun
    Melhus, Christopher S.
    Sioshansi, Shirin
    Rivard, Mark J.
    [J]. MEDICAL PHYSICS, 2011, 38 (03) : 1519 - 1525