Photonuclear activation of oxygen & copper with high-energy x-ray or electron beams

被引:0
|
作者
Wong, C. J. [1 ]
Ackerly, T. [1 ,2 ]
Binns, D. [2 ]
Patterson, B. [3 ]
Powell, C. E. [4 ]
Qiao, G. [4 ]
Solomon, D. H. [4 ]
Geso, M. [1 ]
机构
[1] RMIT Univ, Dept Radiat Med, Plenty Rd, Bundoora, Vic, Australia
[2] Peter MacCallum Canc Inst, Melbourne, Vic, Australia
[3] Radiat Oncol victoria, Melbourne, Vic, Australia
[4] Univ Melbourne, Dept Chem & Biomol Engn, Parkville, Vic 3010, Australia
关键词
Photonuclear activation; oxygen; copper; microPET;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Electron or x-ray energies above the threshold for photonuclear activation of certain elements (such as oxygen and copper) can be achieved in some of the high energy beams used today in radiotherapy. Neutrons and gamma radiations are produced in such reactions. These secondary radiations, beside their implications on the treatment, they have potential to be used for quality testing of the radiation beam and can also be imaged with a PET scanner and hence employed for testing such imaging modalities. In this work applications and implications of such secondary radiations in radiotherapy is investigated through oxygen that is in the water molecules inside gel dosimeters and copper in its solid and solution format.
引用
收藏
页码:2126 / +
页数:2
相关论文
共 50 条
  • [11] MATRIX DOSIMETER TO STUDY UNIFORMITY OF HIGH-ENERGY X-RAY BEAMS
    JOHNS, HE
    RAWLINSON, JA
    TAYLOR, WB
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1974, 120 (01) : 192 - 201
  • [12] Experimental determination of the dose kernel in high-energy x-ray beams
    Ceberg, CP
    Bjarngard, BE
    Zhu, TC
    MEDICAL PHYSICS, 1996, 23 (04) : 505 - 511
  • [13] PERCENTAGE DEPTH DOSE FOR HIGH-ENERGY X-RAY BEAMS IN RADIOTHERAPY
    RAWLINSON, JA
    JOHNS, HE
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1973, 118 (04) : 919 - 922
  • [14] Experimental determination of the dose kernel in high-energy x-ray beams
    Department of Radiation Oncology, Roger Williams Medical Center, Brown University, Providence, RI 02908-4735, United States
    不详
    MED. PHYS., 4 (505-511):
  • [15] Penumbra width correction of clinical high-energy X-ray beams
    Kazi, A
    Sahoo, N
    Hoffman, M
    MEDICAL PHYSICS, 2004, 31 (06) : 1908 - 1908
  • [16] Method for determining photonuclear production of radioisotopes using high-energy electron beams
    Weeks, KJ
    MEDICAL PHYSICS, 1999, 26 (01) : 49 - 54
  • [17] GAUSSIAN QUANTAMETER A NEW INSTRUMENT FOR ENERGY MEASUREMENT ON HIGH-ENERGY X-RAY BEAMS
    KOMAR, AP
    KRUGLOV, SP
    LOPATIN, IV
    SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1967, 11 (09): : 1273 - &
  • [18] A simplistic formalism for calculating entrance dose in high-energy x-ray beams
    Johnsson, SA
    Ceberg, CP
    Nilsson, P
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (22): : 3985 - 3995
  • [19] NEUTRON DOSIMETRY IN HIGH-ENERGY X-RAY BEAMS PRODUCED IN MEDICAL ACCELERATORS
    SOHRABI, M
    MORGAN, KZ
    MCGINLEY, PH
    HEALTH PHYSICS, 1977, 33 (06): : 687 - 687
  • [20] ATTENUATION IN HIGH-ENERGY X-RAY-BEAMS
    BJARNGARD, BE
    SHACKFORD, H