Measuring corrosion rate of rebars in reinforced concrete is essential for establishing service life prediction of structures and controlling the efficiancy of repair methods. Different electrochemical techniques, all based on measuring the polarization resistance, are used in the laboratory and on site, In calculating corrosion rate from the experimentally determined Rp value, two main problems arise: current distribution between the small counter elelctrode and the rebars on real structures and localized corrosion attacks. In this work results from laboratory experiments on macrocell corrosion are presented, showing the influence of resistivity and geometrical arrangement on the macrocell corrosion rate under open circuit conditions and under an external anodic pulse. From the results it can be concluded that the polrization resistance measured experimentally corresponds to the corrosion rate of the anode in the macrocell, Most of the imposed current is flowing to the local anode and thus signal confinement for local corrosion attacks is not necessary. The segmented counter electrode opens a way to determined localized corrosion rates.
引用
收藏
页码:127 / 137
页数:11
相关论文
共 50 条
  • [41] Reliability of Galvanostatic Pulse Technique in assessing the corrosion rate of rebar in concrete structures: Laboratory vs field studies
    Vedalakshmi, R.
    Balamurugan, L.
    Saraswathy, V.
    Kim, S. -H.
    Ann, K. Y.
    KSCE JOURNAL OF CIVIL ENGINEERING, 2010, 14 (06) : 867 - 877
  • [42] Reliability of Galvanostatic Pulse Technique in assessing the corrosion rate of rebar in concrete structures: Laboratory vs field studies
    R. Vedalakshmi
    L. Balamurugan
    V. Saraswathy
    S. -H. Kim
    K. Y. Ann
    KSCE Journal of Civil Engineering, 2010, 14 : 867 - 877
  • [43] Formulation of a Nondestructive Technique for Evaluating Steel Corrosion in Concrete Structures
    Lim, Young-Chul
    Noguchi, Takafumi
    Shin, Sung-Woo
    ISIJ INTERNATIONAL, 2009, 49 (02) : 275 - 283
  • [44] Corrosion rate of steel in concrete - Measurements beyond the Tafel law
    Elsener, B
    CORROSION SCIENCE, 2005, 47 (12) : 3019 - 3033
  • [45] Environmental influence on the corrosion rate of steel bars embedded in concrete
    Yokota, Masaru
    Kyung, Je-Woon
    Lee, Han-Seung
    ISIJ INTERNATIONAL, 2008, 48 (02) : 230 - 234
  • [46] Field and laboratory experience with electrochemical methods for assessing corrosion of steel in concrete
    Videm, K
    ELECTROCHEMICAL METHODS IN CORROSION RESEARCH VI, PTS 1 AND 2, 1998, 289-2 : 3 - 14
  • [47] Long-term performance of galvanic anodes for the protection of steel reinforced concrete structures
    Kamde, Deepak K.
    Manickam, Karthikeyan
    Pillai, Radhakrishna G.
    Sergi, George
    JOURNAL OF BUILDING ENGINEERING, 2021, 42
  • [48] A review on corrosion detection and protection of existing reinforced concrete (RC) structures
    Hu, J. Y.
    Zhang, S. S.
    Chen, E.
    Li, W. G.
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 325
  • [49] Proposal of method monitoring macrocell corrosion rate at existing reinforced concrete
    Hiraishi, Yoichi
    Miyazato, Shinichi
    Umino, Norihiko
    Fujimoto, Kazuo
    Zairyo/Journal of the Society of Materials Science, Japan, 2008, 57 (05) : 502 - 508
  • [50] Use of the time constant to detect corrosion speed in reinforced concrete structures
    Birbilis, N.
    Holloway, L. J.
    CEMENT & CONCRETE COMPOSITES, 2007, 29 (04) : 330 - 336