Corrosion rate of steel in concrete - From laboratory to reinforced structures

被引:4
|
作者
Elsener, B
机构
来源
ELECTROCHEMICAL METHODS IN CORROSION: RESEARCH AND APPLICATION | 1997年 / 247卷
关键词
corrosion rate; polarization resistance; localized corrosion; current distribution; macrocell; galvanostatic pulse; monitoring;
D O I
10.4028/www.scientific.net/MSF.247.127
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Measuring corrosion rate of rebars in reinforced concrete is essential for establishing service life prediction of structures and controlling the efficiancy of repair methods. Different electrochemical techniques, all based on measuring the polarization resistance, are used in the laboratory and on site, In calculating corrosion rate from the experimentally determined Rp value, two main problems arise: current distribution between the small counter elelctrode and the rebars on real structures and localized corrosion attacks. In this work results from laboratory experiments on macrocell corrosion are presented, showing the influence of resistivity and geometrical arrangement on the macrocell corrosion rate under open circuit conditions and under an external anodic pulse. From the results it can be concluded that the polrization resistance measured experimentally corresponds to the corrosion rate of the anode in the macrocell, Most of the imposed current is flowing to the local anode and thus signal confinement for local corrosion attacks is not necessary. The segmented counter electrode opens a way to determined localized corrosion rates.
引用
收藏
页码:127 / 137
页数:11
相关论文
共 50 条
  • [21] Influences of Concrete Resistivity on Corrosion Rate of Steel Bar in Concrete
    Huang, Zhonghui
    Yu, Bo
    Yang, Lu-feng
    Wu, Ming
    CIVIL ENGINEERING, ARCHITECTURE AND SUSTAINABLE INFRASTRUCTURE II, PTS 1 AND 2, 2013, 438-439 : 349 - 352
  • [22] Non-destructive data assimilation as a tool to diagnose corrosion rate in reinforced concrete structures
    Anterrieu, Olivier
    Giroux, Bernard
    Gloaguen, Erwan
    Carde, Christophe
    JOURNAL OF BUILDING ENGINEERING, 2019, 23 : 193 - 206
  • [23] Approach to consider self-corrosion in corrosion monitoring of reinforced concrete structures exposed to chlorides
    Fraundorfer, Andreas
    Dauberschmidt, Christoph
    Gehlen, Christoph
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2024, 75 (04): : 516 - 528
  • [24] Estimation of rebar corrosion rate in reinforced concrete structure
    Cho, SH
    Chung, L
    Roh, YS
    CORROSION REVIEWS, 2005, 23 (4-6) : 329 - 353
  • [25] Influence of Crack Spacing on Corrosion Rate in Reinforced Concrete
    Bezuidenhout, S. R.
    van Zijl, G. P. A. G.
    HIGH TECH CONCRETE: WHERE TECHNOLOGY AND ENGINEERING MEET, 2018, : 2109 - 2117
  • [26] Development of an optical pH sensor for early detection of danger of corrosion in steel-reinforced concrete structures
    Dantan, Nathalie
    Hoehse, Marek
    Karasyov, Alexander A.
    Wolfbeis, Otto S.
    TM-TECHNISCHES MESSEN, 2007, 74 (04) : 211 - 216
  • [27] Laboratory studies on influence of transverse cracking on chloride induced corrosion rate in concrete
    Ji, Yongsheng
    Hu, Yijie
    Zhang, Linglei
    Bao, Zhongzheng
    CEMENT & CONCRETE COMPOSITES, 2016, 69 : 28 - 37
  • [28] Fiber optic pH sensor for early detection of danger of corrosion in steel-reinforced concrete structures
    Dantan, N
    Habel, WR
    Wolfbeis, OS
    SMART STRUCTURES AND MATERIALS 2005: SMART SENSOR TECHNOLOGY AND MEASUREMENT SYSTEMS, 2005, 5758 : 274 - 284
  • [29] Effect of Steel Bar Corrosion Inhibitors in Carbonated Reinforced Concrete
    Guo Q.
    Li X.
    Song Y.
    Liu J.
    Jianzhu Cailiao Xuebao/Journal of Building Materials, 2023, 26 (01): : 21 - 28
  • [30] Corrosion rate of steel reinforcements after carbonation of concrete
    Yonezawa, Toshio, 1600, Architectural Institute of Japan (79): : 1405 - 1414