Influence of Ergometer Design on Physiological Responses during Rowing

被引:10
作者
Rossi, J. [1 ]
Piponnier, E. [1 ]
Vincent, L. [1 ]
Samozino, P. [1 ]
Messonnier, L. [1 ]
机构
[1] Univ Savoie Mt Blanc, Lab Exercise Physiol EA4338, F-73370 Le Bourget Du Lac, France
关键词
oxygen uptake; lactate; rowing efficiency; submaximal exercise; LACTATE ACCUMULATION; LDH ACTIVITY; PERFORMANCE; EXERCISE; MUSCLE; ROWERS; MEN; RESISTANCE; EFFICIENCY; EXCHANGE;
D O I
10.1055/s-0035-1548810
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The aim of this study was to compare the physiological responses and rowing efficiency on 2 different rowing ergometers: stationary vs. dynamic ergometers manufactured by Concept2. 11 oarswomen and oarsmen rowed 4min at 60% and 70% of peak power output on both ergometers (randomized order). Power output, stroke rate, heart rate, oxygen uptake, carbon dioxide production, lactate accumulation and rating of perceived exertion were recorded at each stage on the 2 ergometers. Gross and net efficiencies were computed. Exercise intensity was associated with increases in all parameters. Rowing on dynamic ergometer was associated with higher heart rate, oxygen uptake, carbon dioxide production and stroke rate, concomitantly to lower blood lactate accumulation but also to lower gross and net efficiencies. The present study showed that rowing efficiency and blood lactate accumulation were lower on the Concept2 dynamic ergometer than on its stationary counterpart. If the use of the Concept2 dynamic ergometer may provide some advantages (reduced risk of injuries), its utilization requires a specific evaluation of physiological responses during an incremental exercise for an adapted management of training.
引用
收藏
页码:947 / 951
页数:5
相关论文
共 29 条
[1]  
Benson A, 2011, J SPORT SCI MED, V10, P267
[2]   Active muscle and whole body lactate kinetics after endurance training in men [J].
Bergman, BC ;
Wolfel, EE ;
Butterfield, GE ;
Lopaschuk, GD ;
Casazza, GA ;
Horning, MA ;
Brooks, GA .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 87 (05) :1684-1696
[3]  
Bourdin M, 2004, J SPORT MED PHYS FIT, V44, P337
[4]   Peak power output predicts rowing ergometer performance in elite male rowers [J].
Bourdin, M ;
Messonnier, L ;
Hager, JP ;
Lacour, JR .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2004, 25 (05) :368-373
[5]   Fixed versus free-floating stretcher mechanism in rowing ergometers:: Mechanical aspects [J].
Colloud, F ;
Bahuaud, P ;
Doriot, N ;
Champely, S ;
Chèze, L .
JOURNAL OF SPORTS SCIENCES, 2006, 24 (05) :479-493
[6]   PHYSIOLOGICAL ASPECTS OF ROWING [J].
DIPRAMPERO, PE ;
CORTILI, G ;
CELENTANO, F ;
CERRETELLI, P .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (06) :853-+
[7]  
Elliott Bruce, 2002, Sports Biomech, V1, P123, DOI 10.1080/14763140208522791
[8]   CALCULATION OF SUBSTRATE OXIDATION RATES INVIVO FROM GASEOUS EXCHANGE [J].
FRAYN, KN .
JOURNAL OF APPLIED PHYSIOLOGY, 1983, 55 (02) :628-634
[9]   MECHANICAL EFFICIENCY IN ROWING [J].
FUKUNAGA, T ;
MATSUO, A ;
YAMAMOTO, K ;
ASAMI, T .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1986, 55 (05) :471-475
[10]   MUSCULAR EFFICIENCY DURING STEADY-RATE EXERCISE - EFFECTS OF SPEED AND WORK RATE [J].
GAESSER, GA ;
BROOKS, GA .
JOURNAL OF APPLIED PHYSIOLOGY, 1975, 38 (06) :1132-1139