Photonuclear activation of oxygen & copper with high-energy x-ray or electron beams

被引:0
|
作者
Wong, C. J. [1 ]
Ackerly, T. [1 ,2 ]
Binns, D. [2 ]
Patterson, B. [3 ]
Powell, C. E. [4 ]
Qiao, G. [4 ]
Solomon, D. H. [4 ]
Geso, M. [1 ]
机构
[1] RMIT Univ, Dept Radiat Med, Plenty Rd, Bundoora, Vic, Australia
[2] Peter MacCallum Canc Inst, Melbourne, Vic, Australia
[3] Radiat Oncol victoria, Melbourne, Vic, Australia
[4] Univ Melbourne, Dept Chem & Biomol Engn, Parkville, Vic 3010, Australia
关键词
Photonuclear activation; oxygen; copper; microPET;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Electron or x-ray energies above the threshold for photonuclear activation of certain elements (such as oxygen and copper) can be achieved in some of the high energy beams used today in radiotherapy. Neutrons and gamma radiations are produced in such reactions. These secondary radiations, beside their implications on the treatment, they have potential to be used for quality testing of the radiation beam and can also be imaged with a PET scanner and hence employed for testing such imaging modalities. In this work applications and implications of such secondary radiations in radiotherapy is investigated through oxygen that is in the water molecules inside gel dosimeters and copper in its solid and solution format.
引用
收藏
页码:2126 / +
页数:2
相关论文
共 50 条
  • [41] HIGH-ENERGY X-RAY AND ELECTRON DOSIMETRY - A REVIEW OF THE NEW AAPM PROTOCOL
    SCHULZ, RJ
    MEDICAL PHYSICS, 1983, 10 (04) : 565 - 565
  • [42] EYE SPARING IN HIGH-ENERGY X-RAY-BEAMS
    GALBRAITH, DM
    AGET, H
    LEUNG, PMK
    RIDER, WD
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (03): : 591 - 595
  • [43] THE ADVANTAGES OF EMPLOYING MIXED HIGH ENERGY X-RAY AND ELECTRON BEAMS IN RADIATION THERAPY
    GALE, NH
    INNES, GS
    BRITISH JOURNAL OF RADIOLOGY, 1960, 33 (388): : 261 - 264
  • [44] EXTENSION OF CONCEPT OF TISSUE-AIR RATIOS (TAR) TO HIGH-ENERGY X-RAY BEAMS
    HOLT, JG
    LAUGHLIN, JS
    MORONEY, JP
    RADIOLOGY, 1970, 96 (02) : 437 - &
  • [45] YAP imager and its application with high-energy X-ray beams up to 150 keV
    Hirota, K
    Toyokawa, H
    Suzuki, M
    Kudo, T
    Nomachi, M
    Sugaya, Y
    Yosoi, M
    Gorin, A
    Manuilov, I
    Riazantsev, A
    Kuroda, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 510 (1-2): : 83 - 91
  • [46] Glandular breast dose for monoenergetic and high-energy X-ray beams: Monte Carlo assessment
    Boone, JM
    RADIOLOGY, 1999, 213 (01) : 23 - 37
  • [47] Quality of high-energy X-ray radiotherapy beams: Issues of adequacy of routine experimental verification
    Sharma, S. D.
    JOURNAL OF MEDICAL PHYSICS, 2008, 33 (01) : 1 - 2
  • [48] High-Energy X-ray Radiation Registration Model
    Osipov, S. P.
    Osipov, O. S.
    Ignatenko, K. V.
    5TH INTERNATIONAL CONFERENCE: MODERN TECHNOLOGIES FOR NON-DESTRUCTIVE TESTING, 2017, 189
  • [49] HIGH-ENERGY X-RAY SOURCES IN SOUTHERN SKY
    RICKER, GR
    GERASSIM.M
    MCCLINTO.JE
    RYCKMAN, SG
    LEWIN, WHG
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (02): : 171 - 171
  • [50] HIGH-ENERGY X-RAY OBSERVATIONS OF SOUTHERN SKY
    MCCLINTO.JE
    LEWIN, WHG
    RICKER, GR
    GERASSIM.M
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1972, 17 (10): : 893 - &