Emergency cricothyrotomy - a systematic review

被引:98
作者
Langvad, Sofie [1 ]
Hyldmo, Per Kristian [2 ,3 ]
Nakstad, Anders Rostrup [4 ]
Vist, Gunn Elisabeth [5 ]
Sandberg, Marten [1 ,4 ]
机构
[1] Univ Oslo, Fac Med, Oslo, Norway
[2] Norwegian Air Ambulance Fdn, Dept Res, Drobak, Norway
[3] Univ Stavanger, Fac Social Sci, Stavanger, Norway
[4] Oslo Univ Hosp, Air Ambulance Dept, N-1474 Nordbyhagen, Norway
[5] Norwegian Knowledge Ctr Hlth Serv, N-0130 Oslo, Norway
关键词
Emergency; Airway management; Cricothyrotomy; Surgical airway; Cannot intubate cannot ventilate; SURGICAL CRICOTHYROIDOTOMY; AIRWAY MANAGEMENT; ENDOTRACHEAL INTUBATION; RANDOMIZED CROSSOVER; MEDICINE RESIDENTS; TRAUMA PATIENTS; DEVICES; SUCCESS; GUIDELINES; EXPERIENCE;
D O I
10.1186/1757-7241-21-43
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: An emergency cricothyrotomy is the last-resort in most airway management protocols and is performed when it is not possible to intubate or ventilate a patient. This situation can rapidly prove fatal, making it important to identify the best method to establish a secure airway. We conducted a systematic review to identify whether there exists superiority between available commercial kits versus traditional surgical and needle techniques. Methods: Medline, EMBASE and other databases were searched for pertinent studies. The inclusion criteria included manikin, animal and human studies and there were no restrictions regarding the professional background of the person performing the procedure. Results: In total, 1,405 unique references were identified; 108 full text articles were retrieved; and 24 studies were included in the review. Studies comparing kits with one another or with various surgical and needle techniques were identified. The outcome measures included in this systematic review were success rate and time consumption. The investigators performing the studies had chosen unique combinations of starting and stopping points for time measurements, making comparisons between studies difficult and leading to many conflicting results. No single method was shown to be better than the others, but the size of the studies makes it impossible to draw firm conclusions. Conclusions: The large majority of the studies were too small to demonstrate statistically significant differences, and the limited available evidence was of low or very low quality. That none of the techniques in these studies demonstrated better results than the others does not necessarily indicate that each is equally good, and these conclusions will likely change as new evidence becomes available.
引用
收藏
页数:14
相关论文
共 49 条
[1]   Registry of emergency airways arriving at combat hospitals [J].
Adams, Bruce D. ;
Cuniowski, Peter A. ;
Muck, Andrew ;
De Lorenzo, Robert A. .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 64 (06) :1548-1554
[2]   Survey of out-of-hospital emergency intubations in the French prehospital medical system: A multicenter study [J].
Adnet, F ;
Jouriles, NJ ;
Le Toumelin, P ;
Hennequin, B ;
Taillandier, G ;
Rayeh, F ;
Couvreur, J ;
Nougiere, B ;
Nadiras, P ;
Ladka, A ;
Fleury, M .
ANNALS OF EMERGENCY MEDICINE, 1998, 32 (04) :454-460
[3]   Practice Guidelines for Management of the Difficult Airway An Updated Report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway [J].
Apfelbaum J.L. ;
Hagberg C.A. ;
Caplan R.A. ;
Connis R.T. ;
Nickinovich D.G. ;
Benumof J.L. ;
Berry F.A. ;
Blitt C.D. ;
Bode R.H. ;
Cheney F.W. ;
Guidry O.F. ;
Ovassapian A. .
ANESTHESIOLOGY, 2013, 118 (02) :251-270
[4]  
[Anonymous], ADV TRAUMA LIFE SUPP
[5]  
[Anonymous], EMERG MED J
[6]  
[Anonymous], AIR MED J
[7]   A comparison of a new indicator-guided with a conventional wire-guided percutaneous cricothyroidotomy device in mannequins [J].
Assmann, Nicole M. ;
Wong, David T. ;
Morales, Eduardo .
ANESTHESIA AND ANALGESIA, 2007, 105 (01) :148-154
[8]   Cricothyrotomy: A 5-year experience at one institution [J].
Bair, AE ;
Panacek, EA ;
Wisner, DH ;
Bales, R ;
Sakles, JC .
JOURNAL OF EMERGENCY MEDICINE, 2003, 24 (02) :151-156
[9]   A comparison of a novel cricothyrotomy device with a standard surgical cricothyrotomy technique [J].
Bair, AE ;
Sakles, JC .
ACADEMIC EMERGENCY MEDICINE, 1999, 6 (11) :1172-1174
[10]   A comparison of two emergency cricothyroidotomy kits in human cadavers [J].
Benkhadra, Mehdi ;
Lenfant, Francois ;
Nemetz, Wolfgang ;
Anderhuber, Friedrich ;
Feigl, Georg ;
Fasel, Jean .
ANESTHESIA AND ANALGESIA, 2008, 106 (01) :182-185